ACT ACTPRO 1010 Скачать руководство пользователя страница 1

ACTpro 1010 

Reader (Exit)

Wire both readers in parallel but leave 
the SENSE line on  the Exit reader unconnected.

Controller

SENSE
CLOCK
DATA
+5v
0v
RED
GREEN

Car
d/Pr

ox Reader

White
Green
Blue
Red
Black
Brown
Yellow
Orange

SENSE
CLOCK
DATA
+5V
0V
RED
GREEN
Not Connected

Wiring for Clock and Data 

The +5V reader supply on ACT controllers is normally rated 
at 100mA. Typically this is sufficient to power 2 ACT readers. 
Note however that readers from other manufacturers may need 
to be powered separately if their current requirements exceed 
this or if they require 12V.

The standard wiring colours for
ACTpro 1010 reader is shown above. 
Readers should be a maximum of 30m
from the controller when powered 
from +5V and a maximum of 100m
when powered from +12V.

Unit C1, South City Business Centre, Tallaght, Dublin 24, Ireland. 
Telephone: 353 1 466 2570.  Telefax: 353 1 452 0427. E-mail: [email protected]  Web: www.accesscontrol.ie

ACTpro 1010 Wiring for Entry / Exit

ACTpro 1010 
Reader (Entry)

The ACTpro 1010 is configured to read ISO Track 2 of magnetic stripe card media.

Reader Specification

Voltage:   

 

 

  

5-12V DC

Current:   

 

 

  

15 mA standby, 20 mA maximum

Operating Temperature:  

-10 degrees C to +55 degrees C

Media:   

 

 

 

ISO standard high or low coercivity magnetic card 

Speed:   

 

 

 

12.7-172 cm/s

Head Life  

 

 

 

>1,000,000 passes

Cable:   

 

 

 

3m x 8-core screened

Reader Distance:   

 

Max 30m from controller powered with 5V DC

 

 

 

 

 

  

Max 100m from controller powered with 12V DC

  

 

18-0004 Issue 4