AP513 ACROPACK
USER
’S MANUAL
Acromag, Inc. Tel: 248-295-0310
- 51 -
http://www.acromag.com
- 51 -
www.acromag.com
5.3.2 Other Environmental Requirements
5.3.2.1 Relative Humidity
The range of acceptable relative humidity is 5% to 95% non-condensing.
5.3.2.2 Isolation
The RS-232 ports are individually isolated from digital circuitry and from each
other. They maintain 250V(AC rms or DC) of isolation from digital and
100V(AC rms or DC) isolation from each other.
Note
: Not all AcroPack carriers are able to maintain this level of isolation.
Consult the AcroPack carrier documentation for supported isolation
voltages.
5.3.3 Vibration and Shock Standards
The AcroPack module is designed to pass the following Vibration and Shock
standards.
Vibration, Sinusoidal Operating:
Designed to comply with IEC 60068-2-6:
10-500Hz, 5G, 2 Hours/axis
Vibration, Random Operating:
Designed to comply with IEC 60068-2-64: 10-
500Hz, 5G-rms, 2 Hours/axis
Shock, Operating:
Designed to comply with IEC 60068-2-27: 30G, 11ms half
sine, 50G, 3mS half sine, 18 shocks at 6 orientations for both test levels
5.3.4 EMC Directives
The AcroPack module complies with EMC Directive 2004/108/EC.
•
Immunity per EN 61000-6-2:
Electrostatic Discharge Immunity (ESD), per IEC 61000-4-2.
Radiated Field Immunity (RFI), per IEC 61000-4-3.
Electrical Fast Transient Immunity (EFT), per IEC 61000-4-4.
Surge Immunity, per IEC 61000-4-5.
Conducted RF Immunity (CRFI), per IEC 61000-4-6.
•
Emissions per EN 61000-6-4:
Enclosure Port, per CISPR 16.
Low Voltage AC Mains Port, per CISPR 16.
Note:
This is a Class A product
5.4 Reliability Prediction
Table 5.4 MTBF
MTBF (Mean Time Between Failure):
MTBF in hours using MIL-HDBK-217F,
FN2.
Per MIL-HDBK-217, Ground Benign, Controlled, G
B
G
C
Temperature
MTBF (Hours)
MTBF (Years)
Failure Rate (FIT
1
)
25°C
6,957,683
794.3
143.7
40°C
4,548,928
519.3
219.8