AcroPack Series AP560
CAN Bus Interface Module
- 49 -
Error Register
The ERR register indicates CAN bus status and protocol errors. It is read only.
All bits default to 0 at power up and maintain their status following reset. Bits
4:0 are reset following a host read.
Table 24 ERR (Read only, 0xDC)
BIT
FUNCTION
0
STUFERR
–
Stuff Error.
A bit stuffing error was detected in a received frame.
1
ACKERR
–
Acknowledgement Error.
An ACK error was detected in a receive frame.
2
CRC Error
–
CRC Error.
A CRC error was detected in a receive frame
3
FRMERR
–
Form Error.
A Form error was detected in a receive frame
4
BITERR
–
Bit Error.
A bit error was detected in a transmitted frame (the bit
observed on the bus was opposite to what was expected).
5
RXERRP
–
Receive Error Passive status indicator.
This bit is set when 128
≤ REC ≤ 255.
6
TXERRP
–
Transmit Error Passive status indicator.
This bit is set when 128 ≤ TEC ≤ 255.
7
BUSOFF
–
Buss-off indicator.
This bit is set when TEC > 255. Node is in bus off condition.
The bit is reset by HI-3111 when a successful bus recovery
sequence is detected (128 x 11 consecutive recessive bits).
The FILHIT3:0 bits will reflect this value.