background image

 

12A 

 

 

1.  If  you  using  a  controller  with  5  pins  DMX  output,  you  need  to  use  a  5  to  3  pin 

adapter-cable. 

2.  Connect the fixture together in a “daisy chain” by XLR plug cable from the output 

of  the  fixture  to  the  input  of  the  next  fixture.  The  cable  cannot  be  branched  or 

split to a “Y” cable. Inadequate or damaged cables, soldered joints or corroded 

connectors can easily distort the signal and shut down the system 

3.  The  DMX  output  and  input  connectors  are  pass-through  to  maintain  the  DMX 

circuit when one of the units’ power is disconnected. 

4.  At last fixture, the DMX cable has to be terminated with a terminator to reduce 

signal  errors.  Solder  a  120-ohm  1/4W  resistor  between  pin  2(DMX-)  and  pin 

3(DMX+) into a 3-pin XLR-plug and plug it in the DMX-output of the last fixture. 

5.  Each  lighting  fixture  needs  to  have  an  address  set  to  receive  the  data  sent  by 

the controller. The address number is between 0-511 (usually 0 & 1 are equal to 

1). 

6.   3 pin XLR connectors are more popular than 5 pin XLR. 

3 pin XLR: Pin1: GND, Pin2: Negative signal (-), Pin3: Positive signal (+)   

5 pin XLR: Pin1: GND, Pin2: Negative signal (-), Pin3: Positive signal (+) 

                    Pin4/5: Not Used. 

 

 

8. Troubleshooting   

Following  are  a  few  common  problems  that  may  occur  during  operation.  Here  are  some 

suggestions for easy troubleshooting: 

 

13A 

 

A.  The fixture does not work, no light   

1.  Check the connection of power and main fuse. 

2.  Measure the mains voltage on the main connector. 

 

B.  Not responding to DMX controller 

1.  DMX LED should be on. If not, check DMX connectors, cables to see if link properly. 

2.  If the DMX LED is on and no response to the channel, check the address settings and           

DMX polarity. 

3.  If you have intermittent DMX signal problems, check the pins on connectors or on PCB 

of the fixture or the previous one. 

4.  Try to use another DMX controller.     

5.  Check  if  the  DMX  cables  run  near  or  run  alongside  to  high  voltage  cables  that  may 

cause damage or interference to DMX interface circuit.   

 

C.  Some fixtures don’t respond to the easy controller   

1.  You  may  have  a  break  in  the  DMX  cabling.  Check  the  LED  for  the  response  of  the 

master/ slave mode signal. 

2.  Wrong DMX address in the fixture. Set the proper address. 

 

D.  No response to the sound 

1.  Make sure the fixture does not receive DMX signal. 

2.  Check microphone to see if it is good by tapping the microphone. 

 

E.  One of the channels is not working well 

1.  The stepper motor might be damaged or the cable connected to the PCB is broken. 

2.  The motor’s drive IC on the PCB might be out of condition. 

 

 

 

 

  9. Fixture Cleaning   

The cleaning of internal must be carried out periodically to optimize light output. Cleaning 

frequency  depends  on  the  environment  in  which  the  fixture  operates:  damp,  smoky  or 

Содержание LED-212RGB

Страница 1: ...lease read the instructions carefully before use 1A TABLE OF CONTENTS 1 Safety Instructions 2 Technical Specifications 3 Installation 4 How to set the unit 5 How to control the fixture 6 DMX512 Configuration 7 DMX512 Connections 8 Troubleshooting 9 Fixture Cleaning ...

Страница 2: ... directly at the LED light beam while the fixture is on Warning Please read the instructions carefully which includes important information about the installation operation and maintenance For power supply do not connect in series much more than 31 units use another mains supply for next 31 units 3A To prevent or reduce the risk of electrical shock or fire do not expose the unit to rain or moistur...

Страница 3: ...ction 12DMX output For DMX512 link use 3 5 pin XLR plug cable to link the next unit 5A 13DMX input For DMX512 link use 3 5 pin XLR plug cable to input DMX signal 14Mains input Connect to supply mains power 15Mains output Connect to supply mains power for the next unit 4 2 Main Function To select any of the given functions press the MENU button up to the required one is shown on the display Select ...

Страница 4: ...ode Press the MENU button up to when the is shown on the display Pressing ENTER button and the display will blink Use DOWN and UP button to select the auto show or show 1 or show 2 or show 12 Once the show has been selected press the ENTER button to confirm if you select show 1 or show 2 or show 12 you can press DOWN and UP button to select slowest or fastest press ENTER button to store or automat...

Страница 5: ... shown on the display Pressing ENTER button and the display will blink Use DOWN and UP button to select the no blackout or yes blackout mode Once the mode has been selected press the ENTER button to setup or automatically return to the main functions without any change after 8 seconds To go back to the functions without any change press the MENU button 9A again Led Display Press the MENU button up...

Страница 6: ...t s DMX input cable will have nothing connect it and the other fixtures will be set in slave mode automatically Their DMX input cables connect the last fixture DMX output cable daisy chain Any fixture can act as a Master or as a Slave C Easy Controller by CA 8 The easy remote control is used only in master slave mode There is a terminator for connect the easy controller inside the fixture By conne...

Страница 7: ...gestions for easy troubleshooting 13A A The fixture does not work no light 1 Check the connection of power and main fuse 2 Measure the mains voltage on the main connector B Not responding to DMX controller 1 DMX LED should be on If not check DMX connectors cables to see if link properly 2 If the DMX LED is on and no response to the channel check the address settings and DMX polarity 3 If you have ...

Страница 8: ...ration of Conformity We declare that our products lighting equipments comply with the following specification and bears CE mark in accordance with the provision of the Electromagnetic Compatibility EMC Directive 89 336 EEC EN55103 1 199601 2 EN55103 2 1996 EN61000 3 2 2000 A2 2005 EN61000 3 3 1995 A1 2001 A2 2005 Harmonized Standard EN 60598 1 2004 IEC 60598 1 2003 corrigendum 2004 Part 1 General ...

Страница 9: ...16A Innovation Quality Performance ...

Отзывы: