Series 655T/656T Transmitter User's Manual                                                                                          mV/TC Input 
___________________________________________________________________________________________ 
 

 - 2 - 

 
Safety Summary - Symbols on equipment: 

 

 

Means “Caution, refer to this manual for additional  
             

information”.

 

 

 
The information contained in this manual is subject to change 
without notice.  Acromag, Inc., makes no warranty of any kind 
with regard to this material, including, but not limited to, the 
implied warranties of merchantability and fitness for a particular 
purpose.  Further, Acromag, Inc., assumes no responsibility for 
any errors that may appear in this manual and makes no 
commitment to update, or keep current, the information contained 
in this manual.  No part of this manual may be copied or 
reproduced in any form, without the prior written consent of 
Acromag, Inc. 
 

Table of Contents

 

Page 

 

 

1.0  INTRODUCTION

 

………………………………..…….. 

DESCRIPTION ………………………………………… 

Key 656T Features………………………………….. 

2.0  PREPARATION FOR USE

 

….……………………….. 

UNPACKING AND INSPECTION ……………………

 

INSTALLATION ……………………………………….. 

Mounting ……………………………………………… 

Electrical Connections ……………………………… 

3.0  MODULE CONFIGURATION

.……………………….. 

DIP SWITCH SETTINGS……………………………… 

ZERO AND SPAN CONFIGURAT

ION………………. 

Table 4: TC Millivoltage Versus Temperature..….. 

4.0  THEORY OF OPERATION

 

………………………….. 

5.0  SERVICE AND REPAIR

 

……………………………… 

SERVICE AND REPAIR ASSISTANCE ……………. 

PRELIMINARY SERVICE PROCEDURE ..…………. 

6.0  SPECIFICATIONS

 

……………………………………. 

MODEL NUMBER DEFINITION……………………… 

INPUT SPECIFICATIONS ……………………………. 

OUTPUT SPECIFICATIONS…………………….……

 

APPROVALS ………………………………………….. 

ENCLOSURE/PHYSICAL SPECIFICATIONS …….. 

ENVIRONMENTAL SPECIFICATIONS….………….. 

CONFIGURATION CONTROLS

..……………………. 

10 

 

List of Drawings

 

Page 

 

 

Simplified Schematic (4501-

777).……………………….… 

11 

Electrical Connections (4501-

778).…..…………….…..…. 

11 

DIP Switch Locations & Settings (4501-

779)………….…. 

12 

Enclosure Dimensions (4501-

780)….………………..…… 

12 

REVISION HISTORY 

 

 

 

 

 

 

  13 

 
 
                  IMPORTANT SAFETY CONSIDERATIONS 

 

 It is very important for the user to consider the possible adverse 
 effects of power, wiring, component, sensor, or software failures 
 in designing any type of control or monitoring system.  This is  
 especially important where economic property loss or human life 
 is involved.  It is important that the user employ satisfactory  
 overall system design.  It is agreed between the Buyer and  
 Acromag, that this is the Buyer's responsibility. 

 

 

 

1.0  INTRODUCTION 

 

These instructions cover the hardware functionality of the 

transmitter models listed in Table 1.  Supplementary sheets are 
attached for units with special options or features. 

 

Table 1:  Models Covered in This Manual 

Series/ 
Input/Type 

-Options/Output/ 
 Enclosure/Approvals

1

 

-Factory  
Configuration

2

 

655T 

-0600

3

 

-C 

656T 

-0600

3

 

-C 

656T 

-E600 

-C 

 
Notes (Table 1): 

1.   Approvals: cULus Listed.  

Hazardous Locations:  Class I; Division 2; Groups A,B,C,D.  
(See specifications). 

2.   Include th

e “-C” suffix to specify factory configuration option.  

Otherwise, no suffix is required for standard configuration. 

3.   Model 655T-0600 units have one I/O channel, while 656T-

0600 transmitters have two independent I/O channels.  
Economy Model 656T-E600 operates the same as 656T-
0600, but only supports the TC type J & K, and 0-125mV 
input ranges, and provides no TC linearization. 

 
 

DESCRIPTION 

 

Series 655T/656T Transmitters are members of the popular 

Acromag transmitter, isolator, and alarm family.  These models 
are simple, low cost, isolated, two-wire transmitters for multi-
range thermocouple or DC voltage input signals, in single (655T), 
and dual (656T) channel configurations.  These models are fully 
reconfigurable via external DIP and toggle switches on the 
module. 

 
These models provide one or two inputs for either DC 

millivolts or thermocouple input signals.  The dual channels of 
Model 656T units operate completely isolated and independent of 
one another.  Thermocouple reference-junction compensation, 
linearization, and open circuit or TC break detection is included.  
Front panel toggle switches are used to facilitate field calibration 
of zero and full-scale.  Side access DIP switches select the input 
range & type, disable/enable TC break, set TC break upscale or 
down-scale, turn CJC On/Off, turn linearization On/Off, and 
lock/unlock zero/full-scale adjustment.  The unit may be 
calibrated for a normal or reverse acting output response. 

 
The module uses a high resolution, low noise, Sigma-Delta, 

Analog to Digital Converter (

-

 ADC) to accurately convert the 

input signal into a digitized value.  An optically isolated PWM 
circuit provides the corresponding process current output.  These 
units contain an advanced technology microcontroller with 
integrated downloadable flash memory and EEPROM for non-
volatile program, configuration, calibration, and parameter data 
storage.  Flexible transmitter functionality, variable range inputs, 
plus convenient switch programming makes this instrument 
extremely versatile over a broad range of applications. 

 
These modules are designed to withstand harsh industrial 

environments.  They feature RFI, EMI, ESD, EFT, and surge 
protection, plus low temperature drift, wide ambient temperature 
operation, and isolation between input and power/output.  They 
also have low radiated emissions per CE requirements. 

!

 

Содержание 655T Series

Страница 1: ...itters mV TC Input USER S MANUAL ACROMAG INCORPORATED 30765 South Wixom Road Wixom MI 48393 2417 U S A Tel 248 295 0880 Fax 248 624 9234 Copyright 2000 Acromag Inc Printed in the USA Data and specific...

Страница 2: ...tions Output Enclosure Approvals1 Factory Configuration2 655T 06003 C 656T 06003 C 656T E600 C Notes Table 1 1 Approvals cULus Listed Hazardous Locations Class I Division 2 Groups A B C D See specific...

Страница 3: ...SE UNPACKING AND INSPECTION Upon receipt of this product inspect the shipping carton for evidence of mishandling during transit If the shipping carton is badly damaged or water stained request that th...

Страница 4: ...nsmitter accuracy Ripple Noise Power supply ripple at 60Hz 120Hz is normally reduced at the load by the transmitter The ripple at the load will generally be less than 0 02 of span per volt peak to pea...

Страница 5: ...switch 12 must be set ON to unlock the front panel Z FS toggle switches After setting the DIP switches as required for your application you may optionally re scale your input range to the output 4mA a...

Страница 6: ...of increment or decrement Reverse Acting Outputs A reverse acting output can be easily obtained by using the Up Down toggle to adjust the output level accordingly For a reverse acting output you woul...

Страница 7: ...20 878 18 504 13 008 1800 13 585 5 0 SERVICE AND REPAIR CAUTION Risk of Electric Shock More than one disconnect switch may be required to de energize the equipment before servicing SERVICE AND REPAIR...

Страница 8: ...pecifications Thermocouple User configured for the eight types of thermocouples shown in Table 5 Model 656T E600 units only support J K TC types plus the 0 125mV input range Linearization separately e...

Страница 9: ...igible line drop At a 24V DC supply Rload 0 600 Note For sensitive applications with high speed acquisition rates high frequency noise may be reduced considerably by simply placing a 0 1uF capacitor d...

Страница 10: ...DN direction to lower the full scale output level NOTE Note that the zero and full scale adjustments take effect immediately and are saved to non volatile memory after 15 seconds of toggle switch inac...

Страница 11: ...OOPS AND MEASUREMENT ERROR NOTE 1 SHIELDED CABLE 4 20mA NOTE 1 WARNING TB2 or TB3 Acromag CHAN 1 DC SUPPLY 12 36V DC SOURCE VOLTAGE DC SUPPLY 4 20mA SHIELDED CABLE 12 36V DC INPUT CHAN 2 TB2 or TB3 MO...