36
-
Parameters part 1 and 2:
Option
Functionality
Additional INPUT
Function activated by short-circuiting additional INPUT
Opening delay
INPUTa
Time delay between INPUT contacts shorting and Opening (ELOCK
output activation). The function “Opening after delay" must also be
activated
Opening after
delay
Automatic opening of the E-lock after the end of the countdown from the
“Further door opening pulse" or "INPUT Opening Delay"
Further door
opening pulse
Activation of sending a further door opening pulse to other panels
Offset dir. (Yes+,
No-)
Direction of the offset between the number selected from the numeric
keypad and the physical address sent by the panel (+: adding the offset
value to the physical address; -: subtracting the offset value from the
physical address)
x10 further door
opening delay
Activation of the 10 times multiplier for the "Delay [s]" parameter
value (for the further door opening function)
Reset option
Permission to restore factory settings using panel keys
Camera
from slave
panel
Activate this function in one of the slave panels from which preview of the
image in standby mode is desired (after calling the preview from the
monitors)
4-digit
administrator’s
code
Enabling the restriction of the administrator’s code from 6 to 4 digits
Doorman’s call
Enabling the doorman’s call by shorting the INPUT
"Call only" button.
Permitting calls only from direct call buttons (no calls from numeric
keypad)
Keyless codes
Permitting opening with the resident's code without having to enter the
apartment number and press the "key" button (function available only with
the "Call only button" function activated and only for the first two codes -
direct call buttons)
Reversible opening
Activation of the reversible E-lock
Other parameters
Option
Functionality
Maximum
conversation time
Conversation time in [S]. When the time expires, the panel will automatically
terminate the connection
Maximum number
of openings
The value of this parameter determines the number of times the door can be
opened during the call. When the number is exceeded, the panel will
automatically terminate the connection
I/O module - Port 1 and 2 (Port 2 controls operation of the MINI I/O module):
Option
Functionality
Input value
Parameter value for the input function
Output value
Parameter value for the output function
Function No.
Number of the function executed by an I/O module port (description of the
function can be found, when selected, in the program)
A detailed description of individual functions and an example of their use can be found in the table
on the next page.