Troubleshooting
89/ 100
Oleolift-C
6 Troubleshooting
WARNING
Electric shock
■
Work on electrical connections must only be executed by qualified electricians.
■
Disconnect the control unit from the power supply before troubleshooting.
CAUTION
Flooding and risk of infection in case of improper sanitary installation
■
Work on the sanitary equipment must be carried out by qualified personnel
only,
Chapter 1.5 "Personnel qualifications".
■
Only use original spare parts.
■
Only have prefabricated pumping station repairs executed by ACO or an ACO
Service partner,
Chapter Introduction, “ACO Service”.
■
Prevent contact with wastewater and wear protective equipment,
Chapter 1.6 "Personal protective equipment".
■
Never execute work on the connections and pipes unless they are
depressurised.
Burns due to hot surfaces
■
Allow the pump motors to cool.
Faults on the separator
Fault processing, Assembly and operating instructions "idOil -30 - Labkotec".
Malfunctions on the pump station
Malfunction
Cause(s)
Actions
Submerged pump
not functioning
Power consumption too high
(automatic shut-off)
Acknowledge malfunction
If the malfunction remains: Contact ACO
Service
Control unit without power supply
Restore power supply (electrician)
Automatic mode not switched on
Switch on automatic mode
Pump motor is defective
Submerged pump replacement required
(ACO Service)
Submerged pump blocked by foreign bodies
Submerged pump maintenance required
(ACO Service)