Acromag 651T Series Скачать руководство пользователя страница 9

Ser

ies
 651T

/652T

/653T

 Is
olator

 Us

er

’s

 Manual                                           Pr

oc
es
s

 Cur

rent T

w

o-

W
ire T
rans

m

itter
s

 

___________________________________________________________________________________________ 

 

 - 8

 - 

SNS

12

15

23

26

PWR

INPUT

CH2 OUT

SNS

11

14

13

22

16

21

25

24

PWR

SPAN

CH1 OUT

CHAN 1

MODEL 652T-0600

MODEL 652T-0600

IN+

SNS

IN-

R

12

15

23

26

R

+

IN-

CH1 IN

IN+

CH2 IN

SNS

CH2 OUT

TB1

11

14

13

TB1

22

16

21

TB2

25

24

NOTE 1

NOTE 1

12-36V
DC SUPPLY

Acromag

MODEL 652T-0600 SHOWN

ZERO

CHAN 2

OUTPUT LOOP 2
POWER (GREEN)

MODEL 653T-0600

ZERO

SPAN

OUTPUT LOOP 1
POWER (GREEN)

CH1 OUT

MODEL 651T-0600

NOTE 1

SHIELDED CABLE

NOTE 1

EXAMPLE I/O
CONNECTIONS
(CHANNEL 1)

OUTPUT LOOP 2
ZERO/SPAN ADJUST

SAFETY GUIDELINES MAY REQUIRE THAT THIS DEVICE BE HOUSED IN AN
APPROVED METAL ENCLOSURE OR SUB-SYSTEM, PARTICULARLY FOR
APPLICATIONS WITH VOLTAGES GREATER THAN OR EQUAL TO 75VDC/50VAC.

OUTPUT LOOP 1
ZERO/SPAN ADJUST

I/O CONNECTIONS

(SEE I/O CONNECTIONS OF FOLLOWING PAGE)

4501-727B
FIGURE A

ELECTRICAL CONNECTIONS

IN+

TB2

OUT-

TB2

OUT-

OUT+

IN-

TB1

OUT-

OUT+

OUT+

TB1

+

OUT-

OUT+

THIS MODEL CONTAINS TWO
ISOLATED PROCESS CURRENT
ISOLATION CHANNELS.

REMOVABLE
PLUG-IN TYPE
TERMINAL BLOCKS

4-20mA
CURRENT
SOURCE

NOTE 1:  THIS GROUND CONNECTION IS RECOMMENDED FOR BEST
RESULTS.  IF SENSORS ARE INHERENTLY CONNECTED TO GROUND,
USE CAUTION TO AVOID MAKING ADDITIONAL GROUND CONNECTIONS
WHICH COULD GENERATE GROUND LOOPS AND MEASUREMENT ERROR.

WARNING:
FOR COMPLIANCE TO APPLICABLE SAFETY AND PERFORMANCE STANDARDS,
THE USE OF SHIELDED CABLE IS RECOMMENDED AS SHOWN.  ADDITIONALLY,
THE APPLICATION OF EARTH GROUND MUST BE IN PLACE AS SHOWN IN THIS
DRAWING.  FAILURE TO ADHERE TO SOUND WIRING AND GROUNDING
PRACTICES MAY COMPROMISE SAFETY AND PERFORMANCE.

(SEE I/O CONNECTIONS OF FOLLOWING PAGE)

 

Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Содержание 651T Series

Страница 1: ...service in house repair center WE BUY USED EQUIPMENT Sell your excess underutilized and idle used equipment We also offer credit for buy backs and trade ins www artisantg com WeBuyEquipment REMOTE IN...

Страница 2: ...65 South Wixom Road P O BOX 437 Wixom MI 48393 7037 U S A Tel 248 295 0880 Fax 248 624 9234 Copyright 1999 Acromag Inc Printed in the USA Data and specifications are subject to change without notice 8...

Страница 3: ...t Enclosure Approvals1 651T3 0600 652T3 0600 653T3 0600 Notes Table 1 1 Approvals CE marked UL and cUL listed Hazardous Locations Class 1 Division 2 Groups A B C D See specifications 2 The unit is cal...

Страница 4: ...secure the DIN rail to the mounting surface Units may be mounted side by side on 1 inch centers for limited space applications T Rail 35mm Type EN50022 To attach a module to this style of DIN rail ang...

Страница 5: ...cessible from the front panel of the unit The screwdriver blade used to adjust the potentiometers should not be more than 0 1 inch 2 54mm wide TRANSMITTER ADJUSTMENT PROCEDURE Equipment Required An ac...

Страница 6: ...t acts as a signal splitter with one input driving 2 isolated two wire outputs These isolators are DIN rail mounted with plug in type terminal blocks Units are calibrated via zero and span adjustment...

Страница 7: ...ght 1 pound 0 45 Kg packed APPROVALS xxx0 0 CE marked UL listed UL508 17TH Edition and ANSI ISA 12 12 01 2007 cUL listed Canada Standard C22 2 142 M1987 and 213 M1987 Hazardous Locations Class 1 Divis...

Страница 8: ...1 OUT2 INPUT FILTERING SCREW TERMINAL NUMBER OSCILLATOR ISOLATED CHANNEL 2 652T SINGLE ISOLATED INPUT TWO ISOLATED OUTPUTS 653T 4501 726B ISOLATED CHANNEL 1 651T IS ISOLATED FROM INPUT TO OUTPUT 652T...

Страница 9: ...GREATER THAN OR EQUAL TO 75VDC 50VAC OUTPUT LOOP 1 ZERO SPAN ADJUST I O CONNECTIONS SEE I O CONNECTIONS OF FOLLOWING PAGE 4501 727B FIGURE A ELECTRICAL CONNECTIONS IN TB2 OUT TB2 OUT OUT IN TB1 OUT O...

Страница 10: ...NNECTION W OPTIONAL OUTPUT SENSE CONNECTION ISOLATED CHANNEL 1 TYPICAL CALIBRATION CONNECTIONS CONNECTIONS AT CHANNEL 1 MODEL 651T 652T 653T INPUT OUTPUT R XMTR IN DC SUPPLY SHIELDED CABLE OUTPUT CURR...

Страница 11: ..._ 10 Acromag SPAN PWR CHAN 2 3 75 95 3 SPAN ZERO R ZERO CHAN 1 PWR L C T RAIL DIN MOUNTING DIN EN 50022 35mm 59 4 2 34 SCREWDRIVER SLOT FOR REMOVAL FROM T RAIL 3 90 99 1 4 35 110 5 4501 728A NOTE ALL...

Страница 12: ...service in house repair center WE BUY USED EQUIPMENT Sell your excess underutilized and idle used equipment We also offer credit for buy backs and trade ins www artisantg com WeBuyEquipment REMOTE IN...

Отзывы: