Chapter 4 Installation
WARNING
CARBON MONOXIDE POISONING HAZARD
Failure to properly vent this furnace or other appliances could result in death, personal injury and / or property
damage.
If this furnace is replacing a previously common-vented furnace, it may be necessary to resize the existing
vent system to prevent oversizing problems for the other remaining appliance( s ). See Venting the Furnace
section of this instruction.
AVERTISSEMENT
DANGER D’EMPOISONNEMENT AU MONOXYDE DE CARBONE
Un défaut de ventilation pour cette chaudière ou d’autres appareils peut causer la mort, des dommages
corporels et / ou des dégâts matériels.
Si cette chaudière remplace une chaudière précédente à ventilation partagée, il pourra être nécessaire de
redimensionner le système de ventilation existant pour éviter des problèmes de surdimensionnement au niveau
du ou des autres appareils. Reportez-vous à la section Ventilation de la chaudière dans ce manuel d’instructions.
4.1 Location and Clearances
Choose the location or evaluate the existing location based upon the minimum clearance and furnace
dimensions.
MODEL
Min.
Clearance
From the
Front
Min. Clearance
Around Both
Sides
Min. Clearance
Above the Unit
Min. Clearance
Below the Unit
Min. Clearance
Around the Flue
Vent or Pipe
GAA1024 / 1030 / 1036
36”
19”
2”
0”
18”
GAA1042 / 1048/1060
36”
19”
2”
0”
18”
Table 1. Minimum Clearances from Unprotected Combustible Material and For Service
WARNING
CARBON MONOXIDE POISONING HAZARD
Failure to follow safety warnings could result in serious injury, death, or property damage.
Do NOT operate furnace in a corrosive atmosphere containing chlorine, flourine or any other damaging
chemicals which could harm the furnace and vent system, and permit spillage of combustion products into
an occupied space.
Refer to Venting the Furnace section, contaminated combustion air for combustion air evaluation and remedy.