40
-
E-lock opening time - 4 [s]
Further door opening function deactivated
Additional INPUT: Open (value "0")
Restoring the factory settings (reset) of the panel from the keypad enabled
Additional range set to from 1 to 255
Code opening without key (except FAM-P-ZS and FAM-PV-ZS)
Code for the bottom button (apartment 1): 1111 (except FAM-P-ZS and FAM-PV-ZS)
Code for the top button (apartment 2): 2222 (except FAM-P-ZS and FAM-PV-ZS)
I/O function active: second gate opening
I/O function active: basic opening having to connect with the apartment
Maximum conversation time: 120 [s]
Maximum number of openings: 3
No proximity fobs stored in memory
XV. MAINTAINING CLEANLINESS
Clean the panel with a damp or antistatic cloth. Do not use any solvents!
IMPORTANT!
When disinfecting panels made of stainless steel, use cleaning agents based on
alcohol only. Any chlorides (which are present in common cleaning products) are harmful to the steel
surface, causing abrasion of its natural protective coating and increasing the risk of corrosion.
XVI. SAFETY RULES FOR INSTALLATION AND USE
Installation should be carried out by a qualified installer
Before removing the panel, turn off the power supply
Avoid unstable power sources and electrical surges as these may cause malfunction or
damage to the equipment
It is mandatory to ground the housing (via the marked terminal on the panel housing) using a
suitable PE.
When trained to operate the system, the user should be briefed that any errors in its
operation may only be corrected by a qualified and authorised person.
Do not expose the panel to any kind of corrosive chemicals, as this may damage the unit.
The applicable OHS regulations must be observed when working on the door
entry system.
XVII. RULES FOR STORING WASTE ELECTRICAL EQUIPMENT
Waste electrical equipment must not be disposed of with other waste. It should be stored in places
designated for this purpose. For this purpose, please contact the responsible institutions or
companies involved in waste recycling - Directive 2002/96/EC of 27.01.2003