1. Safety considerations

The safety guidelines in this chapter are to 
be read before using the separator. Serious 
injuries or death could occur as a result of 
misuse.

1.1 Designated use

1.1.1 Areas of Application

Oleopator separators are designed 
to remove mineral light liquids from 
wastewater.

Applications where mineral oils or mineral 
light liquids are able to enter the sewer 
system should have separator systems 
connected downstream from drainage 
collection points. Such applications include 
petrol stations, parking lots, roadways, car 
washes, engine washes, garages, vehicle 
recycling, scrap yards, fueling stations, tank 
pits and transformer stations. 

Stormwater from areas where no light 
liquids accumulate, such as roofs and 
courtyards, should not be fed into 
separator.

Separators should be installed such that 
no light liquids can escape in the event 

of backflow from the sewer or automatic 
closure of the float. An automatic alarm 

may be required. Regulations may vary by 
state.

1.1.2 Limitations

The separators are not to be installed for 
residential wastewater.

When delivering waste water into the public 
sewer system, the local hydrocarbon limits 
should be observed. Further treatment may 
be required.

1.1.3 Foreseeable misuse

No substances that pollute the water or limit 

the functionality of the separator should be 
introduced into the separator.

This is particularly important in regard to:

  wastewater containing feces,

  wastewater containing animal or 

vegetable greases,

  wastewater in which a considerable 

amount of stable emulsions is present.

1.2 Qualifications of personnel

All work performed on the separator 
equipment is to be carried out by trained 
personnel.

1.3 Personal safety equipment

Personal safety equipment is necessary for 
a variety of works on the separator. 

1.4 Responsibility of owner

The owner is responsible for complying with 
the following points:

• 

Only operate the separator according to 
regulations and in proper condition

• 

Ensure that function of protection 

devices is not impaired

• 

Adhere to a scheduled maintenance 
program and immediately repair faults. 
Only repair faults yourself if the 
measures are described in these 
operating instructions. Contact ACO for 
all other measures

• 

Inspect data plate on the separator for 
completeness and legibility

• 

Adequate personal safety equipment 
must be available and used

• 

Provide complete and legible operating 

instructions at the separator’s site of 

installation and training based on this

• 

Only employ qualified and authorized 
personnel.

Health & Safety

Safety instructions are intended to 
prevent damage to equipment or injury to 
personnel and must be read before any 
maintenance is performed. 

The separated oils and any vapors are 

flammable and/or combustible so care 

must be taken whenever the system is 
opened.

  All safety instruction labels must be 

replaced if they become detached or 
illegible.

  Gas concentrations MUST be tested 

before entering the separator; 

breathing apparatus is recommended 
for all personnel entering separator. 

  Safety lines, harness and radios/

whistles are advised if entering 
separator.

  Smoking and naked lights are 

strictly forbidden anywhere in area 
surrounding the system.

  Installed devices (e.g. baffles, 

inlet and outlet parts, coalescence 
element, etc.) are intended for 
operation of separator system and 

are not load bearing - they must 

not be used as steps, footholds or 
resting places for cleaning equipment 
etc. 

  The separator system is defined 

as a zone 0 explosion hazard area. 

Only authorized, properly trained, 
personnel are permitted to perform 
work on the electrical components of 
the separator (where used). 

  Contact with wastewater containing 

light liquids, e.g. during maintenance, 
can lead to dry, irritated skin, skin 
infections, headaches, dizziness, 
nausea, vision problems, loss of 
consciousness, and, in serious cases, 

death. Ensure proper protective 

clothing is used and immediately 

wash any exposed skin.

Содержание Oleopator P N 3/950

Страница 1: ...oil and sediment separator system ACO Construction Building Products Oleopator P Oil Water Separator Operating Guide 1 Installation 2 Initial set up commissioning 3 Operation 4 Maintenance ACO Enviro...

Страница 2: ...m inflow volume GPM at which point additional inflow bypasses the separator and diverts directly to the outlet pipe Typically most pollutants are washed into the separator during the initial flow so e...

Страница 3: ...___________________________________________________________7 3 Initial Set up 3 1 Prior to filling the system________________________________________________________________________________8 3 2 Filli...

Страница 4: ...r complying with the following points Only operate the separator according to regulations and in proper condition Ensure that function of protection devices is not impaired Adhere to a scheduled maint...

Страница 5: ...n Oleopator separators are intended for in ground installation Care must be taken to determine correct installation to take into account site loadings and traffic patterns Details are provided for lig...

Страница 6: ...3 670 1 78 45 2 75 70 5 90 150 N 3 950 1 78 45 2 75 70 5 90 150 NS6 660 1 57 40 2 56 65 5 71 145 NS6 1210 1 57 40 2 56 65 5 71 145 NS10 1080 1 97 50 2 95 75 6 10 155 Installation situation Super eleva...

Страница 7: ...tions 1 Excavate area 60 wider and 12 deeper than the separator this allows for a 12 aggregate base compacted to Proctor density 97 2 Check level of unit and inverts of inlet outlet pipes 3 Backfill a...

Страница 8: ...er of the LGA Test report Volume of separator and sludge trap Maximum storage volume and maximum thickness of light oil layer Maximum permissible sludge thickness 3 2 2 Filling procedure 1 Ensure inle...

Страница 9: ...nding ground When any of these events occur a signal is sent to the building management system which can send out audio visual and SMS alerts to ensure maintenance can be carried out before the separa...

Страница 10: ...y and clean separator as required see disposal requirements Remove any coarse floating material Inspect all components of alarm system if used Immediately rectify any faults identified Report findings...

Страница 11: ...e units for clean back up spare coalescence unit The dirty coalescence unit can be stored in a water filled container until to prevent dirt drying hard onto unit until it can be cleaned 5 3 Oil Sludge...

Страница 12: ...4764 Fax 440 285 7005 Electronic Contact info acousa com www acousa com Southeast Sales Office 4211 Pleasant Road Fort Mill SC 29708 Toll free 800 543 4764 Fax 803 802 1063 ACO DRAIN The world s lead...

Отзывы: