4.3 Changing the Lamp
Attention: The entire light path and lens of the luminaire must be thoroughly cleaned before
changing the bulb.
Do not use this lamp more than 6000 hours, using the lamp any longer than its set life could
seriously damage your unit. Periodically checking the lamp running time, when the lamp reaches
the 6000 hour mark, or close to it, we strongly suggest you switch the lamp out. Reset the lamp
time after you have replaced the lamp.
To replace the lamp:
1.
Ensure that the fixture is detached from power and has cooled down completely. It is a good
idea to allow the fixture to run for 10 minutes after the lamp has been turned off, so that the
cooling fans have time to works.
2.
Loosen the screws(A) on the head of the fixture and open the fixture head covers.
3.
Adjust the centrifugal screw(B). Unplug the leads of the lamp and lift the lamp out of its recess,
disconnect the lamp and connect a new lamp that must be the same type with the old one. And
then place the new lamp into the lamp recess.
Finally reinstall the head cover, fastening it securely before reapplying power.