Acromag DT236-0600 Скачать руководство пользователя страница 36

Model DT23x-0600

 

 

Dual Two-Wire DC I/V Input Transmitters 

 

 

 

 

 

Acromag, Inc. Tel: 248-295-0880  

            - 36 -                                   

http://www.acromag.com  

- 36 - 

https://www.acromag.com 

 

Output

…continued

 

 
CAUTION:

  Do not exceed 36VDC 

peak to avoid damage to the unit.  
Terminal voltage at/above 7V 
minimum must be maintained 
across the output during 
operation.

  

 

 
 
 
 
Compute R

load

 (Max) = 

(V

supply

 - 7V)/0.021A for 21mA 

output current.  Refer to the 
table at right.

 

Output Power Supply: 

 Loop powered from 7-32V DC SELV (Safety Extra Low 

Voltage), 24mA maximum.  The voltage across the output must never exceed 36V, 
even with a shorted load.  Set this level to provide a minimum of 21mA over-range 
current to the load (0.021*R typical), plus 7V across the output terminals, plus any 
interim line drop.  Reverse polarity protection is inherent as output terminals are not 
polarized (± output labels of enclosure are for reference only). 

Output Power Supply Effect: 

 Less than 

0.001% of output span effect per volt DC of 

supply change within rated limits for load. 

Output Load Resistance Effect:

  Less than 

0.001% of output span effect for a 

100

 

change in load resistance. 

Output Compliance and Load Resistance Equation:

  7V minimum is required for each 

transmitter channel.  A channel will drive up to 17V to a load with a 24V loop supply 
and 20mA of loop current (800

Ω), assuming negligible line drop.  

 

 

V

supply 

Volts 

Max R

load

 w/21mA and No IR Line Drop 

7V 

0Ω

 

10V 

143

 

12V 

238

 

18V 

524

 

24V 

81

0Ω

 

32V 

119

0Ω

 

 

USB Interface

 

 

 
 
 
 
 
 
 
 

Unit includes a USB socket for temporary connection to a PC or laptop for set up and 
reconfiguration (or optionally to a USB-OTG cable connected to an Android 
smartphone or tablet).  USB isolation is required when connected to a grounded 
input sensor or driver (see note below).  During reconfiguration and calibration, the 
transmitter receives power from both the USB port and the output loop.  Both power 
sources must be present to calibrate the unit. 

 

CAUTION: 

Do not attempt to connect USB in a hazardous environment.  Transmitter 

should be set up and configured in a safe environment only. 

 

Data Rate:

  USB v1.1 full-speed only, at 12Mbps.  Up to 32K commands per second.  

USB 2.0 compatible. 

Transient Protection:  

Adds transient voltage protection on USB power & data lines. 

Inrush Current Limiting:  

Includes series inrush current limiting at USB power. 

Cable Length/Connection Distance

:  5.0meters maximum. 

 

 

 

!

Содержание DT236-0600

Страница 1: ...oltage Inputs Model DT237 0600 DC 1V 10V Medium Voltage Inputs Model DT238 0600 DC 15V 150V High Voltage Battery Sources Inputs USER S MANUAL ACROMAG INCORPORATED Tel 248 295 0880 30765 South Wixom Ro...

Страница 2: ...NECTIONS 7 Input Connections 7 Output Power Connections 9 Earth Ground Connections 12 USB Connections 13 CONFIGURATION SOFTWARE 14 Quick Overview Android Reconfiguration 14 Quick Overview Windows 15 O...

Страница 3: ...it is agreed between you and Acromag that this is your responsibility The information of this manual may change without notice Acromag makes no warranty of any kind with regard to this material inclu...

Страница 4: ...and calibrated w Windows software via USB or a wired USB OTG connection to Android smartphones or tablets Dual Channels in a thin 17 5mm wide enclosure for high density mounting Operates as a dual tr...

Страница 5: ...s an isolated 4 20mA output current loop linearly with input current or voltage The transmitter output signals are two wire 4 20mA current loops allowing the unit to transmit over long distances with...

Страница 6: ...it upward to lift it from the rail while prying the spring clip back with a screwdriver To attach the module to T type DIN rail angle the top of the unit towards the rail and place the top groove of t...

Страница 7: ...sion 2 or ATEX IECEx Zone 2 it should utilize two end stops see Acromag 1027 222 to help secure modules to the DIN rail not shown Input Connections Note This transmitter may operate as a single channe...

Страница 8: ...Model DT23x 0600 Dual Two Wire DC I V Input Transmitters Acromag Inc Tel 248 295 0880 8 http www acromag com 8 https www acromag com...

Страница 9: ...designations are for reference only with current normally input to Output and returned via Output current sinking Output loop 1 powers input 1 the microcontroller Loop supply voltages should be from...

Страница 10: ...o either the unit or local to the remote receiver of the output loop Common receiver devices may include the input channel of a Programmable Logic Controller PLC a Distributed Control System DCS or a...

Страница 11: ...ipple Most modern systems will use high speed acquisition at the load making them more sensitive to noise pickup high frequency noise may be significantly reduced for these applications by placing a 0...

Страница 12: ...re connection to that metal housing s ground terminal green screw is usually required using suitable wire per applicable codes As a rule of good practice isolated circuits are normally earth grounded...

Страница 13: ...icles in the air USB Signal Isolation is Required See Below You may use Acromag model USB ISOLATOR to isolate your USB port or you can optionally use another USB signal isolator that supports USB Full...

Страница 14: ...iew a connection drawing note that no connection is required to just view drawings Android devices normally require user permission to access external hardware If No Device Permission is indicated in...

Страница 15: ...Setup First Select Connect to Unit Here The initial Communication Setup screen for the DT236 model is shown at left after clicking Open to open communication with a connected module Select from conne...

Страница 16: ...guration page as required before calibrating the input and be sure to click the Send I O Config button of the Configuration page Click Input Cal Instructions to begin input calibration Next when you c...

Страница 17: ...ck your input readings see screen at left Use this screen to verify communication with the unit or diagnose problems with your input wiring Click Start Polling to periodically read both input channels...

Страница 18: ...e output current accurately at each output to calibrate the unit You could connect a current meter in series in each output loop to read the loop current directly not recommended Alternatively you cou...

Страница 19: ...he selected unit s Model Serial Number Manufacturer and connection Status will be displayed as shown in the third screen at left After you connect USB and Open communication with a unit the Status fie...

Страница 20: ...paths that differ by the nominal range supported For the DT236 the first input path A is at TB1 1 TB3 1 leftmost terminal of TB1 TB3 and intended for DC current only The second input path B is at TB1...

Страница 21: ...average noise but with slower I O response times Set the Scaled I O Sub Range Zero Full Scale Endpoints You may rescale a selected input and or output range differently for each channel and use a smal...

Страница 22: ...O Config Test page Additionally make sure you write your selections to the unit by clicking the Send I O Config button of that page Click the Input Cal Instructions button to begin input calibration...

Страница 23: ...channel Next use the course and fine adjustment buttons to adjust the output signal to precisely 20 000mA Be sure to measure this level accurately or performance will be degraded After driving the ou...

Страница 24: ...to periodically read the input channels and display their values in the fields below the polling button Note the simulated lamp next to the polling button flashes slowly each time it samples the input...

Страница 25: ...ed fly back converter operating in parallel with output loop 1 Setup involves selecting the operating mode input types ranges Current or Voltage filter levels and scaling input output range endpoints...

Страница 26: ...USB connected and config software running Close the current connection with the software then select and re open the transmitter for communication or simply exit the Configuration software and reboot...

Страница 27: ...Rload If transmit distance is especially long then it must have added voltage to support the IR drop in the wire Ideally the voltage should also have ample overhead to drive the load at the maximum up...

Страница 28: ...configure it and calibrate it Boot the configuration software to regain operation The USB port is intended for set up and configuration of the module and a unit should not be left connected to USB wi...

Страница 29: ...am the transmitter USB Isolator USB Isolator Order USB ISOLATOR USB Signal Isolator USB A B Cable 4001 112 Instructions 8500 900 This kit contains a USB isolator and a 1M USB A B cable for connection...

Страница 30: ...phone or tablet that support USB It is required to use the Acromag Agility Config Tool App for Android OS reconfiguration of this transmitter Note that the Acromag Agility Config Tool software APP is...

Страница 31: ...nputs for current and or voltage depending on the model Unit has separate input channels at TB1 and TB3 and each channel has two signal paths that support different ranges On DT236 DC current is input...

Страница 32: ...input range and filter selection within the ADC See also Normal Mode Noise Rejection and Output Response Time Noise Rejection Common Mode Varies by model with filter selection between no filtering and...

Страница 33: ...The effective I O resolution will be the lowest of the A D its normalized value or the output DAC Output DAC resolution is 1 part in 43690 for 4 20mA output Table 1 DT INPUT RESOLUTION PER INPUT PATH...

Страница 34: ...djustment When used with a D2336 module it also facilitates AC current input isolation from the ADC voltage input as well as redundant input isolation with respect to each output of this transmitter W...

Страница 35: ...capacitor is recommended at the load High frequency noise may be reduced or eliminated by placing a 0 1uF or 0 01uF capacitor directly across the load this can also raise RF immunity Output Ambient Te...

Страница 36: ...0 change in load resistance Output Compliance and Load Resistance Equation 7V minimum is required for each transmitter channel A channel will drive up to 17V to a load with a 24V loop supply and 20mA...

Страница 37: ...reason USB isolation is strongly recommended when connecting to a PC Otherwise in the absence of USB isolation and when connected to a grounded input 1 sensor a battery powered laptop could be used t...

Страница 38: ...tegory Suitable for installation in a Pollution Degree 2 environment with an Installation Category Over voltage Category II rating per IEC 1010 1 1990 Shock Vibration Immunity Random vibration Designe...

Страница 39: ...ours MTBF Years Failure Rate FIT1 25 C 1 177 353 hrs 134 4 years 849 4 40 C 783 595 hrs 89 5 years 1276 2 1 Note FIT is Failures in 109 hours Configuration Controls Refer to Operation Step By Step in...