MiniPuck Model ST132-06x0 Two-Wire TC/mV Transmitter
_________________________________________________________________________________
______________________________________________________________________________________
Acromag, Inc. Tel: 248-295-0880 Email:
24
Model Number:
ST13/Input-Isolation/Power/Approvals/SIL-Calibration
ST13 is the model Series. The prefix “ST” denotes the “Smart Transmitter”
family. The trailing “2” digit denotes an TC input type. The “0” after the
hyphen denotes non-
isolated, the “6” that follows denotes 2-wire loop
powered. The “0” or “1” following denotes CE Approvals Only, or CE and
UL/cUL Class 1, Division 2 Approvals. The last “0” digit refers to No SIL
Approvals.
Note that ST132 models can be ordered with or without the factory
configuration option. Factory configuration requires selection of input type
(
J, K, T, R, S, E, B, N, or
100mV
), filter control (Low, Med, or High), CJC
Control (On, Off), I/O Scaling, and Sensor Fault Detection (Upscale or
Downscale).
Default factory calibration settings are for Thermocouple Type J, upscale
break, high filter and a -40°F to 176°F (-40°C to 80°C) input span to drive a
4mA to 20mA output span. This calibration allows the product to be used as
an Ambient Temperature Sensing amplifier. By jumpering the input plus to
the input minus terminal, the unit may be used within panels and enclosures
to transmit continuous ambient temperature data via the 4-20mA output.
Recalibration of any model will require use of an ST13C-SIP configuration
kit ordered separately (see Accessories).
Models can be mounted in DIN Form B connection heads using the ST130-
MTG mounting kit, or on DIN rail using the ST130-DIN kit. These kits are
purchased separately (see Accessories)
Input:
T/C or ±100mV Peak
Analog Inputs millivolt or thermocouple input channels per model. The Input
of this unit can be configured to accept one of several input ranges below.
The unit must be wired and configured for the intended input type and range
(see Connections section for details). The following paragraphs summarize
this model’s input types, ranges, and applicable specifications.
Thermocouple (See Table 1)
: Configurable for J, K, T, R, S, E, B, and N
thermocouple types as shown in Table 1. Linearization, Cold-Junction
Compensation (CJC), and lead break detection are included.
Table 1: Supported TC Types, Ranges, and Accuracy
TC
C Temp Range
Typical
1,2
(of Full-Scale
Span)
Typical
(of Narrow Span)
J
-210 to +760
C
±0.1%
±0.5°C (Spans <= 500°C)
K
-200 to +1372
C
±0.1%
±0.5°C (Spans <= 500°C)
T
-260 to +400
C
±0.1%
±0.5°C (Spans <= 500°C)
R
- 50 to +1768
C
±0.1%
±1.0°C (Spans <= 1000°C)
S
- 50 to +1768
C
±0.1%
±1.0°C (Spans <= 1000°C)
E
-200 to +1000
C
±0.1%
±0.5°C (Spans <= 500°C)
B
+260 to 1820
C
±0.1%
±1.0°C (Spans <= 1000°C)
N
-230 to -170
C;
-170 to +1300
C
±0.1%
±0.1%
±1.0°C (Spans <= 500°C)
±0.5°C (Spans <= 500°C)
SPECIFICATIONS
Model Numbers
Model ST132-0600
Signal Transmitter
TC Input
Non-Isolated
Two-Wire Loop-Powered
CE Approved Only
NO SIL Approvals
Analog Inputs