ELECTRICAL WIRING CONNECTION
•
All wires must be firmly connected.
•
All wires must not touch the water piping, or any
moving parts of the fan motor.
•
The connecting wires between the indoor unit and the
outdoor unit must be clamped on the wire clamps
as shown in the figure.
•
The power supply cord must be equivalent to H05RN-F
(245IEC57) which is the minimum requirement.
Cooling unit
IMPORTANT :
The figures shown in the table are for information purpose only. They should be checked and selected
to comply with the local/national codes of regulations. This is also subject to the type of installa-
tion and conductors used.
Wire Clamp
Interconnection
cable
Power Supply
Cable
WM 10 FW ~ 25 FW
Model
07 / 10 / 15
20 / 25
Voltage range
220V – 240V
1Ph / 50Hz +
Power supply cable size
mm
2
1.5
2.5
Number of wire
3
3
Interconnection Cable size
mm
2
1.5
2.5
Number of wire
3
3
Recommended Fuse
A
15
20