AcroPack Series AP560
CAN Bus Interface Module
- 15 -
Table 2 Logic Interface Connections
Pin #
Name
Pin #
Name
51
+5V
2
52
+3.3V
3
49
+12V
2
50
GND
47
-12V
2
48
N.C. (+1.5V)
1
45
Present
4
46
N.C. (LED_WPAN#)
1
43
GND
44
N.C. (LED_WLAN#)
1
41
+3.3V
3
42
N.C. (LED_WWAN#)
1
39
+3.3V
3
40
GND
37
GND
38
N.C. (USB_D+)
1
35
GND
36
N.C. (USB_D-)
1
33
PETp0
34
GND
31
PETn0
32
SMB_DATA
5
29
GND
30
SMB_CLK
5
27
GND
28
N.C. (+1.5V)
1
25
PERp0
26
GND
23
PERn0
24
+3.3V
3
21
GND
22
PERST#
19
TDI (UIM_C4)
1
20
N.C. (W_DISABLE#)
1
17
TDO (UIM_C8)
1
18
GND
15
GND
16
N.C. (UIM_VPP)
1
13
RECLK+
14
N.C. (UIM_RESET)
1
11
REFCLK-
12
N.C (UIM_CLK)
1
9
GND
10
N.C. (UIM_DATA)
1
7
CLKREQ#
1
8
N.C. (UIM_PWR)
1
5
TCK (COEX2)
1
6
N.C. (+1.5V)
1
3
TMS
(COEX1)
1
4
GND
1
N.C. (WAKE#)
1
2
+3.3V
3
Note 1: Signals are not applicable for the AP560 implementation. Pins are
either “no connects” on the module or are repurposed for JTAG.
Note 2: +5V, +12V, and -12V power supplies have been assigned to pins that
are reserved in the mini-PCIe specification.
Note 3: All +3.3Vaux power pins are changed to +3.3V power.
Note 4: The ‘Present’ signal is tied to circuit common on the AP module.
Note 5: The SM Bus signals SMB_CLK and SMB_DATA are used to clock a
carrier location serial stream from the carrier. These signals are under the
control of the AcroPack module.
2.
PROGRAMMING INFORMATION
This Section provides the specific information necessary to program and
operate the AP560 module.
Содержание AcroPack AP560
Страница 28: ...AcroPack Series AP560 CAN Bus Interface Module 28 Figure 2 Standard Data Frame...
Страница 30: ...AcroPack Series AP560 CAN Bus Interface Module 30 Figure 3 Extended Data Frame...
Страница 32: ...AcroPack Series AP560 CAN Bus Interface Module 32 Figure 4 Remote Frame...
Страница 34: ...AcroPack Series AP560 CAN Bus Interface Module 34 Figure 5 Error Frame...