ACV SMART Line Series Скачать руководство пользователя страница 1

A1003499 - 661Y2000 • C

EN

FR

NL

ES

IT

DE

PL

RU

INSTALLATION, OPERATION AND

MAINTENANCE INSTRUCTIONS, 

for the User and the Installer

Smart ME

200 - 300 - 400 - 600 - 800

SMART Line

Содержание SMART Line Series

Страница 1: ...A1003499 661Y2000 C EN FR NL ES IT DE PL RU INSTALLATION OPERATION AND MAINTENANCE INSTRUCTIONS for the User and the Installer Smart ME 200 300 400 600 800 SMART Line...

Страница 2: ...300 10 Dimensions Smart ME 200 300 11 Main characteristics Smart ME 400 600 800 12 Dimensions Smart ME 400 600 800 13 Heating connections 14 Domestic hot water connections 16 Domestic hot water perfo...

Страница 3: ...ible combinations of the Smart ME 33 Smart ME tank used as electric DHW tank only 34 STARTING UP 35 Safety instructions to fill the tank 35 Filling 36 Checks before starting up 38 Starting up 38 MAINT...

Страница 4: ...maintenance contractor every year In case of anomaly please call your installer for advice Faulty parts may only be replaced by genuine parts Our water heaters are designed and manufactured for the ex...

Страница 5: ...en 5 Smart ME A1003499 661Y2000 C EN FR NL ES IT DE PL RU PRODUCT INFORMATION ENERGY LABELLING...

Страница 6: ...en 6 Smart ME A1003499 661Y2000 C EN NL ES IT DE PL RU FR PRODUCT INFORMATION RATING PLATE Smart ME 120 Smart ME 600 800 Smart ME 200 Smart ME 300 400...

Страница 7: ...00 Key 1 Control thermostat 60 80 C to set the domestic hot water DHW temperature 2 Manual reset high limit thermostat to restart the tank after overheating of the primary circuit 3 Connection plug to...

Страница 8: ...ANCE DESCRIPTION Smart ME 200 MODELS Smart ME 200 300 400 600 800 High efficiency storage water tanks multi energy type to be installed on the floor Possibility to heat by coil by heat transfer fluid...

Страница 9: ...valve 2 Polyurethane foam insulation 3 Polypropylene shell 4 Dip tube 5 Electrical heating element optional 6 Polypropylene top lid 7 Stainless steel tank DHW 8 Dry well 9 Outer steel tank primary ci...

Страница 10: ...ary pressure drop mbar 41 6 51 2 Coil pressure drop mbar 460 533 Tank heating surface m 1 26 1 46 Coil heating surface m 1 42 1 80 Max Design Pressure bar 10 10 Reheat Performance Primary Heating Powe...

Страница 11: ...61Y2000 C EN FR NL ES IT DE PL RU TECHNICAL CHARACTERISTICS DIMENSIONS SMART ME 200 300 Smart ME 200 565 360 150 245 80 120 525 1500 540 235 305 95 300 300 Smart ME 300 250 255 145 350 300 240 80 120...

Страница 12: ...58 5 Coil pressure drop mbar 533 186 216 Tank heating surface m 1 94 1 90 2 65 Coil heating surface m 1 80 2 50 3 00 Max Design Pressure bar 10 10 10 Reheat Performance Primary Heating Power Input kW...

Страница 13: ...ECHNICAL CHARACTERISTICS DIMENSIONS SMART ME 400 600 800 Smart ME 400 520 240 80 120 1950 250 280 520 120 600 400 675 360 150 230 80 180 570 Smart ME 600 1890 610 240 330 145 538 320 700 270 910 340 8...

Страница 14: ...7 Sensor pocket coil 8 Sensor pocket lowest temperature tank 9 Optional electrical heating element connection 10 Attachment point for hydraulic kit optional Connections dimensions Models Heating conn...

Страница 15: ...en 15 Smart ME A1003499 661Y2000 C EN FR NL ES IT DE PL RU TECHNICAL CHARACTERISTICS Smart ME 600 Smart ME 800 10 3 4 5 6 9 1 2 2 8 5 6 7 10 3 4 5 6 1 2 2 8 5 6 7...

Страница 16: ...ection 2 Auxiliary connection DHW 3 Domestic hot water connection Pipe dimensions Models Cold hot water connections Auxiliary connections Smart ME 200 3 4 M 3 4 M Smart ME 300 3 4 M 3 4 M Smart ME 400...

Страница 17: ...1167 1450 60 C T 50K L 60 333 402 536 661 808 Maximum absorbed power kW 16 19 25 29 35 DHW performance Heating source External boiler connected to tank Smart ME 200 300 400 600 800 Peak flow at 40 C T...

Страница 18: ...andle temperatures of 99 C or greater should be used Extract from The Building Regulation G3 Discharge pipe D1 3 50 Safety devices such as temperature relief valves or combined temperature and pressur...

Страница 19: ...er discharged in which case it should a contain a mechanical seal not incorporating a water trap which allows water into the branch pipe without allowing foul air from the drain to be ventilated throu...

Страница 20: ...3 61 gives alternative points of discharge Fixed grating Trapped gulley Valve outlet size Minimum size of discharge pipe D1 Minimum size of discharge pipe D2 from tundish Maximum resistance allowed ex...

Страница 21: ...5 8m is less than the actual length of 7m therefore calculates the next largest size Maximum resistance allowed for a straight length of 28mm pipe D2 from a G1 2 temperature relief valves equates to 1...

Страница 22: ...the heating element To be mounted with an external box with a switch and a circuit breaker not included in the delivery Volt Amp Power Code 1 x 230 V 13 3 kW 10800081 3 x 400 V N 4 4 3 kW 10800082 1 x...

Страница 23: ...rmostat 60 80 C Bk Black Br Brown Or Orange R Red W White Y Gr Yellow Green Optional kit thermostat Smart ME 600 800 10800260 B Blue Br Brown Y Gr Yellow Green 1 Control thermostat 60 80 C 2 Thermomet...

Страница 24: ...ct reception and after removal of packaging check the package contents and that the appliance is free of damages Contents packaging N 1 A domestic hot water tank Smart ME A multilingual Installation o...

Страница 25: ...LATION TOOLS REQUIRED FOR THE INSTALLATION For installation of the soft casing refer to Preparation of the Tank Smart ME 600 800 page 28 General remark Make sure to place the rating plate on the outer...

Страница 26: ...the earth Make sure to install a pressure reducing valve set at 4 5 bar in the DHW circuit if the supply pressure is higher than 6 bar On the DHW circuit install an approved safety group comprised of...

Страница 27: ...developing bacteria exists including Legionella pneumophila if a minimum temperature of 60 C is not maintained in both the DHW tank and the hot water distribution network Essential instructions for th...

Страница 28: ...en 28 Smart ME A1003499 661Y2000 C EN NL ES IT DE PL RU FR INSTALLATION PREPARATION OF THE TANK SMART ME 600 800...

Страница 29: ...en 29 Smart ME A1003499 661Y2000 C EN FR NL ES IT DE PL RU INSTALLATION Install the rating plate sticker here...

Страница 30: ...te size Make sure that the circuit between the tank and the safety valve is always open The third DHW tank connection if any can be used for the auxiliary DHW loop If the connection is not used replac...

Страница 31: ...ixing valve 12 Air vent Cold water Hot water Domestic hot water kit option not usable for the Smart ME 800 1 Thermostatic mixing valve 2 Mixed water outlet 3 4 M 3 DHW expansion vessel connection 3 4...

Страница 32: ...R INSTALLATION CONNECTION TO THE PRIMARY CIRCUIT 1 Primary circuit filling valve 2 Charging pump 3 Check valve 4 Primary circuit stop valve 5 Expansion vessel 6 Pressure gauge 7 Safety valve set at 3...

Страница 33: ...0 C EN FR NL ES IT DE PL RU INSTALLATION EXAMPLES OF DIFFERENT POSSIBLE COMBINATIONS OF THE SMART ME Smart ME combined with a heat pump solar panels and floor heating system Smart ME combined with a b...

Страница 34: ...the outside tank is not filled and bled 1 System filling valve 2 Safety valve set to 3 bar 3 Expansion vessel 4 Isolating valve heating system 5 Pressure gauge Essential instruction for the correct op...

Страница 35: ...ommended in the local regulations Consult the manufacturer to determine the compatibility of the antifreeze with the tank s construction materials Essential instructions for the correct operation of t...

Страница 36: ...r 3 Open the air bleed valve 4 located on the top of the hot water tank 4 When the air is eliminated close the air bleed valve 4 Make sure the air bleed valve is tight FILLING Essential instruction fo...

Страница 37: ...en 37 Smart ME A1003499 661Y2000 C EN FR NL ES IT DE PL RU STARTING UP Cold water Hot water Figure 1 1 3 3 2 Figure 2 1 2 4 3 2...

Страница 38: ...NG UP To put the installation into service refer to the heating boiler manual en 38 Smart ME A1003499 661Y2000 C EN NL ES IT DE PL RU FR STARTING UP STARTING UP If the tank is used as electric DHW tan...

Страница 39: ...iodically it may be due to an expansion problem or clogging of the valve For internal inspections the hand hole can be used If there is none use one of the water connections to insert the appropriate...

Страница 40: ...imary circuit of the hot water heater 1 Stop the charging pump 2 Isolate the primary circuit by closing the stop valves 1 3 Connect the drain valve 2 to the sewer using a flexible hose 4 Open the drai...

Страница 41: ...3 Connect the drain valve 2 to the sewer using a flexible hose 4 Open the drain valve 2 and the air vent 5 to drain the water from the DHW tank to the sewer 5 Close the drain valve 2 and the air vent...

Страница 42: ...ing pump works properly and replace if necessary 4 Check the safety thermostat on the tank and or the electric heating element and reset or replace if necessary 5 Check the electric heating element an...