Содержание APCe8675

Страница 1: ...rutilized and idle equipment along with credit for buybacks and trade ins Custom engineering so your equipment works exactly as you specify Critical and expedited services Leasing Rentals Demos In sto...

Страница 2: ...XMC Carrier USER S MANUAL ACROMAG INCORPORATED 30765 South Wixom Road Wixom MI 48393 2417 U S A Tel 248 295 0310 Fax 248 624 9234 Copyright 2013 Acromag Inc Printed in the USA Data and specifications...

Страница 3: ...DING CONSIDERATIONS 16 3 SERVICE AND REPAIR 17 SERVICE AND REPAIR ASSISTANCE 17 PRELIMINARY SERVICE PROCEDURE 17 WHERE TO GET HELP 17 4 SPECIFICATIONS 18 PHYSICAL 18 Physical Configuration 18 Connecto...

Страница 4: ...ate or keep current the information contained in this manual No part of this manual may be copied or reproduced in any form without the prior written consent of Acromag Inc IMPORTANT SAFETY CONSIDERAT...

Страница 5: ...the fan can be easily removed With the fan removed the APCe8675 will fit in the space of a single slot High Speed Serial Rear I O The APCe8675 provides the capability to connect to neighboring carrier...

Страница 6: ...er board See Table 2 11 Acromag also offers a cable that makes the XMC rear I O signals routed through J14 and J1 accessible from the back panel of the PC This cable connects J1 to a MD68 connector mo...

Страница 7: ...should only be handled at a static safe workstation CARD CAGE CONSIDERATIONS Refer to the specifications for loading and power requirements Be sure that the system power supplies are able to accommoda...

Страница 8: ...x 6 FPGAs Table 2 2 JP2 Programming Reference Voltage Select Jumper VRef Voltage Jumper Position 3 3V 1 2 2 5V 2 3 CONNECTORS Refer Figure 2 Connectors on the APCe8675 carrier consist of two carrier I...

Страница 9: ...42 RIO8_P 9 RIO8_N 43 RIO9_P 10 RIO9_N 44 RIO10_P 11 RIO10_N 45 GND 12 GND 46 RIO11_P 13 RIO11_N 47 RIO12_P 14 RIO12_N 48 RIO13_P 15 RIO13_N 49 RIO14_P 16 RIO14_N 50 RIO15_P 17 RIO15_N 51 RIO16_P 18...

Страница 10: ...RIO5_N 12 RIO6_P 13 RIO7_P 14 RIO6_N 15 RIO7_N 16 RIO8_P 17 RIO9_P 18 RIO8_N 19 RIO9_N 20 RIO10_P 21 RIO11_P 22 RIO10_N 23 RIO11_N 24 RIO12_P 25 RIO13_P 26 RIO12_N 27 RIO13_N 28 RIO14_P 29 RIO15_P 30...

Страница 11: ...4 GND D14 DP14_P A15 DP15_P D15 GND A16 GND D16 DP16_P A17 DP17_P D17 GND A18 GND D18 DP18_P A19 DP19_P D19 DP00_N B1 DP01_N E1 GND B2 GND E2 DP02_N B3 DP03_N E3 GND B4 GND E4 DP04_N B5 DP05_N E5 GND...

Страница 12: ...LK_N C18 SIO1_N F18 SIO0_GCLK _P C19 SIO1_P F19 Table 2 7 P2 Board to Board Cable Connection to J16 User Signals Pin Description Number Pin Description Number DP00_P 1 DP10_P 2 DP00_N 3 DP10_N 4 DP01_...

Страница 13: ...SIO10_N 23 SIO11_N 24 SIO12_P 25 SIO13_P 26 SIO12_N 27 SIO13_N 28 SIO14_P 29 SIO15_P 30 SIO14_N 31 SIO15_N 32 SIO16_P 33 SIO18_GCLK_P 34 SIO16_N 35 SIO18_GCLK_N 36 SIO17_P 37 NC1 38 SIO17_N 39 NC1 40...

Страница 14: ...0_GCLK_N 23 SIO1_N 24 SIO2_P 25 SIO3_P 26 SIO2_N 27 SIO3_N 28 SIO4_P 29 SIO5_P 30 SIO4_N 31 SIO5_N 32 SIO6_P 33 SIO7_P 34 SIO6_N 35 SIO7_N 36 SIO8_P 37 SIO9_P 38 SIO8_N 39 SIO9_N 40 GND 41 GND 41 DP10...

Страница 15: ...3 SIO11_N 24 SIO12_P 25 SIO13_P 26 SIO12_N 27 SIO13_N 28 SIO14_P 29 SIO15_P 30 SIO14_N 31 SIO15_N 32 SIO16_P 33 SIO18_GCLK_P 34 SIO16_N 35 SIO18_GCLK_N 36 SIO17_P 37 NC1 38 SIO17_N 39 NC1 40 GND 41 GN...

Страница 16: ...lder side Connector gold finger numbers increase with distance from the bracket end of the printed circuit board Refer to the PCI Express bus specification for additional information on the PCI Expres...

Страница 17: ...CONSIDERATIONS Carrier boards are designed with passive filters on each supply line to each XMC module This provides maximum filtering and signal decoupling between the XMC modules and the carrier bo...

Страница 18: ...verify that it is correctly configured Replacement of the carrier and or IP with one that is known to work correctly is a good technique to isolate a faulty board CAUTION POWER MUST BE TURNED OFF BEF...

Страница 19: ...d XMC module This specification lists currents for the carrier board only The carrier board provides 3 3V 12V and 12V power to the XMC module 12V power can be supplied either from the PCIe bus 12V sup...

Страница 20: ...y per EN 61000 6 2 Electrostatic Discharge Immunity IEC6100 4 2 Radiated Field Immunity IEC61000 4 4 Electric Fast Transient Immunity IEC61000 4 4 Surge Immunity IEC 61000 4 5 Conducted R F Immunity I...

Страница 21: ...se Date Version EGR DOC Description of Revision 23 AUG 13 A JCL Initial Acromag release 6 SEP 13 B JCL Added Certificate of Volatility 12 DEC 13 C JCL ARP Removed P O Box from address on cover page As...

Страница 22: ...uipment Have surplus equipment taking up shelf space We ll give it a new home Learn more Visit us at artisantg com for more info on price quotes drivers technical specifications manuals and documentat...

Отзывы: