ACTiSYS ACT-IR100UD-MDT Скачать руководство пользователя страница 24

 

The Infrared Wireless Expert 

ACT-IR100UD-MDT

User Manual

 

©

 Copyright 2007-2010 ACTiSYS Corp. 

Confidential Information

 

24 of 25 

Sep. 3, 2010 

Ver. 1.0.2.1 

17. 

 

WARRANTY INFORMATION 

ACTiSYS Corporation warrants the first end-user purchaser, for a period of 1 year from the date of purchase, 

that this wireless interface (The Product) will be free from defective workmanship and materials, and agrees 

that it will, at its option, either repair the defect or replace the defective Product or part thereof at no charge to 

the purchaser for parts or for labor. 
 

This warranty does not apply to any appearance items of the Product, any consumable items such as paper, 

ink ribbon, or batteries supplied with the Product, or to any equipment or any hardware, software, firmware, 

or peripheral other than the Product.  This warranty does not apply to any Product the exterior of which has 

been damaged or defected, which has been subjected to misuse, abnormal service or handling, or which has 

been altered or modified in design, construction or interfacing.  Tampering with Label Voids Warranty. 
 

In order to enforce the rights under this limited warranty, the purchaser should mail, ship or carry the Product, 

together with proof of purchase, to ACTiSYS. 
 

The limited warranty described above is in addition to whatever implied warranties may be granted to 

purchasers by law.  To the extent permitted by applicable law, ALL IMPLIED WARRANTIES INCLUDE THE 

WARRANTIES OF MERCHANT ABILITY AND FITNESS FOR USER ARE LIMITED TO A PERIOD OF 1 

YEAR FROM THE DATE OF PURCHASE.  Some states do not allow limitations on how long an implied 

warranty lasts, so the above limitation may not apply to you. 
 

Neither the sales personnel of the seller nor any other person is authorized to make any warranties other 

than those described above, nor to extend the duration of any warranties beyond the time period described 

above on behalf of ACTiSYS. Corporation. 
 

The warranties described above shall be the sole and exclusive remedy available to the purchaser.  

Correction of defects, in the manner and for the period of time described above, shall constitute full 

satisfaction of all claims, whether based on contract, negligence, strict liability or otherwise.  In no event shall 

ACTiSYS Corporation be liable or in any way responsible, for any damages or defects in the Product which 

were caused by repair or attempted repairs performed by anyone other than ACTiSYS technician.  Nor shall 

ACTiSYS Corporation be liable or in any way responsible for any incidental or consequential economic or 

property damage. Some states do not allow the exclusion of incidental or consequential damages, so the 

above exclusion may not apply to you. 

FOR YOU RECORDS 

For your assistance in reporting this product in case of loss or theft, please record below the model number 
and serial, which are located on the bottom of the case. Please retain this information.

 

Model Number:  

Serial Number: 

Date of Purchase: 

 

 

 

Содержание ACT-IR100UD-MDT

Страница 1: ...10 490 8024 Fax 1 510 623 7268 Web http www actisys com E mail irda info actisys com ACT IR100UD MDT USB to IrDA IrLPTTM Secondary Print Adapter User Manual September 3 2010 Ver 1 0 2 1 Copyright 2007...

Страница 2: ...NSTALLATION 10 7 COM PORT CHECK 11 8 UTILITIES UNINSTALLATION 12 9 DRIVER UNINSTALLATION 13 10 FILE RECEIVE UTILITY 15 10 1 Configuration 15 10 2 Start Recv 16 10 3 Stop Recv 16 10 4 Open to Print 16...

Страница 3: ...D MDT User Manual Copyright 2007 2010 ACTiSYS Corp Confidential Information 3 of 25 Sep 3 2010 Ver 1 0 2 1 15 CHARACTERISTICS AND SPECIFICATION 23 16 ACT IR100UD MDT DONGLE DIMENSIONS 23 17 WARRANTY I...

Страница 4: ...SYS generic LPT mode Include All in 1 driver installation and new setup package with File Receive Utility Config utility along with all in 1 driver 1 0 2 1 9 3 2010 Customized for MDT ACTiSYS reserves...

Страница 5: ...ich is due to the violation of ACT IR100UD MDT Do not expose the unit to moisture as this will damage the internal circuitry Do not expose the unit to extreme temperatures It should not be placed in d...

Страница 6: ...ps which is flexible setting by IrDA devices Provides a File Receive utility for the following features a Configurable options to select COM port Time out Baud rate DSR CTS Location to save the file E...

Страница 7: ...D MDT USB dongle is NOT plugged into PC until you have installed the driver z Note2 From Add or Remove Program in Control Panel of Win 98 ME 2K XP or from Programs and Features in Control Panel of Win...

Страница 8: ...ual Copyright 2007 2010 ACTiSYS Corp Confidential Information 8 of 25 Sep 3 2010 Ver 1 0 2 1 d A License Agreement window will show up as below Click Yes to continue e Then a Choose Destination Locati...

Страница 9: ...UD MDT User Manual Copyright 2007 2010 ACTiSYS Corp Confidential Information 9 of 25 Sep 3 2010 Ver 1 0 2 1 f You will be asked to Select Program Folder Click Next to continue g Click Finish to end th...

Страница 10: ...INSTALLATION a After completed the Utilities Installation setup will continue to install the Driver User can also select ACT IR100UD DriverInstaller_v1210 20100408 exe in CD to run manually b Then a...

Страница 11: ...right corner of Tool Bar and display the message Prolific USB to Serial Comm Port the first time you plug in 7 COM PORT CHECK To confirm if the installation is successful you can open Device Manager...

Страница 12: ...Confidential Information 12 of 25 Sep 3 2010 Ver 1 0 2 1 8 UTILITIES UNINSTALLATION a Open Add or Remove Programs from Control Panel select ACT IR100UD MDT Then click Change Remove as below b It will...

Страница 13: ...010 Ver 1 0 2 1 d It will then pop up a Warning window to remind you for uninstalling driver from Control Panel Click OK 9 DRIVER UNINSTALLATION 1 Open Add or Remove Programs on Control Panel 2 Select...

Страница 14: ...User Manual Copyright 2007 2010 ACTiSYS Corp Confidential Information 14 of 25 Sep 3 2010 Ver 1 0 2 1 3 It will ask you to confirm as below window Click Yes to continue 4 After seeing Uninstall Compl...

Страница 15: ...UTILITY 10 1 Configuration User can configure the following parameter as show in below figure i Select COM Port to which the dongle is connected Refer to Chapter 7 COM PORT CHECK ii Set Timeout perio...

Страница 16: ...lect the location where to store the received file NOTE Default file stored location is C Program Files ACTISYS ACT IR100UD MDT You can change to any other location you preferred vi Select the File Ex...

Страница 17: ...ters Then plug in this dongle to USB Check COM port as per Chapter 7 COM PORT CHECK Step 2 Open ACT IR100UD MDT File Receive Utility Go to Start Menu Programs ACTiSYS ACT IR100UD MDT click on ACT IR10...

Страница 18: ...ceived text data from opposite IrDA device ACT IR100UD MDT will automatically popup a received file to text editor like Notepad as shown below 3 sec after It will also generate a log file entry of the...

Страница 19: ...on 19 of 25 Sep 3 2010 Ver 1 0 2 1 12 COMSET COMMUNICATION PARAMETER SETTINGS 1 Plug in ACT IR100UD MDT dongle to USB port 2 Check the correct COM port number connected Refer to Chapter 7 COM PORT CHE...

Страница 20: ...filed select the correct Port number E g COM Port 14 Then you will see ACTiSYS IR100UD READY message as shown in below figure NOTE ACT IR100UD MDT dongle has been preset baud rate to 115 2 Kbps as its...

Страница 21: ...l NOTE This is a common Utility of COMSET Configuration for generic ACT IR100UD actually Although it opens window for Mode setting but ACT IR100UD MDT supports Secondary mode Only So DO NOT change it...

Страница 22: ...Tab Primary Protocol Settings This is for Primary Protocol Settings Again please DO Leave it to IrLPT since this is the Default of ACT IR100UD MDT Do NOT change it Save Configuration Note If you chang...

Страница 23: ...rned On LED blinks rapidly one time then off Secondary mode DSR activated LED stays off It is in stand by status Dongle is connected to another IrDA device LED blinks rapidly The blinking speed is bas...

Страница 24: ...by applicable law ALL IMPLIED WARRANTIES INCLUDE THE WARRANTIES OF MERCHANT ABILITY AND FITNESS FOR USER ARE LIMITED TO A PERIOD OF 1 YEAR FROM THE DATE OF PURCHASE Some states do not allow limitatio...

Страница 25: ...yright 2007 2010 ACTiSYS Corp 25 of 25 Sep 3 2010 Ver 1 0 2 1 18 CONTACT INFORMATION ACTiSYS Corporation 921 Corporate Way Fremont CA 94539 USA TEL 1 510 490 8024 FAX 1 510 623 7268 E Mail irda info a...

Отзывы: