microBlox® Signal Splitter
Model uBSP-P-1
Acromag, Inc. Tel: 248-295-0880
- 5 -
http://www.acromag.com
- 5 -
https://www.acromag.com
Key Features
•
Field-pluggable microBlox® input module allows you to change an input type
on this carrier in the field. Modules are over-molded and RoHS compliant,
and offer superior shock, moisture, and dust protection.
•
Software Configuration via wired USB to a Windows based personal computer
or tablet running Windows software, or wired USB OTG (On-The-Go) to an
Android smartphone or tablet using our Agility Configuration App. Software
for USB Configuration and the Agility app is free (no other software required).
•
Separate isolated voltage and current outputs at each splitter output channel
support ±10V, ±5V, 0-10V, 0-5V, or 0-20mA and 4-20mA ranges. A third
isolated AUX/host voltage output is sourced from the microBlox® module.
•
Input range and output ranges are adjustable, input and outputs can be
scaled independently and the input may even be scaled differently for each
output.
•
Normal or Reverse Acting splitter outputs.
•
Variable Digital Input Filter adjustment.
•
Designed and manufactured for High Quality/High Reliability with AS9100
(Aerospace Quality)/ISO9001.
•
Designed, hardened, and thoroughly tested for use in Harsh Environments.
•
CE Approved & UL / cUL Class I, Division 2 Approvals.
•
FCC Conformity Class B.
•
ATEX / IECEx Certified for Explosive Atmospheres.
II 3 G Ex nA IIC T3 Gc -40
o
C
≤
Ta
≤
+75
o
C
DEMKO 18 ATEX 2086X IECEx UL 18.0092X
•
Carrier includes a voltage or current output at each output channel.
•
Better than ±0.1% output accuracy.
•
Wide ambient temperature operation from -40°C to +75°C.
•
All I/O and power ports are transient protected.
•
Wide-range isolated DC power input from 6-32V.
•
LED indicators for module Bluetooth wireless technology link, module power,
and splitter output fault detection aides trouble-shooting.
•
High 1500VAC safety Isolation between field input, each output, and power.
Individually isolated for common-mode voltage up to 250VAC, or 354V DC off
DC power ground, on a continuous basis (will withstand 1500VAC
HIPOT/dielectric strength test for one minute without breakdown). Complies
with test requirements of ANSI/ISA-82.01-1988 for voltage rating specified.
•
Shock (25G) and Vibration Immunity (4G) - Conforms to: IEC 60068-2-6: 10-
500 Hz, 5G, 2 Hours/axis, for sinusoidal vibration; IEC 60068-2-64: 10-500 Hz,
5G-rms, 2 Hours/axis, for random vibration, and IEC 60068-2-27: 30G, 11ms
half-sine, 18 shocks at 6 orientations and 50G, 3ms half-sine, 18 shocks at 6
orientations, for mechanical shock.
•
EMC (Electromagnetic Compatibility)
–
Min Immunity per BS EN 61000-6-1
(2007); CE marked, per EMC Directive 2014/30/EU. Electrostatic Discharge
Immunity (ESD), per IEC 61000-4-2; Radiated Field Immunity (RFI), per IEC
61000-4-3 and ETSI EN 301 489; Electrical Fast Transient Immunity (EFT), per
IEC 61000-4-4; Surge Immunity, per IEC 61000-4-5. Conducted RF Immunity
(CRFI), per IEC 61000-4-6.
•
Emissions - This is a Class B Product with Emissions per BS EN 61000-6-3
(2007+A1:2011) and Spurious Emissions per ETSI EN 300 328. Enclosure Port,
per CISPR 16. Low Voltage AC Mains Port, per CISPR 16.
•
Installation Category - Suitable for installation in a Pollution Degree 2
environment with an Installation Category (Over-voltage Category) II rating
per IEC 1010-1 (1990).