Series 651T/652T/653T Isolator User’s Manual                                           Process Current Two-Wire Transmitters 
___________________________________________________________________________________________ 
 

 - 5 - 

 

5.0  SERVICE AND REPAIR 
 

WARNING:

  To prevent electric shock, be sure to remove the 

I/O signals/power before unplugging the terminals to uninstall 
the module or before attempting service.  All connections 
should be made with power removed.

 

 
 

SERVICE AND REPAIR ASSISTANCE 

 

This module contains solid-state components and requires no 

maintenance, except for periodic cleaning and isolator zero and 
span verification.  Since Surface Mounted Technology (SMT) 
boards are generally difficult to repair, it is highly recommended 
that a non-functioning module be returned to Acromag for repair.  
The board can be damaged unless special SMT repair and 
service tools are used.  Further, Acromag has automated test 
equipment that thoroughly checks and calibrates the performance 
of each module.  Please refer to Acromag’s Service Policy 
Bulletin, or contact Acromag for complete details on how to 
obtain service parts and repair. 
 
 

PRELIMINARY SERVICE PROCEDURE 

 

Before beginning repair, be sure that all installation and 

configuration procedures have been followed and that the unit is 
wired properly.  Verify that power is applied and that your power 
supply voltage is sufficient to supply full-scale current into the 
load (0.020*R), plus 12V at the module terminals, plus any line 
drop.  The output sense resistor can be used to monitor the loop 
current without breaking the loop by connecting a DVM between 
output SNS and OUT-, and measuring the corresponding voltage 
drop across 10

Ω

.  If you continue to have a problem with the unit 

after making these checks, then an effective and convenient fault 
diagnosis method is to exchange the questionable module with a 
known good unit. 

 
Acromag’s Application Engineers can provide further 

technical assistance if required.  When needed, complete repair 
services are available from Acromag. 
 
 

6.0 SPECIFICATIONS 

 

651T-0600

, Single, 2-Wire, Process Current Isolation Channel 

652T-0600

, Dual, 2-Wire, Process Current Isolation Channels 

653T-0600

, Single Input, Dual Isolated 2-Wire Current Outputs

 

 

General:

  The Series 65xT transmitter/isolators accept 4 to 

20mA process current input signal(s), provide input-to-output 
and channel-to-channel isolation, and generate 4 to 20mA 
output signal(s).  These isolators are connected in two-wire 
fashion with the output signal and power sharing the same 
leads.  The 653T unit acts as a signal splitter, with one input 
driving 2 isolated two-wire outputs.  These isolators are DIN-
rail mounted with plug-in type terminal blocks.  Units are 
calibrated via zero and span adjustment potentiometers 
accessible from the front panel of the unit.  Each channel 
includes a green LED to indicate loop power. 

 

 

MODEL NUMBER DEFINITION 
 

Transmitters are color coded with a white label.  The prefix “6” 
denotes Series 600 Isolators, “5” denotes two-wire power 
versions, “X” denotes the isolation channel configuration, the “T” 
suffix specifies that this device is a transmitter/isolator. 

 
65xT:

   Two-wire, single channel (651T), dual channel (652T), 

and single input/dual output (653T), transmitter/isolators 
for process current I/O. 

 

-0600:

  The four digits of this model suffix represent the following 

options, respectively: 

 

0 = Option specifier - no option; 
6 = Output is DC current; 
0 = Enclosure is DIN rail mounted; 
0 = Approvals: CE marked, UL and cUL listed. 
      Hazardous Locations: Class 1; Division 2; Groups A,   
      B, C, D 

 
 

INPUT SPECIFICATIONS 

 

The following paragraphs summarize this model’s input type and 
range, plus applicable specifications. 
 

DC (Process) Current:

 4 to 20mA DC, 3 to 25mA range typical. 

Reference Test Conditions:

  4 to 20mA input/output current; 

R-load = 500

Ω

; Supply = 24VDC; Ambient = 25

°

C. 

Input Reverse Polarity Protection: 

 Diode included.

 

Input Overvoltage Protection:

  Bipolar Transient Voltage 

Suppressers (TVS), 5.6V working, 7.6V clamp level typical. 

Input Forward Voltage Drop:

  Less than 1.5V typical for 

651T & 652T units, or 3V typical for 653T units. 

 
General Input Specifications 

Common Mode Noise Rejection:

  100dB at 60Hz, typical. 

Normal mode Noise Rejection: 

 -5dB at 60Hz, with a 100

Ω

 

source, typical. 

Input Bandwidth:

  -3dB at 45Hz, typical, with 500

Ω

 load. 

 
 

OUTPUT SPECIFICATIONS 

 
DC Process Current Output Specifications: 

Output Range: 

 4 to 20mA DC, 3 to 25mA range typical. 

Output Ripple:

  Less than 

±

0.1% of output span. 

Output Limiting:

  Output current is limited to less than 

36mA, typical. 

 
General Output Specifications: 

Response Time: 

 For a step change in input signal, the 

output reaches 98% of final value in less than 15ms 
typical, with 500

Ω

 load.  Response time will vary with 

load resistance. 

Accuracy:  

Better than 

±

0.1% of output span (

±

16uA) typical.  

This error includes the combined effects of isolator 
repeatability, hysteresis, terminal point linearity, and 
adjustment resolution.  It does not include sensor error. 

Accuracy Versus Temperature:

  Better than ±0.006% of 

input span per 

°

F (

±

0.01% per 

°

C) over the ambient 

temperature range for reference test conditions.  This 
specification includes the combined effects of zero and 
span drift over temperature. 

Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Содержание 651T Series

Страница 1: ...service in house repair center WE BUY USED EQUIPMENT Sell your excess underutilized and idle used equipment We also offer credit for buy backs and trade ins www artisantg com WeBuyEquipment REMOTE IN...

Страница 2: ...65 South Wixom Road P O BOX 437 Wixom MI 48393 7037 U S A Tel 248 295 0880 Fax 248 624 9234 Copyright 1999 Acromag Inc Printed in the USA Data and specifications are subject to change without notice 8...

Страница 3: ...t Enclosure Approvals1 651T3 0600 652T3 0600 653T3 0600 Notes Table 1 1 Approvals CE marked UL and cUL listed Hazardous Locations Class 1 Division 2 Groups A B C D See specifications 2 The unit is cal...

Страница 4: ...secure the DIN rail to the mounting surface Units may be mounted side by side on 1 inch centers for limited space applications T Rail 35mm Type EN50022 To attach a module to this style of DIN rail ang...

Страница 5: ...cessible from the front panel of the unit The screwdriver blade used to adjust the potentiometers should not be more than 0 1 inch 2 54mm wide TRANSMITTER ADJUSTMENT PROCEDURE Equipment Required An ac...

Страница 6: ...t acts as a signal splitter with one input driving 2 isolated two wire outputs These isolators are DIN rail mounted with plug in type terminal blocks Units are calibrated via zero and span adjustment...

Страница 7: ...ght 1 pound 0 45 Kg packed APPROVALS xxx0 0 CE marked UL listed UL508 17TH Edition and ANSI ISA 12 12 01 2007 cUL listed Canada Standard C22 2 142 M1987 and 213 M1987 Hazardous Locations Class 1 Divis...

Страница 8: ...1 OUT2 INPUT FILTERING SCREW TERMINAL NUMBER OSCILLATOR ISOLATED CHANNEL 2 652T SINGLE ISOLATED INPUT TWO ISOLATED OUTPUTS 653T 4501 726B ISOLATED CHANNEL 1 651T IS ISOLATED FROM INPUT TO OUTPUT 652T...

Страница 9: ...GREATER THAN OR EQUAL TO 75VDC 50VAC OUTPUT LOOP 1 ZERO SPAN ADJUST I O CONNECTIONS SEE I O CONNECTIONS OF FOLLOWING PAGE 4501 727B FIGURE A ELECTRICAL CONNECTIONS IN TB2 OUT TB2 OUT OUT IN TB1 OUT O...

Страница 10: ...NNECTION W OPTIONAL OUTPUT SENSE CONNECTION ISOLATED CHANNEL 1 TYPICAL CALIBRATION CONNECTIONS CONNECTIONS AT CHANNEL 1 MODEL 651T 652T 653T INPUT OUTPUT R XMTR IN DC SUPPLY SHIELDED CABLE OUTPUT CURR...

Страница 11: ..._ 10 Acromag SPAN PWR CHAN 2 3 75 95 3 SPAN ZERO R ZERO CHAN 1 PWR L C T RAIL DIN MOUNTING DIN EN 50022 35mm 59 4 2 34 SCREWDRIVER SLOT FOR REMOVAL FROM T RAIL 3 90 99 1 4 35 110 5 4501 728A NOTE ALL...

Страница 12: ...service in house repair center WE BUY USED EQUIPMENT Sell your excess underutilized and idle used equipment We also offer credit for buy backs and trade ins www artisantg com WeBuyEquipment REMOTE IN...

Отзывы: