Quick Overview 

 Android Reconfiguration...continued 

 

Input/Output Configuration 

 
The I/O Configuration screen is shown at left and is used to Configure your 
splitter Input, splitter Outputs, and AUX output.  Scroll down this screen to 
set your input type/range, input digital filtering level, rescale each output, 
enable and scale the AUX output, and even scale the input differently for 
each output via this screen. 
 
Note that if your unit is connected when you select this tab, the app 
aut

omatically reads your splitter’s current I/O and scaling information and 

displays it. 
 
Likewise, changing any option on this page sends the changes to the 
splitter immediately. 
 
 
 
 
 
 
Note that the Device Status is indicated at the bottom of all pages and will 
report if changes were sent successfully (Connected). 

 

 

 

Input Calibration 

If you have correctly setup your unit and encounter excessive error, you 
may click the Calibration tab to display the Calibration control screen 
shown at left, which presents Input calibration controls first, followed by 
Output calibration controls as you scroll down the page. 

 

IMPORTANT:

  The splitter has had its input & output channels factory 

calibrated with high precision.  Attempting to recalibrate the input or 
outputs may degrade performance if done improperly, or using low grade 
equipment.  Consider recalibration carefully. 

 
The selected input range is indicated at the top and this is the range that 
will be calibrated.  The software does not use your scaled range zero to 
calibrate, but the zero of the nominal input range selected.  Some sub-
ranges have their calibration extrapolated from the calibration of a larger 
native range.  Always calibrate the largest native range first to keep its 
recalibration from over-writing any sub-range calibration.   

 
For input zero calibration, connect a precise input signal level for the zero 
of your range, then tap the 

[CALIBRATE INPUT ZERO]

 button one time to 

set the input ADC level to its input range zero (0%) point. 

 
For full-scale calibration, connect a precise input signal level for the full-
scale value of your range, then tap 

[CALIBRATE INPUT FULL-SCALE] 

one 

time to set the input ADC level to its input range full-scale (100%).   

 
The device status at the bottom of the page will report if the calibration 
was sent successfully.

 

 

 

Содержание microBlox uBSP-P-1

Страница 1: ...uB Field Input Modules USER S MANUAL ACROMAG INCORPORATED Tel 248 295 0880 30765 South Wixom Road Fax 248 624 9234 Wixom MI 48393 2417 U S A email sales acromag com Copyright 2018 Acromag Inc Printed...

Страница 2: ...ections Each Splitter Output Supports Voltage or Current 11 AUX Voltage Output Connections 12 CONFIGURATION SOFTWARE 12 CONFIGURATION SOFTWARE 13 Quick Overview Android Reconfiguration 13 Quick Overvi...

Страница 3: ...or human life is involved It is important that you perform satisfactory overall system design and it is agreed between you and Acromag that this is your responsibility The information of this manual...

Страница 4: ...lox module carrier adds wide input isolated power cold junction compensation for thermocouple modules dual isolated current and or voltage outputs an AUX voltage output plus LED indication for module...

Страница 5: ...than 0 1 output accuracy Wide ambient temperature operation from 40 C to 75 C All I O and power ports are transient protected Wide range isolated DC power input from 6 32V LED indicators for module B...

Страница 6: ...a Windows based personal computer laptop or a wired USB OTG connection to an Android smartphone tablet This carrier provides isolated host power to the module a host USB port a host voltage output th...

Страница 7: ...nd lift it from the rail To attach the carrier to T type DIN rail position the top groove of the DIN Clip along the rail and push the bottom inward to snap it into place on the DIN rail To remove it f...

Страница 8: ...te 16 26 AWG 1 31 0 13mm2 solid or stranded wire with a minimum temperature rating of 85o C Input wiring may be shielded or unshielded type twisted pair or shielded twisted pair input wiring is recomm...

Страница 9: ...function as a simple single channel I O carrier for Bluetooth wireless technology modules and you may configure a B module on this carrier to drive its single AUX output using Bluetooth wireless techn...

Страница 10: ...ual 8501 043 uB34 2 3 Wire uB35 4 Wire RTD Input User s Manual 8501 044 Introduction to Agility Configuration Tool for microBlox 8501 047 uB37 uB47 TC Input User Manual 8501 050 uB04 uB08 uB16 Back Pa...

Страница 11: ...ected in their connection diagrams for the specific plug in module model Ground connections noted are recommended for best results and help protect the unit and its isolated circuits by giving each is...

Страница 12: ...ers laptops or a USB OTG connection to Android smartphones tablets with the Agility APP The Windows USB software for your model operates like the Agility APP software Below is a brief introduction to...

Страница 13: ...he device indicated to the right of Selected Device and move to the main portion of the app shown in the second screen at left Note Android requires user permission to access external hardware If the...

Страница 14: ...nostic exchange and review the results returned If one or more tests indicate Failed you can also tap the down arrow message below the self test report to access additional information regarding faile...

Страница 15: ...akin to a power on reset of the splitter You can tap RESET FACTORY CALIBRATION to get out of trouble if you ever miscalibrate a splitter this only affects splitter calibration You can tap RESTORE FAC...

Страница 16: ...ents Input calibration controls first followed by Output calibration controls as you scroll down the page IMPORTANT The splitter has had its input output channels factory calibrated with high precisio...

Страница 17: ...our output range For Full Scale calibration use the output adjustment slider and the coarse and fine adjustment controls to precisely set your output full scale level while precisely monitoring your o...

Страница 18: ...The input type of the plug in module is shown at the top of the screen actual input value not the scaled input value is polled Select the Indicator pointer to set your desired indication to Digital v...

Страница 19: ...nication Set up I O Config Test and Calibration A short description of each of these pages follows This section is used to select a connected transmitter and open close communications with it Device c...

Страница 20: ...ich output of this splitter you are calibrating Input First set the Input Range to calibrate in the I O Config Test page and be sure to click the Send I O Config button before attempting calibration O...

Страница 21: ...us feature of the uBSP P 1 splitter and its USB software is that it allows all versions of microBlox input modules to be reconfigured using a wired USB connection both B and fixed range uB models exce...

Страница 22: ...range zero full scale endpoints I O scaling in a channel can be done in reverse to produce a reverse acting output signal Refer to the block diagram to gain a better understanding of how this splitter...

Страница 23: ...fect on standard microBlox modules Unit Fails to Start up or Initialize Check power voltage level and capacity making sure that it is at least 6V and of sufficient capacity select a current capacity 2...

Страница 24: ...Check CJC Setting Refer to your module specifications and determine the required CJC status for your model Enable or disable CJC as required for your module by setting the channel CJC DIP switch acco...

Страница 25: ...his isolator and cable are also included in TT SIP see above USB A B Cable USB A B Cable Order 4001 112 This is a 1 meter USB A B replacement cable for connection between your PC and the USB isolator...

Страница 26: ...fer to your plug in module instructions for wiring Accuracy Better than 0 05 of span typical relative to the installed module plus an additional 0 05 of span relative to its operation on this carrier...

Страница 27: ...12 20mA 20mA 59577 5 0V 10 0V 62556 5 0V 10V 65535 5 5V 11 0V 5 5V 11V 24mA 24mA RES 1 59577 1 59577 1 59577 1 59577 1 54612 1 43689 1 lsb 83 925uV 167 8uV 167 8uV 335 7uV 0 34132uA 0 34132uA Span 0 0...

Страница 28: ...sourced from module Channel BLE Blue Channel Blue ON indicates Linking to channel is enabled for uBxx B Bluetooth wireless technology enabled models via the BLE DIP switch of the channel This LED is...

Страница 29: ...o an Android smartphone tablet The USB interface is used to configure and calibrate the input of the module plugged into this carrier and each output of this splitter Because the input module power an...

Страница 30: ...equivalent 1 59W Typical MAX TOTAL w uB42 or equivalent 1 96W Typical 1 Note Incremental power consumption of current output is 0 02W mA POWER REQUIRED BY FEATURE BY MODULE TYP MODEL BASE V OUT I OUT...

Страница 31: ...ses Operating Temperature 40 C to 75 C 40 F to 158 F Storage Temperature 40 C to 85 C 40 F to 185 F Relative Humidity 5 to 95 non condensing Isolation Input field isolation is provided by the plug in...

Страница 32: ...than pollution degree 2 as defined in EN IEC 60664 1 2 The equipment shall be installed in an enclosure that provides a degree of protection not less than IP 54 and only accessible with the use of a t...

Отзывы: