PLEASE NOTE!
To ensure proper functioning and use safety, connect the door entry unit to earth by connecting
the grounding terminal on unit’s body with relevant protective installation (PE).
Use a 1 mm
2
cross-section cable (such as LY1,0) to connect the device to power supply. The
maximum cable length for E-lock circuit is 7 m, for power supply circuit - 30 m. Insufficient power
supply, too small cable cross-section and too long connections (voltage drops) may cause device
operation disturbances (such as reset system trip and device restarting, especially when opening the
E-lock).
Connect the 11.5V AC supply voltage to the 12V~ terminals, and if using a DC power supply
unit, connect respectively: +DC of the power supply unit to AC terminals (any of the terminals), and -
DC to GND terminals.
Connect the E-lock with no specific polarity to "ELOCK" terminals: +12V and OUT1 or OUT2, if using
reversible E-lock solder jumper Z4 (on the left side of the board)! When using reversible E-lock,
voltage appears at the "ELOCK" (+12V) output depending on the power supply or transformer used -
use suitable reversible E-lock. It is also possible to use the MOD-DC-12V module for 12VDC power
supply of reversible E-lock if the device is supplied by a 15VDC power supply or a transformer.