ACTpro 20 Pin Entry Keypad
Pin Pad Cable Connections
Core
Colour
Description
1
White
Media Sense (open collector)
2
Green
Clock (open collector)
3
Blue
Data (open collector)
4
Red
5V Power (for reader only)
5
Black
0V Ground
6
Brown
Red LED control (negative applied)
7
Yellow
Green LED control (negative applied)
8
Orange
12V Power (for ACT20 only)
Shield
Bonded to Reader housing
ACTpro 20 Specification
Voltage
12VDC nominal (10.516V)
Current
20mA standby, 75mA maximum
Output Sink Current
50mA maximum
Operating Temperature
-10
o
C to +55
o
C
Cable
8-core screened (shared with reader)
Reader Distance
Max 30m from controller
Operation with ACTpro 1000 Controller
Note that the ACTpro 20 may only be used with clock and data
readers.
The ACTpro 20 is a rugged metal-housed pinpad for use with a separate controller. It is
usually used in conjunction with an ACTpro 1010 magnetic swipe card reader for pin
and swipe operation. Physically similar to the ACT 10, the function of this device is quite
different. The ACTpro 20 is a slave device which transmits each keypress directly to the
system controller. The unit is connected to the controller via an 8 core screened cable.
The same cable may be used to carry the signals from a swipe reader as the ACTpro 20
connects in parallel (refer to diagram).
PIN entry on the ACTpro 1000/2000 or ACTpro 100 is selected by setting the PIN
Required option in the Installer menu/Door settings/Timed actions menu for the doors
in question. A valid PIN must also be entered for the required group or user.
The unit acts as a slave to the ACTpro 1000/2000 controller and is connected in
parallel with the reader (swipe or proximity). Normally the unit is dormant with only the
standby LED illuminated. When a pin only entry is required the X button must be
pressed before the pin code is entered, the keypad backlight and all LEDs illuminate.
When a pin code is required with a swipe card the pin code is entered after the card is
swiped. The ACTpro 1000/2000 will process the entered PIN/Card and illuminate the
red or green LED to indicate access granted or denied.