background image

 

 

 

Adam Equipment 

 

 

 

GBK Mplus / GFK Mplus Series 

 

 

 

 

 

 

 

 

 

 

Содержание GBK 150Mplus

Страница 1: ...Adam Equipment GBK Mplus GFK Mplus Series...

Страница 2: ...Easy Reference Model name of the scale Serial number of the unit Software revision number Displayed when power is first turned on Date of Purchase Name of the supplier and place...

Страница 3: ......

Страница 4: ...CHECK WEIGHING 18 10 5 1 SETTING UP WHILE WEIGHING 19 10 5 2 SETTING UP WHILE PARTS COUNTING OR WEIGHING 19 10 6 LIMITS STORING AND RECALLING 20 10 7 PERCENT WEIGHING 21 10 8 1 ANIMAL WEIGHING PROCED...

Страница 5: ...ith an audible alarm for check weighing The GBK GFK Mplus scales are supplied with a RS 232 bi directional interface and real time clock RTC The GBK GFK has a sealed keypad with colour coded buttons a...

Страница 6: ...typical Operating Temperature 10 C to 40 C 14 F to 104 F Power Supply 110V 240 VAC 50 60 Hz Calibration External Display 6 digits LCD digital displays with capacity tracker and symbols for units Pan...

Страница 7: ...g Temperature 10 C to 40 C 14 F to 104 F Power Supply 110V 240 VAC 50 60 Hz Calibration External Display 6 digits LCD digital displays with capacity tracker and symbols for units Pan Size 400mm x 500m...

Страница 8: ...ce in direct sunlight or near air conditioning vents Avoid unsuitable tables The table or floor must be rigid and not vibrate Avoid unstable power sources Do not use near large users of electricity su...

Страница 9: ...justing the four feet If the scale rocks re adjust the feet Attach the indicator module to the pillar by sliding it over the bracket with the flanges engaged in the groves on the base Attach the cable...

Страница 10: ...a tare value subtracts the tare value from the weight and shows the results This is the net weight Accept the set values Unit This is used to select the weighing units from a preset list of available...

Страница 11: ...select percent weighing RS 232 parameters Operation of the bar graph RTC settings User ID and Scale ID None Cnt Enter Parts Counting None Print It is used to print the results to a PC or printer usin...

Страница 12: ...for the units Capacity Tracker A bar graph indicating the proportion of the scale capacity being used by the weight on the platform Battery status The scale is in Percent weighing mode pcs The scale...

Страница 13: ...increment until the display can no longer hold the values 1 to 999999 It is expected we will never have more than 1 million calibrations in the life of the machine Each display is held for 1 2 seconds...

Страница 14: ...the backlight can also be defined there are three settings to choose from Low Mid and High 9 0 AUTO POWER OFF The auto power off can be set by the user to disable the feature or to a pre set time int...

Страница 15: ...e weight of the product will be shown The scale could be tared a second time if another type of product was to be added to the first one Again only the weight that is added after taring will be displa...

Страница 16: ...The scale can be used to count parts based on the average weight of a sample weighed When more parts are added the total number of parts are displayed If a container is to be used place this containe...

Страница 17: ...more than the resolution of the scale After the sample has been weighed the scale will count any other parts added by applying the average piece weight to the weight of the parts to be counted The Tar...

Страница 18: ...ory holds values for a high limit and a low limit Either or both the limits can be set by the user NOTE 1 The alarm can be set to OFF See section 13 1 The LCD display will indicate whenever the weight...

Страница 19: ...igh limit the HI symbol will be on to the left side of the display Set the high limit in the same way the low limit was set Pressing the Tare key to enter the value will return the scale to weighing w...

Страница 20: ...StOrE and rECALL If you want to store the limits when StOrE is displayed press the Tare key The display shows St Enter a number corresponding to the desired memory location 0 to 9 St X will be displa...

Страница 21: ...l use a mass on the platform as the 100 reference weight If the platform is empty or the scale is tared then the user can input a reference weight using the keypad If using a reference weight or objec...

Страница 22: ...showing zero weight before entering this function then the user must manually enter the weight to be set as 100 When F4 PCT is displayed enter the weight to be used for the 100 reference then press T...

Страница 23: ...to advance to the second function P2 Ani Animal weighing Press Tare to enter the animal weighing function To use the Animal Weighing function it is necessary to set the amount of filtering required f...

Страница 24: ...will flash Ani twice and be ready for the next animal To weigh a second animal press the Tare key if necessary to zero the display and place the next animal on the scale It is also possible to simply...

Страница 25: ...e a second weight on the platform When stable press Print to accumulate the weight The display will show ACC 2 for 2 seconds and then show the new total Continue until all weights have been added This...

Страница 26: ...al in the memory before it returns to zero Adding a 2nd weight will repeat the process While the weight is on the platform press the Print key to view the values first the accumulation number ACC x an...

Страница 27: ...weight with the selected weighing unit through the RS 232 interface Default Specifications Connector The scale can be set to print text in English French German Spanish Italian or Portuguese See the...

Страница 28: ...and number of parts are printed cr lf cr lf Date 12 09 2006 cr lf Time 14 56 27 cr lf cr lf Scale ID 123456 cr lf User ID 234567 cr lf cr lf Net Wt 1 234 kg cr lf Net Wt or Gross Wt Unit Wt 123 g cr l...

Страница 29: ...ut Parts Counting cr lf Date 12 09 2006 cr lf Time 14 56 27 cr lf cr lf Scale ID 123456 cr lf User ID 234567 cr lf cr lf cr lf TOTAL No 5 cr lf Wt 1 234 kg cr lf PCS 10 pcs cr lf cr lf cr lf cr lf Net...

Страница 30: ...ortuguese Net weight Net Wt Pds Net Net Gew Pso Net Pso Netto Pso Liq Weight per unit counted Unit Wt Pds unit Gew Einh Pso Unid Pso Unit Pso Unid Number of items counted Pcs Pcs Stck Piezas Pezzi Pec...

Страница 31: ...play shows zero P cr lf Prints the results to a PC or printer using the RS 232 interface It also adds the value to the accumulation memory if the accumulation function is not set to automatic 12 0 CAL...

Страница 32: ...press the Func key to advance through the groups FUnC 1 FUnC 2 FUnC 3 and FUnC 4 Press Tare to enter the desired group of parameters Press Zero to return to the group FUnC 1 If you press Zero again t...

Страница 33: ...P This parameter sets the Beeper for the Keypad Kp and for the Check weighing Ck If Ck is set to on the beeper can further be set to sound when the weighing result is within or outside the check weigh...

Страница 34: ...n advance to the next parameter by pressing the Func key Press Zero to return to the group FUnC 2 If you press Zero again the scale will exit the User Parameter section and return to weighing This gro...

Страница 35: ...nglish FrEnCH French SPAn Spanish GErmAn German iTALi Italian PortuG Portuguese EnGLi C6 UId Set User ID To be entered manually 000000 C7 Sid Set Scale ID To be entered manually 000000 C8 LAb Label re...

Страница 36: ...xit the User Parameter section and return to normal weighing This group of parameters are used to control the operation of the scale Parameter Description Options Default setting S1 Un Enable or disab...

Страница 37: ...onE PI _ _ _ _ 0000 S8 dot Decimal place separator settings Sets the separator for decimal places as dot or comma dot S9 AZ Auto Zero settings oFF 0 25 0 5 0 5 S10 rE Battery recharging status Shows t...

Страница 38: ...r 5 Press button to zero and zero when power on Scale already zeroed with no mass on weighing pan Err 6 Can t Tare for negative weight Weight on weighing pan below zero Err 7 Can t wait until stable S...

Страница 39: ...is damaged Electronics is damaged OL Weight over range Weight over scale range undEr Weight is lower than 25e Weight below scale range 15 0 REPLACEMENT PARTS AND ACCESSORIES If you need to order any s...

Страница 40: ...methods B Details of the unit purchased This part of information should always be available for any future correspondence We suggest you to fill in this form as soon as the unit is received and keep...

Страница 41: ...nal packaging and with correct documentation for a claim to be processed All claims are at the sole discretion of Adam Equipment This warranty does not cover equipment where defects or poor performanc...

Страница 42: ...Printing Mode MA StA Manual Au StA Automatic Au Con Continuous C4 Aon Enable Accumulation on oFF C5 Ln Language for printing EnGLiS English FrEnCH French SPAn Spanish GErMAn German itALi Italian Port...

Страница 43: ...ercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio...

Страница 44: ...Phone 49 0 4340 40300 0 Fax 49 0 4340 40300 20 e mail vertrieb aeadam de Adam Equipment S A Pty Ltd 7 Megawatt Road Spartan EXT 22 Kempton Park Johannesburg Republic of South Africa Phone 27 0 11 974...

Отзывы: