Acromag ACPS3310 Скачать руководство пользователя страница 21

AcroPack Series ACPS3310 

CompactPCI-Serial Carrier Board 

- 21 - 

CAUTION:  POWER MUST BE TURNED OFF BEFORE REMOVING OR INSERTING BOARDS 

WHERE TO GET HELP 

If you continue to have problems, your next step should be to visit the 
Acromag website at 

https://www.acromag.com

Our website contains the 

most up-to-date product and software information. 

Go to the “Support” tab or your specific AcroPack model ordering page.

 

Acromag’s application engineers can also be contacted directly 

for technical 

assistance via email, telephone, or FAX through the contact information listed 
below.  Note that an email question can also be submitted from within the 

Knowledge Base or directly from the “Contact Us” tab.  When needed, 

complete repair services are also available. 

Phone: 248-295-0310 
Email

[email protected]

 

5.

 

SPECIFICATIONS 

PHYSICAL 

Physical Configuration   

Length (ACPS3310) ........................ 6.299 inches (160.00 mm) 
Height ............................................. 3.937 inches (100.00 mm) 
Board thickness .............................. 0.063 inches (1.60 mm) 
Max component height ................. 0.402 inches (10.21 mm) 
Max component height under AcroPack modules 

0.0789 inches (2.00 mm) 

Weight............................................ 5.57 oz. (158 g) 

Connectors 

P1 (CPCI-S) ..................................... 72-pin header, AIRMAX (Amphenol 10052825-101LF) 
J3 (Carrier Field I/O) ....................... 68-pin, Stacked, Champ (TE Connectivity 5787962) 
P7, 8 (AcroPack Field I/O) .............. 100-pin socket (Samtec SS5-50-3.00-L-D-K-TR) 
J1, 2 (Mini-PCIe) ............................. 52-pin socket (TE Connectivity 1759457-1) 
P9 (JTAG) ........................................ 14-pin header (Molex 87832-1420) 

Isolation 

This AcroPack carrier is designed to provide isolation between the AcroPack Field I/O signals and the host.  
The AcroPack module must also be an isolated AcroPack module to maintain the isolation between the logic 
and field I/O signals.  Unless isolation is provided on the AcroPack module itself, the field I/O connections are 
not isolated from the PCIe bus. 
 
Host logic and field I/O are isolated from each other for voltages up to 250VAC or DC on a continuous basis 
(unit will withstand a 1500V AC dielectric strength test for one minute without breakdown). The carrier is 
designed to be used with isolated AcroPack modules. 
 

Содержание ACPS3310

Страница 1: ...rd USER S MANUAL ACROMAG INCORPORATED 30765 South Wixom Road Wixom MI 48393 2417 U S A Tel 248 295 0310 Email solutions acromag com Copyright 2019 Acromag Inc Printed in the USA Data and specification...

Страница 2: ...6 Software Support 6 Windows 6 VxWorks 6 Linux 6 2 PREPARATION FOR USE 7 UNPACKING AND INSPECTION 7 BOARD CONFIGURATION 7 Power and Cooling Considerations 8 Carrier Fuses 9 Isolation Considerations 9...

Страница 3: ...E PROCEDURE 19 WHERE TO GET HELP 19 5 SPECIFICATIONS 20 PHYSICAL 20 Physical Configuration 20 Connectors 20 Isolation 20 Isolated Power 21 Power 21 Fuses 21 CPCI S COMPLIANCE 21 ENVIRONMENTAL 21 EMC C...

Страница 4: ...marks registered trademarks trade names and service marks are the property of their respective owners Radio Frequency Interference Statement This is a Class A product In a domestic environment this pr...

Страница 5: ...ides the capability to distinguish a particular carrier and AcroPack module from others when multiple instances of the same carrier and or module are used in a system JTAG Programming Header A standar...

Страница 6: ...gh level interface to boards eliminating the need to perform low level reads writes of registers and the writing of interrupt handlers VxWorks Acromag provides a software product sold separately consi...

Страница 7: ...s packaging Be aware that failure to comply with these guidelines will void the Acromag Limited Warranty UNPACKING AND INSPECTION Upon receipt of this product inspect the shipping carton for evidence...

Страница 8: ...rature rise above the maximum operating temperature The lack of air circulation within some CPCI S chassis could be a cause for some concern The dense packing of the AcroPack modules to the carrier bo...

Страница 9: ...WARNING This AcroPack carrier is designed to provide isolation between the AcroPack Field I O signals and the host The AcroPack module must also be an isolated AcroPack module to maintain the isolatio...

Страница 10: ...against the back of the carrier connector position the module such that the field I O connector is just above the mating connector Verify that the two connectors are properly aligned Once alignment is...

Страница 11: ...Pack module AcroPack Field I O Connectors The field side connector of AcroPack modules mate to Samtec SS5 50 3 00 L D K TR socket connectors on the carrier board This provides excellent connection int...

Страница 12: ...served isolation 27 27 Reserved isolation 8 30 30 Field I O 15 42 29 29 Field I O 16 32 32 Reserved isolation 31 31 Reserved isolation 9 34 34 Field I O 17 43 33 33 Field I O 18 36 36 Reserved isolati...

Страница 13: ...1 61 Field I O 32 64 64 Reserved isolation 63 63 Reserved isolation 17 66 66 Field I O 33 51 65 65 Field I O 34 68 68 Reserved isolation 67 67 Reserved isolation 18 70 70 Field I O 35 52 69 69 Field I...

Страница 14: ...4 94 Field I O 47 58 93 93 Field I O 48 96 96 Reserved isolation 95 95 Reserved isolation 25 98 98 Field I O 49 59 97 97 Field I O 50 100 100 Reserved isolation 99 99 Reserved isolation Mini PCIe Conn...

Страница 15: ...LED_WPAN LED_WLAN LED_WWAN W_DISABLE COEX1 COEX2 UIM_C4 UIM_C8 UIM_VPP UIM_RESET UIM_CLK UIM_DATA UIM_PWR 2 TDI is tied to TDO on modules that do not use JTAG 3 5 12 and 12 Volt power supplies have be...

Страница 16: ...GND 02 GND reserved reserved 03 1_USB3_Rx 1_USB3_Rx GA1 04 GND PE_CLKIN PE_CLKIN 05 1_PE_Rx00 1_PE_Rx00 GND 06 GND 1_PE_Rx02 1_PE_Rx02 G H I 01 12V 12V GND 02 GND RST WAKE_OUT 03 SATA_SDI SATA_SDO GA...

Страница 17: ...alent The pin assignment for P9 is shown in Table 5 A bypass circuit is included that will detect a vacant AcroPack site and close a switch to bypass the TDI and TDO signals A CPLD on the carrier is i...

Страница 18: ...TCK pin on all target ISP devices sharing the same data stream TDO JTAG Test Data Out This pin is the serial data stream received from the TDO pin on the last device in a JTAG chain TDI JTAG Test Data...

Страница 19: ...n the geographical addressing signals GA0 GA3 from the backplane The slot address is 5 bits long and consists of 1 bit to identify the site on the carrier where the AcroPack modules is installed and 4...

Страница 20: ...MT repair and service tools are used Further Acromag has automated test equipment that thoroughly checks the performance of each board Please refer to Acromag s Service Policy Bulletin or contact Acro...

Страница 21: ...00 mm Board thickness 0 063 inches 1 60 mm Max component height 0 402 inches 10 21 mm Max component height under AcroPack modules 0 0789 inches 2 00 mm Weight 5 57 oz 158 g Connectors P1 CPCI S 72 pin...

Страница 22: ...D1212A XP Power JCE Series 6 Watt 12 VDC 250mA JCE0612D12 TRACO POWER TEN 6N Series 6 Watt 12 VDC 250mA TEN 6 1222N Power Board power requirements are a function of the installed AcroPack modules This...

Страница 23: ...per IEC 61000 4 6 Emissions per EN61000 6 4 Enclosure Port per CISPR 16 Low Voltage AC Mains Port per CISPR 16 Note This is a Class A product Vibration and Shock Standard The ACPS3310 is designed to p...

Страница 24: ...tents are lost when power is removed Yes No Non Volatile Memory Does this product contain Non Volatile memory i e Memory of whose contents is retained when power is removed Yes No Type EEPROM FLASH et...

Страница 25: ...tPCI Serial Carrier Board 25 7 REVISION HISTORY The following table shows the revision history for this document Release Date Version EGR DOC Description of Revision 26 JUL 2018 ENZ Preliminary releas...

Отзывы: