35
-
8 - SETTING THE DIRECT CALL BUTTON ADDRESS
Enter the physical address of the receiver to which the direct call button is to be assigned and
confirm with the "
key
" button. Now press the selected button and hold it for about 10 seconds. The
address previously assigned to this button will be overwritten. Entering 0 deactivates the button.
By default, the direct call buttons are:
- bottom key: address "1"
- second key from the bottom: address "2", etc.
9 - ENTERING NEW ACCESS CODE TABLE
This program is used to enter the four-digit number of the code table, used by the panel to
generate 255 individual access codes for residents. Upon entering the table, the procedure of
entering all the codes into the memory is launched and is indicated by an audible signal.
The pre-
set installer’s password remains unchanged (change it in program 7).
Order numbers in the provided code table (1 to 255) always correspond to the physical addresses
in the receivers (irrespective of shifts and other settings).
The function of opening with an access code can be disabled by entering the code table number
"9999".
In systems with multiple units (Master / Slave), by entering the same number of the code table in
each panel, the same access codes for residents are set across the whole system.
For panels with only a numeric keypad, the code table number is entered in accordance with the
code table supplied. Any code table can be generated and name tag printed along with instruction
for residents on
XI. PANEL PROGRAMING VIA A PC
The "FAM_P" software can be downloaded from
. It can be used to
configure all options available in the panel.
Parameter:
Option
Functionality
Uniphone address -
From
Lower value of the physical address limiting the panel range
Uniphone address -
To
Upper value of the physical address limiting the panel range
Offset
Offset value between the number entered using the numeric
keyboard and physical address sent by the panel
Lock time [s]
Door opening time (E-LOCK output activation time)
Delay [s]
Time during which the further door opening function is active after
receiving the further door opening pulse from the upstream panel
Installer's password
The last four digits of the installer’s password
Administrator’s code
Full administrat
or’s code (No. 1 and 2 respectively)
Additional range -
from
Lower value of physical address value limiting the additional range
Additional range - to
Upper value of physical address value limiting the additional range
Button 2
Physical address dialled with second from bottom direct dial button
Button 1 - lower
Physical address dialled with bottom direct call button