ACO FAM-P Скачать руководство пользователя страница 38

38 

 

 

Example settings:

 

Settings

 

Remar

ks

 

Opening the second gate 
using the code ("double 
key"), using the F2 button 
on the uniphone and 
opening the gate without 
making a call (pick up the 
handset and press the "key" 
button three times)

 

Port P1: 
IN=x (x: has no 
effect) 
OUT=0 
NrF=3

 

Port P2: 
IN=x (x: has no 
effect) 
OUT=t (t: time from 
1 to 255 s) 
NrF=2

 

Connect outputs of port P1 and P2 in 
parallel ("N" with "N", "NO" with "NO" ) 

 

For INS-UP720MR and INS-MPR it is 
enough to press the "key" once without 
lifting the handset

 

Opening the second gate 
using the code ("double 
key"), using the F2 button 
on the uniphone and 
activating the E-lock 
without making a call (pick 
up the handset and press 
the "key" button three 
times)

 

Port P1: 
IN=x (x: has no 
effect) 
OUT=t (t: time from 
1 to 255 s) 
NrF=3

 

Port P2: 
IN=x (x: has no 
effect) 
OUT=t (t: time from 
1 to 255 s) 
NrF=2

 

For INS-UP720MR and INS-MPR it is 
enough to press the "key" once without 
lifting the handset

 

Opening the second gate 
using the code ("double 
key"), using the F2 button 
on the uniphone without 
making a call via the third 
wire to the uniphone (only 
INS-720M, INS-720MR)

 

Port P1: 
IN=0 
OUT=t (t: time from 
1 to 255 s) 
NrF=0

 

Port P2: 
IN=x (x: has no 
effect) 
OUT=t (t: time from 
1 to 255 s) 
NrF=2

 

Connect outputs of port P1 and P2 in 
parallel ("N" with "N", "NO" with "NO" )

 

 

Additional number 1 and 2:

 

Optio

n

 

Functionality

 

Additional 

number 1

 

 

Value dialled from numeric keypad for additional number 1

 

Address

 

Physical address to which the panel will call after dialling the additional number

 

Tone

 

Ringtone in the apartment after dialling the additional number

 

 

Number of 

ringtones

 

Number of ringtones during a call to the apartment after dialling the 

additional number

 

Sound volume

 

Volume during a call to the apartment after dialling the additional number

 

 

Auto-opening*

 

Enabling auto-opening (door opening / activating the ELOCK output) after a 

call from the additional number, if a hung-up handset is detected in this 

apartment

 

 

Only calling

 

Disabling a call to a selected apartment (uniphone will only ring, the panel 

will not establish a call after picking up the receiver)

 

 

* If this function is activated and the handset is not hung up during a ringing tone, door opening will 
start automatically after the first ringing tone. If the handset was hung up during the first ringing tone, 
the  panel  works  normally  -  the  handset  can  be  picked  up  and  communication  is  possible.  The 
automatic opening function most commonly used in commercial buildings - letting people in is done 
by simply lifting the handset; after business hours the handset is hung up and the door entry unit 
works normally. 
When the physical addresses of the direct call buttons correspond to additional numbers, they can 
also perform the auto-open function. 

 

If the primary numbers and additional numbers overlap, the latter have priority and calling in these 
cases is always made according to their settings. The access code of an active additional number is 
the code of its physical address. 

Содержание FAM-P

Страница 1: ...1 DOOR ENTRY SYSTEMS EXTENDED USER INSTRUCTION OF FAM P AND FAM PV DOOR ENTRY SYSTEMS 62 002 Suchy Las ul Diamentowa 7 tel fax 61 843 93 71 www aco com pl...

Страница 2: ...ccess code 32 Modification of administrator s initial access code 33 2 SETTING E LOCK OPENING TIME 33 3 SETTING THE NUMBER OF RINGTONES PERMISSION TO CALL APARTMENT 33 4 TURNING ON OFF THE DOOR OPENIN...

Страница 3: ...he opening code resident administrator 2 Setting E lock reset time 3 Setting the number of ringtones permission to call apartment 4 Turning the door opening signal off on 5 Setting one of four rington...

Страница 4: ...c keypad while all settings are available via FAM_P computer program PC Windows Adding deleting archiving transferring between panels proximity fobs can be done using the ACC_v3 software PC Windows In...

Страница 5: ...e customised to individual requirements Adjustable camera position in each direction FAM PV panels Option of image viewing in darkness infrared illumination FAM PV panels Support for proximity key fob...

Страница 6: ...addresses from the bottom address 1 bottom button and successively up to address 6 top button It is also possible after changing the settings via the PC program or directly on the panel numeric keypa...

Страница 7: ...d It is possible to open without having to connect with the apartment In this case on classic uniphones the handset must be picked up and the open button pressed three times on active receivers INS UP...

Страница 8: ...ervice program 9 By default the code table is only added to panels FAM P ZS and FAM PV ZS For other versions of the panel use the code table that is used in the panel master panel or generate it using...

Страница 9: ...sed for opening via an additional module such as an I O module The module is connected to the EXTMOD socket on the panel board and configured via the PC program Automatic opening when calling an addit...

Страница 10: ...XI CDN U signalling module with opening function This module can be used to connect additional devices signalling ringing in the apartment for instance additional bells light bulbs signallers etc for...

Страница 11: ...11 V MOUNTING AND CONNECTING THE PANEL ASSEMBLY The panel should be assembled so as to minimise the impact of adverse weather conditions in particular water Allen key 3 Allen key 3 Allen key 3...

Страница 12: ...s where the camera lens may be exposed to direct perpendicular light from the sun street lamps etc 2 CONNECTING THE PANEL All connections in the installation must be soldered The following wires need...

Страница 13: ...cross section with 1 mm2 wire the distance can be increased to 400 m with 1 5 mm2 wire the distance can be increased to 600 m with 2 5 mm2 wire the distance can be increased to 1000 m Use CDNV RJ45 m...

Страница 14: ...number of receivers in the entire system detailed information can be found in the assembly instructions for the active receivers used In the case of video panels the wiring between the panel and the...

Страница 15: ...stalled in the panel available under the panel terminals When working with reversible E locks voltage appears on ELOCK output depending on transformer or DC power supply used 15VDC use suitable revers...

Страница 16: ...16 3 WIRING DIAGRAMS FOR SINGLE PANEL INSTALLATION Audio panel installation with passive receivers should be connected as per the diagram below Line Line Line Line...

Страница 17: ...17 The installation of audio panels with active receivers should be connected as per the diagram below...

Страница 18: ...18 The installations of audio panel with additional external camera and monitors should be connected as per the diagram below To monitor or splitter...

Страница 19: ...ting the bus cable orange and brown together to DC terminal of the panel in this case the maximum distance between the panel and the monitor is 70m If the additional power supply is connected directly...

Страница 20: ...20 Video Panel with several monitors should be connected as per the diagram below Rozdzielacz Splitter Rozdzielacz Splitter...

Страница 21: ...he panel microphone using the MIC potentiometer adjust the panel speaker volume level using the SPK potentiometer As the MIC and SPK values are set turn the BALANCE potentiometer to determine the posi...

Страница 22: ...of the busy panels Calling and connection topology of Slave panels is shown in the figure below where A is the Master panel B C D E F are Slave panels Only those receivers that are physically connect...

Страница 23: ...he first Familio master panel If several Familio audio panels are installed two bus wires are arranged to the first panel Line Line and Line are connected to the ML terminal of the next panel Line to...

Страница 24: ...or opening codes will be the same for all apartments For proper operation of a system with multiple panels configuration is required for the number and range of apartment addresses that a panel is to...

Страница 25: ...25 Installation of multiple audio panels with active receivers should be connected as per the diagram below...

Страница 26: ...multiple audio panels with additional external camera and multiple monitors should be connected as per the diagram below Rozdzielacz Splitter Kolejne pi tra Next floors Sumator bez kamery Intermediate...

Страница 27: ...27 Installation with multiple video panels and monitors should be connected as per the diagram below Rozdzielacz Splitter Sumator po redni do FAM PV Intermediate combiner for FAM PV...

Страница 28: ...mator po redni do FAM PV Intermediate combiner for FAM PV Rozdzielacz Splitter Rozdzielacz Splitter Rozdzielacz Splitter Sumator po redni do FAM PV Intermediate combiner for FAM PV Sumator bez kamery...

Страница 29: ...er for FAM PV Klatka budynek X Staircase building X Kolejne pietra Next floors Kolejne pietra Next floors Klatka budynek Y Staircase building Y Rozdzielacz Splitter Sumator po redni do FAM PV Intermed...

Страница 30: ...30 Installation with two panels the first of which is an Audio panel should be connected as per the diagram below example 4 Kolejne pietra Next floors Rozdzielacz Splitter...

Страница 31: ...he panel such as individual access codes opening time ringtone etc Service programs are also available to facilitate installation and repairs Basic parameters can be changed using the service menu acc...

Страница 32: ...LE To enter the panel programming function with 0000 installer s code press the key followed by 1507 fixed digits and 0000 1 5 0 7 0 0 0 0 Entering the programming mode is confirmed by an up modulated...

Страница 33: ...ting time from 1s to 10s by entering a digit between 0 and 9 0 means 10 seconds When the panel is reset to factory settings the time is set to 4s 3 SETTING THE NUMBER OF RINGTONES PERMISSION TO CALL A...

Страница 34: ...partment With the receiver s handset lifted press the door opening button three times for passive receivers or press the door opening button once for active receivers The panel will confirm receipt of...

Страница 35: ...dents are set across the whole system For panels with only a numeric keypad the code table number is entered in accordance with the code table supplied Any code table can be generated and name tag pri...

Страница 36: ...code Enabling the restriction of the administrator s code from 6 to 4 digits Doorman s call Enabling the doorman s call by shorting the INPUT Call only button Permitting calls only from direct call b...

Страница 37: ...No 1 or 2 or 3 E lock triggering time as for standard opening Activation of the OUTPUT for a pre set time after pressing the F2 key on the uniphone or after selecting the code preceded by the double p...

Страница 38: ...itional number 1 Address Physical address to which the panel will call after dialling the additional number Tone Ringtone in the apartment after dialling the additional number Number of ringtones Numb...

Страница 39: ...e CDNP INSPIRO i e calls can be made directly from the numeric keypad and the codes must be preceded by the apartment number and the button of the button Once the factory settings are successfully res...

Страница 40: ...surface causing abrasion of its natural protective coating and increasing the risk of corrosion XVI SAFETY RULES FOR INSTALLATION AND USE Installation should be carried out by a qualified installer B...

Страница 41: ...12V between GND and ELOCK terminal Each panel in the system must feature a separate power supply Door opening signalled by the unit but E lock won t work Check E lock or E lock connection to the panel...