background image

 

Blood Glucose Control Solution 

Package Insert

 

 

REF G125-122

 

English

 

PRINCIPLE AND INTENDED USE 

The 

On Call

®

 

Vivid

 Control Solution contains a known concentration of glucose. It is used to confirm that 

your 

On Call

®

 

Vivid

 Test Strips and 

On Call

®

 

Vivid

 

or 

On Call

®

 

Vivid Pal

 Blood Glucose Meter are 

working together properly and that you are performing the test correctly. 

 
You should perform a quality control test: 

  Before you first use your meter to familiarize yourself with its operation. 

  Before using a new vial of test strips. 

  When you suspect that the meter or test strips are not working properly. 

  When you suspect that your test results are inaccurate, or if they are inconsistent with how you feel. 

  If you suspect your meter is damaged. 

  At least once a week. 

  After cleaning your meter. 

Three levels of control solution are available labeled Control Solution 0, Control Solution 1 and Control 
Solution 2. Control Solution 1 is sufficient for most all self-testing needs. If you think your meter or strips 
may not be working correctly, you may also want to do level 0 or level 2 test. 

COMPOSITION 

Control solution 0 contains less than 0.1% glucose (active ingredient), Control solution1 contains less 
than 0.2% glucose (active ingredient) and Control Solution 2 contains less than 0.4% glucose (active 
ingredient), all with preservatives in an aqueous based mixture. 

STORAGE AND HANDLING 

  Store the control solution at room temperature, 2-30°C (36-86°F). 

  Do not refrigerate or freeze. 

  If the control solution is cold, do not use until it has warmed to room temperature. 

  Use before the unopened expiration date that is shown on the bottle. 

Note: All expiration dates are printed in Year-Month format. 2013-01 indicates January, 2013. 

  Each bottle of control solution can be used for 6 months after you first open it. The control solution 

will expire 6 months after the bottle is opened for the first time. Record this opened expiration date 
on the bottle label. 

PRECAUTIONS 

 For

 in vitro

 diagnostic use. The control solution is for testing only outside the body. Do not swallow or 

inject. For self-testing and professional use. 

  Shake well before using. 

  Control solution tests are specified to be accurate only when tested between 10 and 40°C 

(50-104°F). 

  The control ranges shown on the test strip vial are not a recommended range for your blood glucose 

level. Your personal blood glucose target ranges should be determined by your diabetes healthcare 
professional. 

  Do not touch the end of the test strip to the control solution bottle. This could cause contaminants to 

enter the control solution bottle. 

 Use 

only 

On Call

®

 

Vivid

 brand control solution with your 

On Call

®

 

Vivid

 

or 

On Call

®

 

Vivid Pal

 brand 

meter and 

On Call

®

 

Vivid 

Test Strips.

 

MATERIALS PROVIDED 

 Control Solution 

 Package Insert 

MATERIALS REQUIRED BUT NOT PROVIDED 

 Meter 

 Test 

Strips 

INSTRUCTIONS FOR USE 

1.  Insert a new test strip to turn on the meter. Refer to your meter’s User’s Manual details on how to 

record the result as a quality control test and for further details on operating the meter. 

2.  Shake the control solution bottle thoroughly. 
3.  Squeeze the control solution bottle gently and discard the first drop. If the tip clogs, tap the tip gently 

on a clean, hard surface, shake again, and then use. 

4.  Squeeze out a second small drop on a clean nonabsorbent surface. Touch the sample tip of the test 

strip to the control solution drop and ensure the strip get sufficient sample.   

Notes: 

Do not apply control solution to the test strip directly from the bottle. 

If the control solution sample does not completely fill the check window, do not add a second 
drop. Discard the test strip and start over with a new test strip. 

5.  Read the result from the meter display. 

EXPECTED RESULTS 

Control solution test results should be within the control range. The ranges for CTRL 0, CTRL 1 and 
CTRL 2 are displayed on the test strip vial (or on the foil pouch). For confirmation of results, Control 
Solution 0 tests should fall within the CTRL 0 range, Control Solution 1 tests should fall within the CTRL 
1 range, and Control Solution 2 tests should fall within the CTRL 2 range. If the test results with control 
solution fall within the specified control range, it indicates your Blood Glucose Monitoring System is 
working properly and you are performing the procedure correctly. 

 
If the control solution test results do not fall within the respective ranges: 

  Check the expiration date of the test strip and control solution. Make sure that neither the test strip 

vial nor the control solution bottle has been opened for more than 6 months. Discard any expired test 
strips or control solution. 

  Confirm the temperature in which you are testing is between 10 and 40°C (50-104°F). 

  Make sure that the test strip vial and the control solution bottle have been tightly capped. 

  Confirm that you are using 

On Call

®

 

Vivid

 brand control solution. 

  Make sure that you followed the test procedure correctly. 

After checking all of the conditions listed above, repeat the control solution test with a new test strip. If 
your results still fall outside the range indicated on the test strip vial label or on the foil pouch, your meter 
may not be working properly. DO NOT use the system to test blood. Contact your distributor for help. 
For complete instructions, please refer to the User’s Manual included with your meter. For additional 
questions or issues with this product, please contact your distributor for help.   

 

 

 

INDEX OF SYMBOLS 

 

Consult instructions for 
use 

 

Use by 

Authorized 
Representative 

For 

in vitro 

diagnostic use 

only 

 

Lot Number 

 

Control Range 

Store between 2-30°C 
(36-86°F) 

 

Manufacturer 

REF

 

Catalog # 

 
 
 
 

 
 
 

 

Number: 1150741201 

 

Effective date: 2014-

03-03

 

 

MDSS GmbH 

Schiffgraben 41 

30175 Hannover, Germany

0123

ACON

Laboratories, Inc. 

10125 Mesa Rim Road 
San Diego, CA 92121, USA 

 

www.acondiabetescare.com 

Отзывы: