ActronAir MRE-035AS Скачать руководство пользователя страница 1

IMPORTANT NOTE:

Please read this manual carefully before installing or operating your new air conditioning unit and keep it near the unit for 
future reference.

That’s better. That’s Actron.

INSTALLATION MANUAL

Model Numbers:

Four-Way Mini Cassette

MRE-035AS
MRE-050AS

That’s better. That’s Actron.

Содержание MRE-035AS

Страница 1: ...lly before installing or operating your new air conditioning unit and keep it near the unit for future reference That s better That s Actron INSTALLATION MANUAL Model Numbers Four Way Mini Cassette MR...

Страница 2: ...ble of Contents Installation Manual 1 2 3 5 4 6 7 Safety Precautions 04 Installation Overview 06 Components 05 Indoor Unit Installation 07 Test Run 18 Drainpipe Installation 12 Panel Installation 17 W...

Страница 3: ...lled in accordance with national regulations Failure to observe a caution may result in injury or equipment damage CAUTION Note about Fluorinated Gases 1 This air conditioning unit contains fluorinate...

Страница 4: ...ds and panel covers are always firmly secured and not damaged 7 This appliance is not intended for use by young children or infirm persons unless they have been adequately supervised by a responsible...

Страница 5: ...se the equipment to fail Name Shape Quantity Indoor Unit Installation 1 Installation paper template 1 Refrigeration Fittings 2 Soundproof insulation sheath 1 Drainpipe Fittings 3 Outlet pipe sheath 1...

Страница 6: ...oor unit Install the drainpipe Install the front panel Perform a test run 3 1 8 7 2 6 4 5 Connect the Refrigerant Pipes Evacuate the Refrigeration System Connect the wires Refer to Multi Elite Install...

Страница 7: ...or unit on a structure that can sustain its weight If the structure is too weak the unit may fall causing personal injury unit and property damage or death Install the indoor unit at a height of more...

Страница 8: ...et the following specifications See Fig 4 2 Fig 4 2 Recommended Distances Between The Indoor Unit And The Ceiling Ceiling Floor Panel 1000 mm OR MORE AIRFLOW ALLOWANCE 2500 mm OR MORE AIRFLOW ALLOWANC...

Страница 9: ...Details Q A3 Panel 647 647 50 Gas side Liquid side Body 545 570 E parts box 523 570 Drain Hole for Service 4 x Screw Hole to Install Panel 4 x Installation Hanger 260 Wiring Connection Port 150 2x 170...

Страница 10: ...ast 1m on all sides The hole will be 60x60cm big Be sure to mark the areas where ceiling hook holes will be drilled 4 Indoor Unit Installation Four Way Mini Cassette Hang Indoor Unit Fig 4 3 CAUTION T...

Страница 11: ...drain pump and float switch If the unit is tilted against the direction of condensate flows the drainpipe side is raised the float switch may malfunction and cause water to leak NOTE FOR NEW HOME INST...

Страница 12: ...to frozen drain water DO NOT pull the drainpipe forcefully as this could cause it to disconnect Indoor Drainpipe Installation 0 53cm 10cm NOTE When connecting multiple drainpipes install the pipes as...

Страница 13: ...e make sure to avoid wires plumbing and other sensitive components 3 Using a 65 mm core drill drill a hole in the wall Make sure that the hole is drilled at a slight downward angle so that the outdoor...

Страница 14: ...e A C unit Indoor Unit Wiring WARNING Before performing any electrical or wiring work turn off the main power to the system 1 Prepare the cable for connection a You must first choose the right cable s...

Страница 15: ...UNCTION IF PROVIDED INSTALL FERRITE RING IN THE FIELD P1 CN110 S1 S TO OUTDOOR UNIT INDOOR CIRCUIT BOARD WATER LEVEL SWITCH INDOOR COIL OUTLET TEMPERATURE SENSOR T2B WIRED CONTROLLER WC 02 4 CORE SHIE...

Страница 16: ...our Way Mini Cassette Connecting Diagram OUTDOOR UNIT N L POWER SUPPLY SUGGESTED MINIMUM N INDOOR UNIT 2 CORE 14 0 20 0 44mm SHIELDED DATA CABLE WITH SHIELD WIRE CONNECTED TO EARTH TERMINAL 1mm 2 CORE...

Страница 17: ...he unit Attach the decoration panel to the unit with the supplied screws as shown in figure below Fig 7 3 After installing the decoration panel ensure that there is no space between the unit body and...

Страница 18: ...length of the piping and the added refrigerant stow capacity have been recorded i The power voltage is the correct voltage for the air conditioner Test Run Instructions 1 Open both the liquid and gas...

Страница 19: ...ment in order to maintain your system s proper operating performance High discharge pressures are good indication that the coils need cleaning When using detergent or solvents to clean the coils follo...

Страница 20: ...an 1M Heat Exchanger Check for clogging by dust Check for leaks damage Clean air inlet side as necessary Straighten any bent fins using fins comb Drain Pan Condensation line Check for obstructions fre...

Страница 21: ...water Clean to eliminate obstructions sludge check condition of drain line Pour water to ensure free flow Compressor Check for high low pressure Measure insulation resistance Check compressor for abn...

Страница 22: ...Page 22 Notes Four Way Mini Cassette...

Страница 23: ...Page 23 Notes Four Way Mini Cassette...

Страница 24: ...onair com au 1300 522 722 Copyright 2017 Actron Engineering Pty Limited ABN 34 002 767 240 Registered Trade Marks of Actron Engineering Pty Limited Installation Document 9590 5005 Ver 3 Issue Date 03...

Отзывы: