7
<Operation part (wireless)>
①
Calibration /
: Switch for calibration. Perform calibration of sound volume
meter (SV-6224) and revolution input circuit.
②
Background noise /
▲
: Switch for background noise measurement. Background noise
(noise before engine start) is measured.
③
Function /
: Switch for selection of functions to enter the setting mode.
Move the cursor using
▼▲
.
④
Measurement A / B
: Switch to change the measurement method.
⑤
Measurement 1 /
▼
: Switch for the 1
st
exhaust noise measurement.
⑥
Print / SET
: Switch for printing. In the case of measurement method A,
lamp will be lit after completion of the 2
nd
measurement and
printing will be started. In the case of measurement method B,
lamp will be lit after completion of the 3
rd
measurement and
printing will be started.
Reprint of the same data is possible by pressing the switch.
⑦
Measurement 2 / Light : Switch for 2
nd
exhaust noise measurement.
Light (backlight of the LCD) will be lit when this switch is pressed.
⑧
Measurement 3 / Feed : Switch for 3
rd
exhaust noise measurement.
It will feed the printer paper when the “Function” switch is
pressed.
⑨
LCD display
: LCD for displaying various functions and measurements.
⑩
Engine revolution speed : When the accelerator is depressed, the status of transition to
inspection revolution speed will be displayed.
When lamp 4 (red) is lit, it is the inspection (setting) revolution
speed.
⑪
Tachometer monitor
: Connector for connecting to external tachometer monitor.
①
②
③
④
⑤
⑥
⑦
⑧
⑨
⑩
⑪