background image

 
 

Page 

1

 of 

1

 

 

IMPORTANT SAFETY INSTRUCTIONS 

LOWERING DEVICES 

 

 

 
 
 
 
 

 

 
 

 

To reduce the risk of death, personal injury or property damage from fire, electric shock, falling parts, cuts/abrasions, and other 
hazards please read all warnings and instructions.  

 

Before installing, servicing, or performing routine maintenance upon this equipment, follow these general precautions. 

 

Installation and service of Lowering Devices should be performed by a 

qualified licensed electrician and mechanical technician

.  

 

Maintenance of the Lowering Devices should be performed by person(s) familiar with the Lowering Devices construction and 
operation and any hazards involved.   

 

DO NOT INSTALL DAMAGED PRODUCT!  

This Lowering Device has been properly packed so that no parts should have been 

damaged during transit. Inspect to confirm.  Any part damaged or broken during or after assembly should be replaced.

 

 

These instructions do not purport to cover all details or variations in equipment nor to provide every possible contingency to meet 
in connection with installation, operation, or maintenance.  Should further information be desired or should particular problems 
arise which are not covered sufficiently for the purchaser’s or owner’s purposes, this matter should be referred to Acuity Brands 
Lighting, Inc.  

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 
 
 
 
 

Failure to follow any of these instructions could void product warranties.   

For a complete listing of product Terms and Conditions, please visit www.acuitybrands.com. 

 
Our Brands

   

Indoor/Outdoor 

 

Indoor Lighting 

 

Outdoor Lighting 

 

Controls

 

 

 

Lithonia Lighting 

 

Gotham 

 

 

American Electric Lighting 

DARK TO LIGHT 

 

 

Carandini 

 

 

Mark Architectural Lighting 

Antique Street Lamps 

 

Lighting Control & Design 

 

 

Holophane   

 

Peerless 

 

 

Hydrel 

 

 

ROAM 

 

 

RELOC  

 

 

Renaissance Lighting 

 

Tersen 

 

 

Sensor Switch 

 

 

 

 

 

Winona Lighting 

 

 

 

 

Synergy 

 

Acuity Brands Lighting, Inc.  assumes no responsibility for claims arising out of improper or careless installation or handling of its products. 

 

© 2010 Acuity Brands Lighting, Inc. All rights reserved. 6/03/13     ABL General Warnings, Form No. 503.204 

 

READ AND FOLLOW ALL SAFETY INSTRUCTIONS! 

SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION 

 

 

Disconnect or turn off power before installation or servicing. 

 

Verify that supply voltage is correct by comparing it with the luminaire label information. 

 

Make all electrical and grounded connections in accordance with the National Electrical Code (NEC) and any applicable local 
code requirements. 

 

All wiring connections should be capped with UL approved recognized wire connectors. 

 
 
 

 

 

WARNING 

RISK OF ELECTRIC SHOCK 

 
 

 
 

 

 

Do not stand directly beneath the pole or lowering device during installation except as instructed to in this manual. 

 

Do not depend on the lowering device cables to tether a slip-fit type pole. Failure to use a tethering cable may result in injury 
or death. 

 

Operate the lowering device only while standing at the maximum distance from the pole allowed by the twenty foot long 
remote control cord. Failure to follow this procedure

 

may result in injury or death.  

 

Wear gloves, safety glasses, hardhats and safety shoes at all times when removing 

Lowering Devices 

from carton, installing, 

servicing or performing maintenance. 

 

Follow pole manufacture installation instruction. 

 

Follow luminaire manufacture installation instruction when attaching to the lowering device.  

 

Do not expose the torque limiter or shear pin to damaging elements or mistreatment such as sand, mud, salt spray or other 
conditions which could render either safety mechanism inoperable. Do not attempt to adjust the torque limiting clutch or 
replace the shear pin. If repairs are necessary, replace damaged

 

equipment with replacement components from Holophane. 

Failure to follow these warnings may result in injury or death. 

 

 

 
 
 

 

 

CAUTION 

RISK OF INJURY 

Содержание Holophane 25

Страница 1: ...ity Brands Lighting Inc assumes no responsibility for claims arising out of improper or careless installation or handling of its products 2010 Acuity Brands Lighting Inc All rights reserved 6 03 13 AB...

Страница 2: ...the manual number in the lower right corner of this page Less detailed information regarding installation operation and main tenance of Holophane Lowering Devices is available in VHS video format For...

Страница 3: ...ting and maintenance personnel must read and understand completely Sections III and IV 3 Additional copies of this manual are available from Holophane 4 To expedite information and service call 740 34...

Страница 4: ...ructions Section III Operating Instructions Section IV Maintenance Instructions 4 1 LUBRICATION 4 2 REPLACING THE WINCH CABLE 4 3 DRIVE MOTOR SHAFT REPLACEMENT 4 4 POWER CORD REPLACEMENT 4 5 LUMINAIRE...

Страница 5: ...unting ring assembly one per Power cord and ring junction box one per Clevis assembly with coiled hoisting cables one per Winch and winch mounting plate with circuit breaker enclosure one per Luminair...

Страница 6: ...GR1129 4...

Страница 7: ...2 2 3 Unpack the junction box with the main power cord and place near the top of pole Uncoil the power cord halfway down along the pole and back to the top Uncoil in a manner that will not leave the...

Страница 8: ...other 2 2 10 Securely fasten the compression clamp on the power cord just under the clevis plate The location of the clamp is not critical at this time The clamp will be repositioned after the pole is...

Страница 9: ...ter line of the winch drum 2 4 2 Attach the winch cable swivel fitting to the U shaped bail of the clevis Insert the swivel pin in the direction so that the head of the pin is on the side of the clevi...

Страница 10: ...s started through the fitting As the cable exits the plastic sealing plug will be forced out and may be discarded 2 4 7 Repeat the steps in paragraphs 2 4 4 through 2 4 6 5 for the remaining two cable...

Страница 11: ...the Pole top Assembly 2 5 1 If the device is equipped with a bumper ring instead of iris type guide arms proceed to paragraph 2 5 3 Otherwise attach both guide arm spring brack ets to the ring See Fi...

Страница 12: ...5 7 1 Punch a 7 8 hole in the cover at the dimple location and install the rubber grommet 2 5 7 2 Thread the lightning rod into the lightning rod bracket tightening securely 2 5 7 3 Make sure all the...

Страница 13: ...luminaires mount the FAA marker at any vacant luminaire mounting position Counterweight locations Mount counterweight at these locations for lowering devices with 2 3 and 4 luminaires IMPORTANT The co...

Страница 14: ...uts to AASHTO Standard Specifications for Structural Supports for Highway Signs Luminaires and Traffic Signals Fifth Edition 2009 Section 5 17 5 2 anchor bolt pretensioning 2 6 3 Reference the wiring...

Страница 15: ...e with luminaires is now ready to be raised to the top of the pole 2 8 3 Following the operating instructions of Section III raise the ring and luminaires to the top of the pole stopping just before t...

Страница 16: ...ight of luminaires the clevis with hoisting cables and power cord may rotate and twist a few turns due to the constructional stretch inherent in new cables With the device latched and the load off the...

Страница 17: ...SINGLE CIRCUIT WIRING DIAGRAMS 15 GR1164 GR1165 GR1166...

Страница 18: ...DOUBLE CIRCUIT WIRING DIAGRAMS 16 GR1167 GR1168...

Страница 19: ...VICE SHOULD READ COMPLETELY AND UNDERSTAND FULLY THESE INSTRUCTIONS BEFORE OPERATING THE DEVICE 3 0 General Comments 3 0 1 The drive motor is provided with a twenty foot long remote control cord and s...

Страница 20: ...t uncoil slack in the winch cable that could foul the cable when tightened 3 3 5 Turn off the circuit breaker 3 3 6 Disconnect the circuit breaker cord from the drive motor and connect it to the main...

Страница 21: ...imiter assembly may be removed from the winch as described in paragraphs 2 3 4 through 2 3 6 4 4 POWER CORD REPLACEMENT 4 4 1 Remove the handhole cover Turn the circuit breaker off Disconnect the plug...

Страница 22: ...n the circuit breaker 4 5 LUMINAIRE REMOVAL CAUTION If it is necessary to remove a luminaire or components of a luminaire that is mounted on the ring assembly make sure the luminaire or its components...

Страница 23: ...HOLOPHANE High Mast Lowering Devices SECTION V ATTACHMENTS 21...

Страница 24: ...IM 188 D 6 13 2013 Acuity Brands Inc Visit our web site at www holophane com Acuity Lighting Group Inc Field Service Department P O Box3004 Newark OH43058 3004 Printed in USA...