to 250VAC, or 354V DC off DC power ground, on a 
continuous basis (will withstand 1500VAC dielectric strength 
test for one minute without breakdown).  This complies with 
test requirements outlined in ANSI/ISA-82.01-1988 for the 
voltage rating specified.  

Installation Category:

  Suitable for installation in a Pollution 

Degree 2 environment with installation category (over-voltage 
category) II rating. 

Radiated Field Immunity (RFI):

  Complies with IEC1000-4-3 

Level 3 (10V/M, 80 to 1000MHz & 900MHz keyed) and 
European Norm EN50082-1. 

Electromagnetic Interference Immunity (EMI):

  No relay trips 

will occur beyond 

0.25% of input span from setpoint, and no 

output shifts will occur beyond 

0.25% of span, under the 

influence of EMI from switching solenoids, commutator 
motors, and drill motors. 

Electrical Fast Transient Immunity (EFT):

  Complies with 

IEC1000-4-4 Level 3 (2KV power; 1KV signal lines) and 
European Norm EN50082-1. 

Electrostatic Discharge (ESD) Immunity:  

Complies with 

IEC1000-4-2 Level 3 (8KV/4KV air/direct discharge) to the 
enclosure port and European Norm EN50082-1. 

Surge Immunity:  

Complies with IEC1000-4-5 Level 3 (2.0KV) 

and European Norm EN50082-1. 

Radiated Emissions:  

Meets or exceeds European Norm 

EN50081-1 for class B equipment.

 

 
FIELD CONFIGURATION AND CONTROLS 

 
Field program of transmitter zero and full-scale (all models), plus 
alarm setpoint and dropout levels (811T-1500 only), is 
accomplished with module push-buttons and LED indicators.  
This is useful for making adjustments in the absence of a host 
computer.  

Note:

 The unit must first be configured using the 

Configuration Software before its configuration can be modified in 
the field. 

 
Module Push Buttons (See Dwg 4501-642 for Location): 

Mode - 

Used to change mode of field configuration.

 

Set - 

Used to accept input data during field calibration. 

Up - 

Used to increment output level during field calibration.  

Used to reset a latched alarm relay in operating mode. 

Down - 

Used to decrement output level during field 

calibration.  Used to reset a latched alarm relay in operating 
mode. 

LED Indicators (See Dwg 4501-642 for Location): 

Operating (Run) Mode 
Run (Green) -

 Constant ON indicates power is applied and 

unit is operating normally.  Upon power up, the module may 
take up to 20 seconds to perform internal diagnostics, during 
diagnostics, the relay may cycle states before the module 
becomes operational. Flashing ON/OFF indicates that unit is 
performing diagnostics (first second following power-up), or 
has failed diagnostics (after a few seconds). 

Status (Yellow) -

 The ST LED will flash ON/OFF when an 

over/under range limit of the A/D converter is reached. 

Zero/Full-Scale (Yellow) -

 Turned OFF in Run mode. 

Relay (Yellow) - 

Constant ON indicates alarm condition for 

relay.  During field configuration, this LED has a different 
function (see below). 

 
 
Field Configuration Mode

 

Run (Green) -

 Turned OFF in this mode. 

Status (Yellow) - 

Blinks each time the “SET” button is 

pressed to capture an I/O signal in this mode. 

Zero/Full-Scale (Yellow) - 

ON or FLASHING if zero or full-

scale is being adjusted in this mode (See Table 4). 

Relay (Yellow) - 

ON or FLASHING if alarm setpoint or 

dropout is being adjusted in this mode (See Table 4). 

 
 
HOST COMPUTER COMMUNICATION 
 

Host Communication Port (SPI):

 IntelliPack SPI port (standard 

RJ11 6-wire phone jack).  See Drawing 4501-643 for location. 
Configuration information is downloaded from the host 
computer through one of its EIA232 serial ports.  This port 
must be connected to the module through an Acromag 
IntelliPack Serial Port Adapter.  This Serial Port Adapter 
serves as an isolated interface converter between EIA232 
and the IntelliPack’s SPI port. 

Baud Rate (EIA232):

  19.2K baud. 

 
 

SOFTWARE CONFIGURATION 

 

Units are fully reprogrammable via our user-friendly Windows 95

 

or NT

 IntelliPack Configuration Program (Model 5030-881).  A 

cable (5030-902) and converter (5030-913) are required to 
complete the interface (Software Interface Package 800C-SIP).  
See Drawing 4501-643.  The following transmitter and alarm 
attributes are selectable via the IntelliPack Configuration 
Software.  Refer to the IntelliPack Transmitter Configuration 
Manual (8500-570) for a more detailed explanation of these 
attributes and their application.   
 

Input Configuration

 

Input - Range:  

The transmitter can be configured to accept any 

one of the fourteen input range types described in the Input 
Specifications using the IntelliPack Configuration Software.  
Units are engineering units appropriate to the input range 
selected (V DC, mA DC, A AC, % ). 

Input - Samples/Averaging:

  Indicates the number of input 

signal A/D conversions to be used to compute an average 
value.  Samples can be set to 1 (default), 2, 4, 8, or 16.  This 
is useful to help filter out transients.  Note the response time 
will be increased by the factor selected.   

Input Calibration:

  The IntelliPack Configuration Software is 

used to calibrate the input range of this module. 

 
Output Configuration 
Output - Range: 

 Analog output can be configured for one of five 

ranges of current or voltage.  For voltage output, a jumper 
must also be installed between the output “I+” and “JMP” 
terminals (remove this jumper for current output). 

Voltage (Jumper Required):

  0 to 10V DC, 0 to 5V DC. 

Current:

 0 to 20mA DC, 4 to 20mA DC, or 0 to 1mA DC. 

Output - Mode:

  Select a Normal Acting (ascending), or Reverse 

Acting (descending) output response. 

Output Calibration

:  The configuration software can be used to 

calibrate the output conditioning circuit of this module.

 

 

Transmitter Configuration 
Transmitter - Scaling:

  Scaling is performed after averaging and 

converts the engineering units of the input range (or a portion 
of the input range) to 0 to 100% at the output.  That is, 
scaling allows virtually any part of the selected input range to 

Содержание IntelliPack 811T Series

Страница 1: ...rms Process Current Voltage Input USER S MANUAL ACROMAG INCORPORATED 30765 South Wixom Road Wixom MI 48393 2417 U S A Tel 248 295 0880 Fax 248 624 9234 Copyright 1997 Acromag Inc Printed in the USA Da...

Страница 2: ...factory overall system design It is agreed between the Buyer and Acromag that this is the Buyer s responsibility 1 0 INTRODUCTION These instructions cover hardware functionality of the transmitter mod...

Страница 3: ...applications Custom IntelliPack module configurations are also possible please consult the factory Key IntelliPack 811T Features Agency Approvals cULus Listed Easy Windows Configuration Fully reconfig...

Страница 4: ...transparent to the user It receives its power from the IntelliPack module The adapter has a DB9S connector that mates to the common DB9P serial port connector of a host computer The adapter also has a...

Страница 5: ...r NT Configuration Program and Serial Port Adapter Configuration is normally done prior to field installation since field configurability via the module s push buttons is generally limited to zero ful...

Страница 6: ...wing the instrument s deadband and may produce contact chatter The long term effect of this will reduce the life of mechanical relays To reduce this undesired effect you should increase the effective...

Страница 7: ...rease the amount of increment or decrement 10 Press the SET push button to accept the full scale value Note that every time the SET button is pressed the yellow Status LED will flash once and the full...

Страница 8: ...ks and calibrates the performance of each module Please refer to Acromag s Service Policy Bulletin or contact Acromag for complete details on how to obtain service parts and repair PRELIMINARY SERVICE...

Страница 9: ...itation current of process current inputs Input Filter Normal mode filtering plus digital filtering optimized and fixed per input range within the ADC Noise Rejection Normal Mode 40dB 60Hz typical wit...

Страница 10: ...rail mountable for flexible high density approximately 1 wide per unit mounting See Enclosure Dimensions Drawing 4501 642 for details Dimensions Width 1 05 inches Height 4 68 inches Depth 4 35 inches...

Страница 11: ...Relay Yellow Constant ON indicates alarm condition for relay During field configuration this LED has a different function see below Field Configuration Mode Run Green Turned OFF in this mode Status Ye...

Страница 12: ...the effect of reducing narrowing the instrument s deadband and may produce contact chatter Another long term effect of contact chatter is a reduction in the life of the mechanical relay contacts To re...

Страница 13: ...L TIPL EXER AND CONDITIONING INPUT SIGNAL 1 6 BIT A D SHL D SHIEL D ISOL ATION RTN INPUT I 2 3 2 4 2 5 V 2 2 MODEL 811T 1500 UNIT ONLY REL AY REL AY ISOL ATION 4 5 COM N O RELAY 4 6 SHL D NC 4 3 4 4 N...

Страница 14: ...ation S oftware or Module P ush B uttons LIMIT A LA RM Transfer Functions Linear P roportional S quare Root Linearizer ON OFF A larm On Off K 1 A nalog OUTP UT type ALARM OUTPUT BLOCK A larm Configura...

Страница 15: ...IntelliPack Series 811T Transmitter Alarm User s Manual DC Voltage Current Input __________________________________________________________________________________________ 15...

Страница 16: ...TB2 2 2 V 2 3 I 2 4 RTN I NPUT SHLD 2 5 2 6 EARTH G RO UND TB2 M O D E M O DE SW I TCH Z F S ZERO FUL L SCAL E L ED YEL L O W Acr om ag R U N RUN PW R L ED G REEN STATUS L ED YEL L O W R L Y S T REL...

Страница 17: ...GROUND L OOP TO GROUND AS THIS WOUL D PRODUCE INPUTS GROUND ONL Y ONE INPUT DO NOT CONNECT THE SECOND INPUT P A S S I NG T H ROUGH C E N T E R H OLE S E E I NP U T RA NGE S E LE C T I ON T A B LE A C...

Страница 18: ...TACT 42 34 SPDT CONTACTS PROTECTION AC RELAY POWER DIODE DC RELAY POWER PROTECTION FIGURE A CONTACT SPDT CONTACTS INPUT CONNECTIONS TB1 OUTPUT JUMPER I TO JMP FOR VOLTAGE OUT POWER 8XXT 1500 RELAY OUT...

Страница 19: ...____________________________________ 19 RUN Acromag RLY S T Z FS 118 9 4 68 95 3 3 75 MODE S E T D IN EN 50022 35mm T R AIL D IN MOU N TIN G C L 2 34 59 4 SC R EWD R IVER SLOT FOR R EMOVAL FR OM T R A...

Страница 20: ...__________________________________________ 20 Revision History The following table details the revision history for this document Release Date Version EGR DOC Description of Revision 03 AUG 2017 K CAP...

Страница 21: ...IntelliPack Series 811T Transmitter Alarm User s Manual DC Voltage Current Input __________________________________________________________________________________________ 21 Notes...

Отзывы: