E-6
DuraStor 412R/6320SS/7320SS Installation and User’s Guide
DuraStor 7320SS Storage Subsystem
Operating Environment
Operating
Non-Operating
+40
°
F to +95
°
F (+5
°
C to +35
°
C)
–4
°
F to +158
°
F (-20
°
C to +70
°
C)
Relative Humidity
Operating/Non-Operating
5% – 95% (non-condensing)
Power Requirements
100 – 240 VAC (auto-sensing)
3.0 Amperes (maximum)
50-60 Hz
2 x 350 Watts
Dimensions (HxWxD)
3.47" x 17.65" x 20.25"
Weight (w/2 power supplies)
38.55 lbs without drives
58.00 lbs with twelve drives
Altitude
-200 to 10,000 feet
Number of Drives Supported
12 per enclosure
Total Capacity
876 gigabytes (73 GB drives)
Host Interface
FC-AL (Fibre Channel Arbitrated
Loop
Drive Interface
SCA-80 Ultra320/160 SCSI
I/O Interface
RS-232 (Power Supply,
Temperature, and Fan
monitoring)
Electromagnetic Emissions
Requirements (EMI)
FCC, Part 15, Class A
CISPR 22 EN55022-A
VCCI, BSMI, C-TICK
Safety Requirements
ANSI/UL60950
CSA #950
CE Compliance (EMC)
89/336/EEC EMC Directive
Shock
Operating
Non-Operating
1.0 G, 2 – 50 ms
20.0 G, 2 – 20ms
Vibration
Operating
Non-Operating
5 – 500 Hz, 0.25 G (pk to pk)
5 – 500 Hz, 1.0 G (pk to pk)
DuraStor IUG - Online.book Page 6 Friday, July 19, 2002 3:06 PM