Action pump 6008 Скачать руководство пользователя страница 1

General Safety Information

It is the
responsibility of

the user to operate the pump in
conformance with OSHA rules for
dispensing liquids. Pump containers
should be grounded when using with
flammable liquids to avoid static
electricity. Pump should be washed out
before usage since processing
lubricants could contaminate fluids.

1.When using a hand pump (especially

when pumping flammable,
combustible or hazardous liquids)
follow all electrical and safety codes,
as well as the United States
Occupational Safety and Health Act
(OSHA), most recent National

Electrical Code (NEC), National Fire
Protection, Inc. * (NFPA) Code 30
(Flammable and Combustible Code),
NFPA 56A (Standard for use of
Inhalation Anesthetics), NFPA 77
(Static Electricity), NFPA 78
(Lightning Protection Code), NFPA
80 (Standard for Fire Doors and
Windows), NFPA 251 (Standard
Method of fire Test of Building
Construction), NFPA 704
(Identification of the Fire Hazards of
Materials), other NFPA codes, local
codes and ordinances, as needed in
a particular application

2.Know the pump application,

limitations, and potential hazards.

The "WARNING" statements
indicate potential hazardous
conditions for the operator or
equipment. TAKE NECESSARY STEPS
TO PROTECT PERSONNEL AND
EQUIPMENT.

NOTE: 

Pump should only be used with

liquids compatible with pump
component materials. Consult PUMP
CHEMICAL COMPATIBILITY CHART and
PUMP SPECIFICATIONS. Also, the
chemical supplier should be consulted
regarding any questions of chemical
compatibility, proper and safe use and
handling of chemical. Misapplication of
pump or use of noncompatible liquids
will void warranty.

Action Barrel Pumps

Operating Instructions & Parts Manual   

6008 and 6009

Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described.
Protect yourself and others by observing all safety information. Failure to comply with instructions could result in personal injury and/or
property damage! Retain instructions for future reference.

Description

Action hand operated barrel pumps will deliver between eight ounces per stroke
and sixteen ounces per stroke depending on your specific model. The pumps are
designed to fit 

3

/

4

" and 2" threaded openings in 15, 30 and 55 gallon barrel and

drums. Both pumps are also designed to fit 2 

5

/

8

" flexspout openings for 5 gallon

pails. The extension tubes included reach the bottom of 55 gallon barrels. Model
6008 barrel pump is adjustable from 2, 4, 6 or 8 ounces per stroke. Model 6009 is
adjustable from 4, 8, 12 or 16 ounces per stroke. Both pumps have polypropylene
outer bodies and polyethylene inner parts. They are used for pumping water,
water-based liquids and detergents.

Specifications

Flow rate per stroke . . . . . . . . . . . . . . . . . . . . . . . . 8 ounces. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 ounces
Mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 gal. flex 2 

5

/

8

" . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 

5

/

8

" flex

Inlet. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

1

/

2

" . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

1

/

2

"

Outlet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

1

/

2

" . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

1

/

2

"

Bung Adapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2" Polypropylene (PP) . . . . . . . . . . . . . . . . . . . . . . . . . . . 2" (PP)
Suction Tube . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32" Polyethylene (PE) . . . . . . . . . . . . . . . . . . . . . . . . . . . 32" (PE)

(Length & Material)

Packing Gland . . . . . . . . . . . . . . . . . . . . . . . . . . . . . PE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . PE
Wetted Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . PE & PP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . PE & PP
SSU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SAE 40W Oil @ 70˚F (about 4,000 SSU) . . . . . . . . . . . . . SAE 40W Oil @ 70˚
Max. Temp.  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 140˚F . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 140˚F

WARNING

6008

6009

Содержание 6008

Страница 1: ... consulted regarding any questions of chemical compatibility proper and safe use and handling of chemical Misapplication of pump or use of noncompatible liquids will void warranty Action Barrel Pumps Operating Instructions Parts Manual 6008 and 6009 Please read and save these instructions Read carefully before attempting to assemble install operate or maintain the product described Protect yoursel...

Страница 2: ...ine Be sure extinguisher is in operating condition check the pressure gauge or indicator Be familiar with its proper use Consult local fire department for the correct type of extinguisher for your application Extinguishers rated ABC by the National Fire Protection Association are appropriate for most applications e Provide positive shut off valves on all permanent fuel supplies Fuel lines must be ...

Страница 3: ...ove cap on FLEXSPOUT closure and remove diaphragm Ref B Insert tube extension into side then snap over the other side 4 To remove pump with adapter from pail pull towards side of pail and snap off making sure to hold pail down Operation 1 The pump is now ready for operation Liquids should begin flowing on second or third upstroke If slight leakage should occur simply tighten packing nut Ref No 2 o...

Страница 4: ...lene 6008 18 6009 18 1 12 Cylinder body Polypropylene 6008 01 6009 01 1 13 Drum bung Polypropylene NA NA 1 14 Adapter Polypropylene 6008 258 6009 258 1 15 Discharge spout Polyethylene 6008 13 6009 13 1 16 Spout cap Polyethylene 6008 20 6009 20 1 17 Tube connector Polyethylene 6008 17 6009 17 1 18 Dip tube Polyethylene 6008 18 6009 18 1 19 Dip tube Polyethylene 6008 19 6009 19 1 20 Tube clamps Stee...

Отзывы: