Model DT23x-0600
Dual Two-Wire DC I/V Input Transmitters
Acromag, Inc. Tel: 248-295-0880
- 4 -
http://www.acromag.com
- 4 -
https://www.acromag.com
GETTING STARTED
DESCRIPTION
Symbols on equipment:
Means “Refer to User’s Manual
(this manual) for additional
information”
Model DT23x-0600 Dual Transmitters provide two isolated ANSI/ISA Type II
transmitters with isolated 2-wire current outputs. Units may operate as a dual
channel two-wire transmitter, a single channel 1 transmitter, or as a channel 1
signal splitter. These models interface with DC Current or DC voltage input signals
according to their model, isolate each input, and separately modulate two isolated
2-wire current loops linearly proportional to their respective inputs.
The DT236-0600 is designed for DC Current (0-20mA/4-20mA) and Low Voltage DC
signals (±0.5V/0-500mV). The DT237-0600 is designed for medium voltage DC
signals (±1V, ±5V, ±10V), and the DT238-0600 for large Voltage DC signals (±15V,
±75V, ±150V Battery Sources). Units provide an adjustable input range, input
isolation, variable input filtering, I/O scaling, and programmable output limits. All
units are setup and calibrated using a wired USB connection to a Windows-based PC
running configuration software (Windows 7 and later), or an Android-based tablet
or smartphone running our Agility mobile APP.
Key Features
•
Digitally configured and calibrated w/ Windows software via USB, or a wired
USB-OTG connection to Android smartphones or tablets.
•
Dual Channels in a thin 17.5mm wide enclosure for high-density mounting.
•
Operates as a dual transmitter, a single CH1 transmitter, or a CH1 splitter.
•
High measurement accuracy and linearity with 16-bit I/O conversion.
•
Adjustable input ranges and output ranges. Transmitter inputs and outputs
can be scaled independently and differently for each channel.
•
Variable input filter adjustment (none, low, medium, or high).
•
Each transmitter channel supports two input paths according to range model.
DT236 channels have separate input paths for 0-20mA/4-20mA/0-
11.17mA/±1mA, and ±0.5V/0-500mV. DT237 has separate input paths for
ranges up to ±1V and ±10V. DT238 has separate input paths s for high-level
ranges up to ±15V and ±150V Battery Sources.
•
Non-polarized 2-wire loop-powered output channels.
•
Output channels can transmit Normal or Reverse Acting output signals.
•
Extra output connection screw supports optional sourced output wire
termination (see optional Output/Power Connections).
•
Up or down-scale lead-break/burnout detection.
•
Transmitters have very low loop burden with terminal voltage down to 7V.
•
You may program your own output clamp limits or select Namur compliant
range/limits, helpful to discern over-range conditions from fault detection.
•
Wide ambient temperature operation from -40°C to +80°C.
•
Thoroughly tested and hardened for harsh environments.
•
CE Approved.
•
FCC Conformity Class B
•
cULus Listed - Class I/Division 2 - Haz. Loc., ATEX, & IECEx.
!