background image

Page 12

© 2005 Active Research Limited

Active Research Limited

5, Wessex Trade Centre

Ringwood Road

Poole

Dorset

UK

BH12 3PF

Telephone: 

 

01202 746682  (International : +44 1202 746682)

Fax:    

 

01202 746683  (International : +44 1202 746683)

Actisense™

 on the Web: For advice, support and product details

E-mail:   

 

[email protected]

Website: 

 

www.actisense.com

Active Research

 on the Web: For specialist consultancy and customisation

E-mail:   

 

[email protected]

Website: 

 

www.activer.com

 

Company Information

Содержание NDC-3

Страница 1: ...er NDC 3 B User Manual Issue 1 31 Multiple talker interface for use with the NMEA 0183 standard Serial data networking of marine electronic devices instruments Personal computer RS232 interface to NME...

Страница 2: ......

Страница 3: ...mpatible RS 232 bi directional port 5 Technical features 5 Software updates 5 Connecting devices together 6 The basics 6 The NMEA signals 6 The different NMEA standards 6 Connections 7 Connecting to N...

Страница 4: ...n the NMEA sentence is validated Therefore the electronic device s supplying the NDC 3 with NMEA data retain s the sole responsibility for the NMEA data s validity Foreword Actisense recognises that i...

Страница 5: ...m drive capability The full differential output ensures better quality communications and lower noise emissions on unshielded twisted pair cabling Full speci cation RS232 interface ensures that any ma...

Страница 6: ...ine Tx or Out and used the ground as the other line similar to the way a computer serial port works This connection method is referred to as single ended instead of the differential method used by NME...

Страница 7: ...to a Personal Computer PC or other marine device capable of interfacing to a standard RS 232 port 4 Battery supply input Note 1 To complete the NMEA 0183 standard all device interconnection NMEA cable...

Страница 8: ...connection ID s Simply connect A to A and B to B refer to gure 2 NMEA Talker device 3 This device does not conform completely to the NMEA 0183 standard However by connecting to A and its G Ground to t...

Страница 9: ...ine and one for the RX line Use the spare wire in each pair as ground and connect the cable shield to ground only at the computer end 3 The TX of the NDC 3 should be connected to the RX of the compute...

Страница 10: ...ion Also indicates that no data is currently being received by the NDC 3 hardware Green Flashing 1 10 per second Normal and data Rx mode No error No response required A normal operation mode that indi...

Страница 11: ...e reduces to 2v 32 mA Output short circuit current 50 55 mA Baud rate xed see note 3 4 8 kbit sec Data propagation delay 1 0 100 ms RS 232 Input voltage range 15 15 V Input voltage threshold LOW 0 8 1...

Страница 12: ...202 746682 International 44 1202 746682 Fax 01202 746683 International 44 1202 746683 Actisense on the Web For advice support and product details E mail support actisense com Website www actisense com...

Отзывы: