background image

 

 

 

TV LIGHT PANEL 1600

 

 

 

 

LP-1600 BD30

 

 

     

 

                  User Manual   

                        Please read the instructions carefully before use 

 

Содержание LP-1600 BD30

Страница 1: ...TV LIGHT PANEL 1600 LP 1600 BD30 User Manual Please read the instructions carefully before use ...

Страница 2: ...1A ...

Страница 3: ... TABLE OF CONTENTS 1 Safety Instructions 2 Technical Specifications 3 How To Set The Fixture 4 How To Control The Fixture 5 DMX 512 Configuration 6 DMX 512 Connections 7 Troubleshooting 8 Fixture Cleaning ...

Страница 4: ...g as it is fire hazard Use safety cable when fixes this unit Maximum ambient temperature is TA 40 and don t operate it where the temperature is higher than this The unit must be installed in a location with adequate ventilation at least 2 5m from adjacent surfaces Be sure that no ventilation slots are blocked There are no user serviceable parts inside the fixture Do not open the housing or attempt...

Страница 5: ... 3 pin XLR cable plug when connecting them together It features different pre programmed chase patterns 3 Channel modes Voltage AC 100 240V 50 60Hz LED Total 1600pcs CW 800pcs WW 800pcs Power consumption 160W Fuse T 6 3A Dimension 540 x 556 x 115mm Weight 9 7KG 3 Installation The unit should be mounted via its screw holes on the bracket Always ensure that the unit is firmly fixed to avoid vibratio...

Страница 6: ...power consumption of CW WW 3 Button MENU To select the programming functions DOWN To go backward in the selected functions UP To go forward in the selected functions ENTER To confirm the selected functions 4 Color Temperature Adjust the color temperature from 3200k to 6500k 25K as a step When the value is between 4825K and 4875K the green LED indicator will light It means the power consumption of ...

Страница 7: ...ired one is shown on the display Select the function by ENTER button and the display will blink Use DOWN and UP button to change the mode Once the required mode has been selected press ENTER button to setup or it will automatically return to the main functions without any change after idling 30 seconds Back to the functions without any change press MENU button The main functions are shown below ...

Страница 8: ...ange press the MENU button Master Slave mode Press the MENU button up to when the s shown on the display Pressing ENTER button Use DOWN and UP button to select the master mode and slave mode Once select press ENTER button to setup or automatically exit menu mode without any change after 8 seconds To go back to the functions without any change press the MENU button Manual mode Press the MENU button...

Страница 9: ... any change press the MENU button Optically Linear The increase in light intensity appears to be linear as DMX value is increased Square Law Light intensity control is finer at low levels and coarser at high levels Inverse Square Law Light intensity control is coarser at low levels and finger at high levels S curve Light intensity control is finger at low levels and high levels and coarser at medi...

Страница 10: ...button Software version Press the MENU button up to when the is blinking on the display Pressing ENTER button and the display will show the version of software of the unit To go back to the functions press the MENU button again 5 How To Control The Unit You can operate the unit in three ways 1 By master slave function 2 By DMX controller No need to turn the unit off when you change the DMX address...

Страница 11: ...nd the display will blink Use DOWN and UP button to change the DMX512 address Once the address has been selected press and keep ENTER button pressed up to when the display stops blinking or storing automatically 30 seconds later To go back to the functions without any change press the MENU button again If you use please refer to the following diagram to address your DMX512 channel for the first 4 ...

Страница 12: ...hrough to maintain the DMX circuit when one of the units power is disconnected 3 At last fixture the DMX cable has to be terminated with a terminator to reduce signal errors Solder a 120 ohm 1 4W resistor between pin 2 DMX and pin 3 DMX into a 3 pin XLR plug and plug it in the DMX output of the last fixture 4 Each lighting fixture needs to have an address set to receive the data sent by the contro...

Страница 13: ...gside to high voltage cables that may cause damage or interference to DMX interface circuit C No response to the sound 1 Make sure the fixture does not receive DMX signal 2 Check microphone to see if it is good by tapping the microphone D One of the channels is not working well 1 The stepper motor might be damaged or the cable connected to the PCB is broken 2 The motor s drive IC on the PCB might ...

Страница 14: ...13A ...

Страница 15: ...rdance with the provision of the Electromagnetic Compatibility EMC Directive 89 336 EEC EN55014 2 1997 A1 2001 EN61000 4 2 1995 EN61000 4 3 2002 EN61000 4 4 1995 EN61000 4 5 1995 EN61000 4 6 1996 EN61000 4 11 1994 Harmonized Standard EN60598 1 2000 ALL 2000 A12 2002 Safety of household and similar electrical appliances Part 1 General requirements ...

Страница 16: ...15A Innovation Quality Performance ...

Отзывы: