Acromag 655T Series Скачать руководство пользователя страница 9

Series 655T/656T Transmitter User's Manual                                                                                          mV/TC Input 
___________________________________________________________________________________________ 
 

 - 9 - 

 

OUTPUT SPECIFICATIONS 

 
DC Process Current Output Specifications: 

Output Range: 

 4 to 20mA DC, 3.8 to 23.8mA range typical. 

Output Ripple:

  Less than 

0.1% of output span. 

Output Limiting:

  Output current is limited to less than 

25mA, typical. 

Output Maximum Current:

  23.8mA typical, 25mA 

maximum. 

Output Compliance:

 12V Minimum, 13V Typical, with a 24V 

supply and 20mA loop current. 

Output Resolution:

  The output stage resolves to 1 part in 

6546 for a 4 to 20mA output span.  Note that input 
resolution is limited to 0.1

C (TC inputs).  Thus, the 

effective resolution is controlled by the output stage for 
TC input spans greater than 655

C (resolves 1 part in 

6546), or the input stage for TC input spans less than 
655

 (resolves to 0.1

C).  For most voltage input ranges, 

the effective resolution is controlled by the output stage 
(resolves to 1 part in 6546). 

 
General Output Specifications: 

Response Time: 

 For a step change in input signal, the 

analog output reaches 98% of final value in less than 
980ms typical, with a 500

 load.  Response time will 

vary with load resistance. 

Accuracy:  

Typical TC accuracy is listed in Table 5.  Voltage 

accuracy is better than 

0.1% of output span (

16uA), 

typical.  CJC resolution may degrade accuracy for 
smaller input spans.  This error includes the combined 
effects of isolator repeatability, hysteresis, terminal point 
linearity, and adjustment resolution.  It does not include 
sensor error.  Relative accuracy will vary with calibrated 
input span and effective resolution. 

Accuracy Versus Temperature:

  Better than ±0.010% of 

input span per 

F (

0.018% per 

C or 

180ppm/

C) over 

the ambient temperature range for reference test 
conditions.  This specification includes the combined 
effects of zero and span drift over temperature. 

Output Power Supply: 

 12-36V DC Class 2, 24mA.  The 

supply voltage must be chosen to provide full-scale 
current to the load (0.020*R), plus 12V to the isolator 
terminals, plus any line drop.  Reverse polarity protection 
is included. 

Power Supply Effect: 

 Less than 

0.001% of output span 

effect per volt DC change, or 

0.015% of output span 

effect per volt peak-to-peak of 60Hz/120Hz power supply 
ripple.

 

Output Load Resistance Effect:

  Less than 

0.01% of 

output span effect for 

100

 change in load resistance. 

Load Resistance Range Equation:

  R

load

 (Maximum) = 

(V

supply

 - 12V)/0.020A (assuming negligible line drop).  At 

a 24V DC supply, R

load

 = 0-600

Note: 

 For sensitive applications with high-speed 

acquisition rates, high frequency noise may be reduced 
considerably by simply placing a 0.1uF capacitor directly 
across the load. 

Output Conversion Rate:

  Every 50ms or 20 conversions 

per second (millivoltage ranges), every 306ms or 3 
conversions per second (thermocouple ranges). 

 

APPROVALS (-xxx0) 

 
0

:    

cULus Listed 

 

Hazardous Locations: Class I ; Division 2; Groups A, B, C, D. 

 
 

ENCLOSURE/PHYSICAL SPECIFICATIONS 

 

Unit is packaged in a general purpose plastic enclosure that is 
DIN rail mountable for flexible, high density (approximately 1” 
wide per unit) mounting.  See Enclosure Dimensions Drawing 
4501-780 for details. 
 

Dimensions

:  Width = 1.05 inches, Height = 4.68 inches, Depth 

= 4.35 inches (see Drawing 4501-780). 

DIN Rail Mounting (-xx0x):

  

DIN rail mount, Type EN50022; “T” 

rail (35mm). 

Connectors:

  Removable plug-in type terminal blocks; Current/ 

Voltage Ratings: 15A/300V;  Wire Range: AWG #14-24 solid 
or stranded;  Separate terminal blocks are provided for each 
I/O channel. 

Case Material:

  Self-extinguishing NYLON type 6.6 polyamide 

thermoplastic, UL94 V-2, color beige; general purpose NEMA 
Type 1 enclosure. 

Printed Circuit Boards:

  Military grade FR-4 epoxy glass. 

Shipping Weight: 

1 pound (0.45 Kg) packed. 

 
 

ENVIRONMENTAL SPECIFICATIONS 

 
Operating Temperature:  

-25

C to +75

C (-13

F to +167

F), 

Temperature Code: T4. 

Storage Temperature:  

-40

C to +85

C (-40

F to +185

F). 

Relative Humidity:

  5 to 95%, non-condensing. 

Isolation:  

Inputs, outputs, and channels are isolated from each 

other for common-mode voltages up to 250VAC, or 354V DC 
off DC power ground, on a continuous basis (will withstand 
1500VAC dielectric strength test for one minute without 
breakdown).  This complies with test requirements outlined in 
ANSI/ISA-82.01-1988 for the voltage rating specified.  

Installation Category:

  Designed to operate in an Installation 

Category for use in pollution degree 2.

 

Radiated Field Immunity (RFI):

  Designed to comply with 

IEC1000-4-3 Level 3 (10V/M, 80 to 1000MHz AM & 900MHz 
keyed) and European Norm EN50082-1. 

Electromagnetic Interference Immunity (EMI):

  No output shift 

will occur beyond 

0.25% of span, under the influence of EMI 

from switching solenoids, commutator motors, and drill 
motors. 

Electrical Fast Transient Immunity (EFT):

  Complies with 

IEC1000-4-4 Level 3 (2KV) and European Norm EN50082-1. 

Electrostatic Discharge (ESD) Immunity:  

Complies with 

IEC1000-4-2, Level 3 (8KV/4KV air/direct discharge) to the 
enclosure port and European Norm EN50082-1. 

Surge Immunity:  

Complies with IEC1000-4-5 Level 3 (2.0KV) 

and European Norm EN50082-1. 

Radiated Emissions:  

Meets or exceeds European Norm 

EN50081-1 for class B equipment.

 

Содержание 655T Series

Страница 1: ...itters mV TC Input USER S MANUAL ACROMAG INCORPORATED 30765 South Wixom Road Wixom MI 48393 2417 U S A Tel 248 295 0880 Fax 248 624 9234 Copyright 2000 Acromag Inc Printed in the USA Data and specific...

Страница 2: ...tions Output Enclosure Approvals1 Factory Configuration2 655T 06003 C 656T 06003 C 656T E600 C Notes Table 1 1 Approvals cULus Listed Hazardous Locations Class I Division 2 Groups A B C D See specific...

Страница 3: ...SE UNPACKING AND INSPECTION Upon receipt of this product inspect the shipping carton for evidence of mishandling during transit If the shipping carton is badly damaged or water stained request that th...

Страница 4: ...nsmitter accuracy Ripple Noise Power supply ripple at 60Hz 120Hz is normally reduced at the load by the transmitter The ripple at the load will generally be less than 0 02 of span per volt peak to pea...

Страница 5: ...switch 12 must be set ON to unlock the front panel Z FS toggle switches After setting the DIP switches as required for your application you may optionally re scale your input range to the output 4mA a...

Страница 6: ...of increment or decrement Reverse Acting Outputs A reverse acting output can be easily obtained by using the Up Down toggle to adjust the output level accordingly For a reverse acting output you woul...

Страница 7: ...20 878 18 504 13 008 1800 13 585 5 0 SERVICE AND REPAIR CAUTION Risk of Electric Shock More than one disconnect switch may be required to de energize the equipment before servicing SERVICE AND REPAIR...

Страница 8: ...pecifications Thermocouple User configured for the eight types of thermocouples shown in Table 5 Model 656T E600 units only support J K TC types plus the 0 125mV input range Linearization separately e...

Страница 9: ...igible line drop At a 24V DC supply Rload 0 600 Note For sensitive applications with high speed acquisition rates high frequency noise may be reduced considerably by simply placing a 0 1uF capacitor d...

Страница 10: ...DN direction to lower the full scale output level NOTE Note that the zero and full scale adjustments take effect immediately and are saved to non volatile memory after 15 seconds of toggle switch inac...

Страница 11: ...OOPS AND MEASUREMENT ERROR NOTE 1 SHIELDED CABLE 4 20mA NOTE 1 WARNING TB2 or TB3 Acromag CHAN 1 DC SUPPLY 12 36V DC SOURCE VOLTAGE DC SUPPLY 4 20mA SHIELDED CABLE 12 36V DC INPUT CHAN 2 TB2 or TB3 MO...

Страница 12: ...tionON Lock ON 8 9 10 11 12 ConfigurationUNLOCKED 1 ConfigurationLOCKED LinearizationOFF LinearizationON 0 0 1 0 0 1 0 0 1 0 0 0 1 1 1 1 1 1 1 0 1 1 0 1 1 0 0 0 0 0 0 1 1 0 0 CJC OFF CJC ON TC Break D...

Страница 13: ...___________________________________________________________ 13 Revision History The following table details the revision history for this document Release Date Version EGR DOC Description of Revision...

Страница 14: ...Series 655T 656T Transmitter User s Manual mV TC Input ___________________________________________________________________________________________ 14 Notes...

Отзывы: