very high-speed signal. Inadequate or damaged cables, soldered joints or corroded connectors
can easily distort the signal and shut down the system.
3.
The DMX output and input connectors are pass-through to maintain the DMX circuit, when
one of the units’ power is disconnected.
4.
Each lighting unit needs to have a DMX address to receive the data by the controller. The
address number is between 0-511 (usually 0 & 1 are equal to 1).
5.
The end of the DMX 512 system should be terminated to reduce signal errors.
6.
3 pin XLR connectors are more popular than 5 pins XLR.
3 pin XLR: Pin 1: GND, Pin 2: Negative signal (-), Pin 3: Positive signal (+)
5 pin XLR: Pin 1: GND, Pin 2: Negative signal (-), Pin 3: Positive signal (+), Pin4, Pin5 not used.
7.2 DMX Address Setting
If you use a universal DMX controller to control the units, you have to set DMX address from 1 to
512 so that the units can receive DMX signal.
Press the
MENU
button to enter menu mode, select
DMX Functions
, press the
ENTER
button to
confirm, use the
UP
/
DOWN
button to select
DMX Address
, press the
ENTER
button to confirm,
the present address will blink on the display, use the
UP
/
DOWN
button to adjust the address from
001 to 512, and press the
ENTER
button to store. Press the
MENU
button back to the last menu or
let the unit idle 7 seconds to exit menu mode.
Please refer to the following diagram to set the DMX address for the first 4 units
:
Channel Mode
Unit 1
Address
Unit 2
Address
Unit 3
Address
Unit 4
Address
5Channel
1
6
11
16
9Channel
1
10
19
28
15C