ELECTRICAL CHARACTERISTICS - 25 TO 45 KW EVO APPLIANCES
230 VAC OUTPUT !
230 VAC OUTPUT !
Key
1.
230 V power supply
2.
Ground
3.
ON/OFF master switch
4.
Gas valve rectified
5.
Burner power supply
6.
Terminal block for optional items
: Alarm (ERR)
: DHW circuit circulator pump (DHW)
7. Terminal block for optional items:
: Pump (P3 and P4 terminals)
: Flame terminal (versatile connection according to configuration)
8.
Modulating pump PWM
9.
Burner PWM plug
10.
NTC5 flue gas temperature sensor
11.
NTC2 return sensor
12.
NTC1 supply sensor
13.
NTC - Low temperature circuit
14.
High limit switch
15.
Low water pressure sensor
16.
PCB (Display)
17. ACVMax programmation plug
18.
A & B Modbus (option)
19.
NTC3 DHW sensor
20. NTC4 outdoor temperature sensor (option)
21.
Room thermostat 1 (option)
22. 0-10 Volt (option)
23. Room thermostat 2 (option)
24. Connection for interface control unit
25. Ignition and ionization cable
26. 5AT slow-blow fuse (3x) for internal and optional circuits*
27. 10A fuse, 250V, Dim: 5x20 mm
* 5AT slow-blow fuse (2x) for internal circuits and connection of CH, DHW and Flame 5AT slow-blow fuse (1x) for con-
nection of Alarm, P3 and P4 (connector P14)
2 spare 5AT slow-blow fuses are located on the back side of the electrical box, for fuse replacement, if required.
HeatMaster (T)C Evo
Main Characteristics
25
35
45
Rated voltage
V~
230
230
230
Rated frequency
Hz
50
50
50
Electrical consumption
Max.
W
95
111
126
Min.
W
19
30
40
Electrical consumption
at 30% load
W
24
34
45
Electrical consumption
in standby
W
3
3
3
Rated current (Fuse)
A
16
16
16
Class
IP 20
IP 20
IP 20
WaterMaster Evo
Main Characteristics
25(X)
35
45(X)
Rated voltage
V~
230
230
230
Rated frequency
Hz
50
50
50
Electrical consumption
Max.
W
95
110
126
Min.
W
19
30
40
Electrical consumption at
30% load
W
24
34
45
Electrical consumption in
standby
W
3
3
3
Rated current (Fuse)
A
16
16
16
Class