S76G/S78G Commands Set Reference
v1.6.5
July 2, 2018
14 of 73
Product Name
Version
Doc No
Date
Page
>> sleep 100 sec uart_on (
See this message, it means it starts to sleep.)
adsfajkl (
Any UART input can wake it up.)
>> Ok
(Wake up after 20 seconds)
sip sleep 20 uart_off
>> sleep 20 sec uart_off
>> Ok
(Not allow to use the value which is not the multiple of 10.)
sip sleep 22 uart_off
>> Invalid
3.1.8
sip set_baudrate <baudrate> <password>
<baudrate> A decimal string representing UART1 baudrate, it can be assigned as 4 kinds of rate,
9600
,
19200
,
57600
and
115200
.
<password> A decimal string representing password that provides baudrate protection. This
baudrate setting command can only be delivered when password is correct. And the assigned
baudrate setting would be stored in EEPROM and would not be changed by sip factory_reset
command.
Response:
Ok
, if <Status> string is valid.
Invalid
, if <Status> string is not valid
Purpose: Change UART1 baudrate immediately.
Example:
sip set_baudrate 9600 24399520
>> Ok
3.1.9
(production verification) sip get_hw_model_ver
Response: A string representing hardware model & firmware version.
Purpose: Get hardware model name and firmware version by only using this command.
Example:
sip get_hw_model_ver