ActSafe PPS Скачать руководство пользователя страница 1

PPS

PORTABLE 

POWER SUPPLY

Disclaimer 

 A

About ActSafe

 B

Safety messages and warnings 

 

C

Product safety

 D

System description

 E

Pre-use inspection 

F

and connection

 

General safety  

G

operating guidelines

 

Set-up

 H

Trouble-shooting guide

 I

Performance

 J

Warranty terms  

K

Declaration of conformity

 L

Technical data

 M

PPS User Manual 

Rev 1-2015 ENG MASTER

Actsafe_Power_Supply_Manual_vAW_v3.indd   1

07/04/2015   14:14

Содержание PPS

Страница 1: ...D System description E Pre use inspection F and connection General safety G operating guidelines Set up H Trouble shooting guide I Performance J Warranty terms K Declaration of conformity L Technical data M PPS User Manual Rev 1 2015 ENG MASTER Actsafe_Power_Supply_Manual_vAW_v3 indd 1 07 04 2015 14 14 ...

Страница 2: ...y subsequent user of the ActSafe Portable Power Supply that ActSafe Systems AB and or the seller cannot be held liable or accountable for damages injuries or death resulting from the use of the ActSafe Portable Power Supply and makes no warranty either expressed or implied or otherwise beyond that expressed herein ActSafe Systems AB disclaims any liability in tort for damages or direct or conseque...

Страница 3: ...sfully used for installing fireworks at the top of the Eiffel Tower hostage rescues from pirates at sea and providing essential logistical support in offshore wind turbines ActSafe products are redefining the possibilities for work in a vertical environment Today as leaders in our field we set the standard that others follow We are completely committed to our customers and do our utmost to deliver...

Страница 4: ...highlighted throughout this manual using the signals danger caution recommendation and note DANGER CAUTION RECOMMENDATION Note Not following instructions or training methods may result in SERIOUS INJURY or DEATH Not following instructions or training methods may result in INJURY or DAMAGE TO PROPERTY Instructions and tips on how best to use the Power Supply Important information on the use of the ...

Страница 5: ...ace If subjected to misuse in any way as parts or components may have been damaged Do not Use the Power Supply to charge any batteries Open the Power Supply under any circumstances Use any parts that are not original supplied by ActSafe DANGER Read the manual carefully and ensure that you have understood its contents Not following these instructions carefully may result in serious injury or death ...

Страница 6: ...el This Power Supply is supplied with a machine rating label attached to the housing This label must not be removed Air vent Power output Power overheat indicator LED 220V Power cable ACC Power Supply cable Actsafe_Power_Supply_Manual_vAW_v3 indd 6 07 04 2015 14 14 ...

Страница 7: ...ll be replaced if damaged 3 Check housing of Power Supply for damage If damaged contact your ActSafe distributor for repairs Connecting Power Supply 1 Make sure the Power Supply is installed in a secure place 2 Connect the Power Supply cable between the Power Supply and Ascender 3 Connect the power cable to the socket and check if the led on the Power Supply switches on 4 Switch on the ACCII Ascen...

Страница 8: ... cover the Power Supply while in use risk of overheating Secure the Power Supply when working at height GENERAL SAFETY OPERATING GUIDELINES G Inspection intervals The ActSafe Portable Power Supply must be checked before and after every use and must be subject to at least one inspection per year National regulations may require more frequent inspections Actsafe_Power_Supply_Manual_vAW_v3 indd 8 07 ...

Страница 9: ...e Power Supply can easily be connected to a 220V socket The Power Supply must not be used connected to long power cables whilst moving the Ascender up and down the rope These illustrations are intended to be used only as an indication of the position of the Power Supply Please refer to the ACCII Manual for further details on the correct use of the ACCII Ascender Actsafe_Power_Supply_Manual_vAW_v3 ...

Страница 10: ...it Overheating due to bad ventilation Overheating of Ascender feel chassis Unplug other devices from the power circuit Check for damage to cables or for water and or humidity in close proximity of all power connections Ensure air vent is not covered Ensure that outside temperature is not too high Let Ascender cool down and perform lifting with more frequent cooling intervals No power to Power Supp...

Страница 11: ...ide panels of the Power Supply may become hot and should not be touched It is also advisable to wear protective gloves Note Once the Ascender Power Supply has overheated initially an extended cooling period is recommended to prevent an immediate recurrence ActSafe Portable Power Supply The Power Supply is a nearly unlimited source of power that enables you to carry out extensive lifting with ACCII...

Страница 12: ...customers who have the original sales invoice The warranty does not apply if A damage or defect has occurred due to physical breakage electrical faults external to the product water penetration of the product abuse or events of force majeure The product is modified maintained or repaired by a party not authorized by ActSafe The product is maintained and operated in ways other than as recommended b...

Страница 13: ...ort or based on a warranty arising out of or in connection with the use or performance of the product or any ActSafe supplied accessories which accompanies the product even if ActSafe has been advised of the possibility of such damages The customer agrees that repair or replacement as applicable under the warranty services described herein are the sole and exclusive remedies with respect to any br...

Страница 14: ... Date It is hereby is certified that the following product Description ID mark type ActSafe Power Supply for ACC II Serial Number Notified body if any Danish Technological Institute Id No 0396 EEC type certificate TI 14 MD 0419 is made according to DIRECTIVE 2006 42 EC DIRECTIVE 2004 108 EC DIRECTIVE 2006 95 EC Harmonised standards EN 61000 6 2 2005 EN 61000 6 3 2007 EN 60204 1 2006 EN 60335 1 201...

Страница 15: ... 48V DC 50 A Weight 8 kg Dimensions 42x24x16 cm Protection classification IP 55 Ascender cable length 3 m Mains cable length 2 2 m Total weight Case PPS 12 6 kg Case dimensions 44x57x22 cm Case protection classification IP 67 M Actsafe_Power_Supply_Manual_vAW_v3 indd 15 07 04 2015 14 14 ...

Страница 16: ...ActSafe Systems AB Sagbäcksvägen 13 SE 43731 Lindome Sweden T 46 31 65 56 60 E info actsafe se 2015 ActSafe Systems AB DISTRIBUTOR Actsafe_Power_Supply_Manual_vAW_v3 indd 16 07 04 2015 14 14 ...

Отзывы: