![Acuity AccuRange AR500 Скачать руководство пользователя страница 16](http://html1.mh-extra.com/html/acuity/accurange-ar500/accurange-ar500_user-manual_2844429016.webp)
AR500 User’s Manual
LLL00xxxx – Rev 1.0
9
4.
Signal and Power Interface
4.1
Sensor Cable, Wire Colors and Functions
The AR500 sensor includes a multipurpose cable (sensor cable) with solder tail
wires. Connection and termination according to the instructions is essential
for correct sensor operation. Read the wire descriptions for connection
information.
7
1
2
3
4
8
6
5
Figure 2 AR500 cable with 8 conductors (Binder 712, #09-0427-80-08)
The tables below shows the wiring on systems ordered without power supplies.
Wire
Pin
Function in All Modes
White
1
Trigger Input
Brown
2
Ground (Power)
Green
3
TxD (Data +)
Yellow
4
RxD (Data -)
Gray
5
Ground (Signal common)
Pink
6
Logic Output (programmable)
Blue
7
Analog output (current loop / voltage)
Red
8
Power, Voltage in
4.2
Power Supply (Red, Brown)
The Brown wire is the Power Supply Common return, also named Ground. It
carries the return current for the power supply.
The Red wire is the Power Supply Input to the sensor. The sensor re9
- 36 VDC power and consumes 1.5 – 2 Watts of power (< 250mA draw)
depending on the sensor’s configuration.
Power supplies from 9 VDC to 36 VDC may be used. Higher voltages will
result in excessive current drawn by the over-voltage protection circuitry and
may cause permanent damage. Voltages less than 9 VDC may result in
inaccurate measurement readings or non-functionality.
4.3
RS232 / RS485 Serial Comm. (Green, Yellow)
Your sensor is configured with either RS232 or RS485 communications