Table 7: Analog Output Range Resolution & Accuracy 

 
Output Range 

 
Resolution 

Accuracy

1,2  

Percent-of-Span 

 

 

Output 

Overall 

0 to 20mA DC 

0.0025% 

0.025% 

0.075% 

4 to 20mA DC 

0.0025% 

0.025% 

0.075% 

0 to 1mA DC 

0.0370% 

0.100% 

0.150% 

0 to 10V DC 

0.0025% 

0.025% 

0.075% 

0 to 5V DC 

0.0030% 

0.050% 

0.100% 

 

Notes (Table 7): 

1.    Voltage outputs unloaded.  Loading will add “I*R” error. 
2.    Software calibration produces high accuracy. 
3.    All output current and voltage ranges are subsets of the 

0-20mA range. 

 
General Output Specifications 

Digital-to-Analog Converter:

  Analog Devices AD420AR-32, 

16-bit 

-

.  Monotonic to 16 bits. 

Integral Non-Linearity:

 

0.002% (

1.4LSB) of span typical, 

0.012% (

7.9LSB) of span maximum, for ranges utilizing 

full output span (0-24mA, 0-10V DC). 

Output Temperature Drift:

  Better than 

20ppm/

C Typical, 

50ppm/

C Maximum. 

Output Settling Time:

  3ms to 0.1% of full-scale. 

 
RELAY OUTPUT SPECIFICATIONS 

 
Model 811T-1500 units include a SPDT electro-mechanical alarm 
relay which provides one independent Single Pole Double Throw 
(SPDT), Form C, electromagnetic, dry-contact sealed relay.  The 
relay operates as a limit alarm with control of deadband/ 
hysteresis, latching/non-latching contacts, failsafe/non-failsafe 
modes, plus relay time delay.  

Note:

  In order to control a higher amperage device, such as a 

pump, an interposing relay may be used (see Drawing 4501-646). 

 
SPDT Alarm Relay Specifications (811T-1500 Units Only): 

Electrical Life - CSA Ratings:

 

25VDC, 5A, 10

5

 operations, resistive. 

48VDC, 0.8A, 10

5

 operations, resistive. 

240VDC, 0.1A, 10

5

 operations, resistive. 

120VAC, 5A, 3x10

4

 operations, resistive. 

240VAC, 5A, 3x10

4

 operations, resistive. 

Contact Material:

  Silver-cadmium oxide (AgCdO). 

Initial Dielectric Strength:

  Between open contacts: 

1000VAC rms. 

Expected Mechanical Life:

  20 million operations.  External 

relay contact protection is required for use with inductive 
loads (see Contact Protection Drawing 4501-646). 

Relay Response (No Relay Time Delay):

  Relay contacts 

will switch within 150ms typical, for an input step change from 
10% of span on one side of an alarm point to 5% of span on 
the other side of the alarm point. 

 

ENCLOSURE/PHYSICAL SPECIFICATIONS 

 

Unit is packaged in a general purpose plastic enclosure that is 
DIN rail mountable for flexible, high density (approximately 1” 
wide per unit) mounting.  See Enclosure Dimensions Drawing 
4501-642 for details. 
 

Dimensions

:  Width = 1.05 inches, Height = 4.68 inches, Depth 

= 4.35 inches (see Drawing 4501-642). 

DIN Rail Mounting (-xx0x):

  

DIN rail mount, Type EN50022; “T” 

rail (35mm). 

Connectors:

  Removable plug-in type terminal blocks; 

Current/Voltage Ratings: 15A/300V;  Wire Range: AWG #14-
24 (stranded or solid copper);  separate terminal blocks are 
provided for power/output, input, and relay contacts.  For 
supply connections, use No. 14 AWG copper wires rated for 
at least 75

C. 

Case Material:

  Self-extinguishing NYLON type 6.6 polyamide 

thermoplastic, UL94 V-2, color beige; general purpose NEMA 
Type 1 enclosure. 

Printed Circuit Boards:

  Military grade FR-4 epoxy glass. 

Shipping Weight: 

1 pound (0.45 Kg) packed. 

 
APPROVALS (-xxx0) 

 
0

:     Agency Approvals - cULus Listed, UL File E199702 

 

Product approval is limited to general safety requirements of 

the above standards. 

 
Warning:

  This product is not approved for hazardous location  

                  applications. 
 

ENVIRONMENTAL SPECIFICATIONS 

 
Operating Temperature:  

-25

C to +70

C (-13

F to +158

F). 

Storage Temperature:  

-40

C to +85

C (-40

F to +185

F). 

Relative Humidity:

  5 to 95%, non-condensing. 

Power Requirements:

  +10V Minimum to +36V DC Maximum.  

Current draw is a function of supply voltage (see Table 8).  
Current shown in Table 8 assumes that the input excitation 
supply is delivering 20mA, the output circuit is at 20mA, and 
the IntelliPack Serial Interface Adapter is connected.  An 
internal diode provides reverse polarity protection.  

 

CAUTION:

  Do not exceed 36VDC peak, to avoid 

                   damage to the module.

 

 
Table 8:  811T Supply Current 

Supply 

Voltage 

Supply Current 

(Relay Energized) 

Supply Current 

(Relay De-energized) 

10V 

275mA 

240mA 

12V 

220mA 

195mA 

15V 

170mA 

150mA 

24V 

110mA 

100mA 

36V 

80mA 

75mA 

Note:

  Disconnecting the Serial Port Adapter will reduce 

current consumption 8% on average.  Unloading the input 
excitation supply will reduce current consumption about 22%. 
 

IMPORTANT 

– External Fuse:

  If unit is powered from a supply 

capable of delivering more than 1A to the unit, it is recommended 
that this current be limited via a high surge tolerant fuse rated for 
a maximum current of 1A or less  
(for example, see Bel Fuse MJS1). 
 

Power Supply Effect:   

DC Volts:  

Less than 

0.001% of output span change per 

volt DC for rated power supply variations. 

60/120 Hz Ripple:

  Less than 0.01% of output span per volt 

peak-to-peak of power supply ripple. 

Isolation:  

Input, output, power, and optional relay output circuits 

are isolated from each other for common-mode voltages up 

Содержание IntelliPack 811T Series

Страница 1: ...rms Process Current Voltage Input USER S MANUAL ACROMAG INCORPORATED 30765 South Wixom Road Wixom MI 48393 2417 U S A Tel 248 295 0880 Fax 248 624 9234 Copyright 1997 Acromag Inc Printed in the USA Da...

Страница 2: ...factory overall system design It is agreed between the Buyer and Acromag that this is the Buyer s responsibility 1 0 INTRODUCTION These instructions cover hardware functionality of the transmitter mod...

Страница 3: ...applications Custom IntelliPack module configurations are also possible please consult the factory Key IntelliPack 811T Features Agency Approvals cULus Listed Easy Windows Configuration Fully reconfig...

Страница 4: ...transparent to the user It receives its power from the IntelliPack module The adapter has a DB9S connector that mates to the common DB9P serial port connector of a host computer The adapter also has a...

Страница 5: ...r NT Configuration Program and Serial Port Adapter Configuration is normally done prior to field installation since field configurability via the module s push buttons is generally limited to zero ful...

Страница 6: ...wing the instrument s deadband and may produce contact chatter The long term effect of this will reduce the life of mechanical relays To reduce this undesired effect you should increase the effective...

Страница 7: ...rease the amount of increment or decrement 10 Press the SET push button to accept the full scale value Note that every time the SET button is pressed the yellow Status LED will flash once and the full...

Страница 8: ...ks and calibrates the performance of each module Please refer to Acromag s Service Policy Bulletin or contact Acromag for complete details on how to obtain service parts and repair PRELIMINARY SERVICE...

Страница 9: ...itation current of process current inputs Input Filter Normal mode filtering plus digital filtering optimized and fixed per input range within the ADC Noise Rejection Normal Mode 40dB 60Hz typical wit...

Страница 10: ...rail mountable for flexible high density approximately 1 wide per unit mounting See Enclosure Dimensions Drawing 4501 642 for details Dimensions Width 1 05 inches Height 4 68 inches Depth 4 35 inches...

Страница 11: ...Relay Yellow Constant ON indicates alarm condition for relay During field configuration this LED has a different function see below Field Configuration Mode Run Green Turned OFF in this mode Status Ye...

Страница 12: ...the effect of reducing narrowing the instrument s deadband and may produce contact chatter Another long term effect of contact chatter is a reduction in the life of the mechanical relay contacts To re...

Страница 13: ...L TIPL EXER AND CONDITIONING INPUT SIGNAL 1 6 BIT A D SHL D SHIEL D ISOL ATION RTN INPUT I 2 3 2 4 2 5 V 2 2 MODEL 811T 1500 UNIT ONLY REL AY REL AY ISOL ATION 4 5 COM N O RELAY 4 6 SHL D NC 4 3 4 4 N...

Страница 14: ...ation S oftware or Module P ush B uttons LIMIT A LA RM Transfer Functions Linear P roportional S quare Root Linearizer ON OFF A larm On Off K 1 A nalog OUTP UT type ALARM OUTPUT BLOCK A larm Configura...

Страница 15: ...IntelliPack Series 811T Transmitter Alarm User s Manual DC Voltage Current Input __________________________________________________________________________________________ 15...

Страница 16: ...TB2 2 2 V 2 3 I 2 4 RTN I NPUT SHLD 2 5 2 6 EARTH G RO UND TB2 M O D E M O DE SW I TCH Z F S ZERO FUL L SCAL E L ED YEL L O W Acr om ag R U N RUN PW R L ED G REEN STATUS L ED YEL L O W R L Y S T REL...

Страница 17: ...GROUND L OOP TO GROUND AS THIS WOUL D PRODUCE INPUTS GROUND ONL Y ONE INPUT DO NOT CONNECT THE SECOND INPUT P A S S I NG T H ROUGH C E N T E R H OLE S E E I NP U T RA NGE S E LE C T I ON T A B LE A C...

Страница 18: ...TACT 42 34 SPDT CONTACTS PROTECTION AC RELAY POWER DIODE DC RELAY POWER PROTECTION FIGURE A CONTACT SPDT CONTACTS INPUT CONNECTIONS TB1 OUTPUT JUMPER I TO JMP FOR VOLTAGE OUT POWER 8XXT 1500 RELAY OUT...

Страница 19: ...____________________________________ 19 RUN Acromag RLY S T Z FS 118 9 4 68 95 3 3 75 MODE S E T D IN EN 50022 35mm T R AIL D IN MOU N TIN G C L 2 34 59 4 SC R EWD R IVER SLOT FOR R EMOVAL FR OM T R A...

Страница 20: ...__________________________________________ 20 Revision History The following table details the revision history for this document Release Date Version EGR DOC Description of Revision 03 AUG 2017 K CAP...

Страница 21: ...IntelliPack Series 811T Transmitter Alarm User s Manual DC Voltage Current Input __________________________________________________________________________________________ 21 Notes...

Отзывы: