26
Product description
4.4.7 Fuses
CAUTION
If the accumulator fuse must be exchanged, this may only
be carried out by an electrician.
Accumulator fuse
The accumulator fuse safeguards the fuse against reverse polarity
of the accumulator. If the fuse responds, cabling of the accumulator
must be checked and a new fuse be inserted. Fuse value: 2.5 A
delay fuse.
Electric circuit fuse
The automatic antiflood protection system does not have a mains
fuse in the form of a lead fuse. A fuse is integrated in the primary
circuit of the mains transformer in the form of a thermic switch. In
case the electronics are defective, this switch opens within shortly
upon reaching a temperature of 120°C. If this happens, a serious
defect of the control is existent.
A damage of electric circuit fuse is signalled as accumulator fault.
The red LED 4 flashes every 4 seconds, and additionally a warning
signal sounds every 2 seconds. It must be handed over to the
manufacturer for repair (
chapter 9.2).