The I-210+ meter is designed for unattended operation over a long life. When the
meter or the site requires attention, the meter has features to facilitate the following
tasks:
• Enabling various modes of operation and enhanced functions already built
into the meter software.
• Displayable disk analog, instantaneous power, and RMS voltage capabilities,
for field calibration and testing.
• Application verification through limited site diagnostics.
This section provides information to aid qualified personnel when testing or
troubleshooting a meter.
Meter Accuracy Testing
The I-210+ meter includes provisions to verify the accuracy of calibration.
Test Mode
The I-210+ meter does not provide an independent test mode. Energy measured
during meter tests is accumulated normally.
Configuration Port
The optical configuration port is intended primarily for use in a controlled indoor
environment and is not shielded from ambient light. Bright light conditions may
interfere with field operation of the port. If field operation is required, a cover with
a shielded optical port is recommended.
Calibration
The meter is equipped with an infra-red light-emitting diode (IR- LED) for
calibration and a LCD with disk analog and test displays. The calibration IR-LED
is part of the configuration port as shown in the figure below.
The Configuration Port LED emits calibration pulses of infrared light unless the
meter detects the presence of OPTOCOM communications. Each calibration pulse
is equal to the value assigned to Kt (watt-hours). The duration of each output pulse
is approximately 25 milliseconds. The pulses are intended to be compatible with
the optical pickups provided by most watt-hour meter test equipment
manufacturers.
Содержание I-210+
Страница 1: ...I 210 Electronic Meter User Manual 132265 TUM Revision 1 www Aclara com...
Страница 2: ......
Страница 4: ......
Страница 8: ...vi I 210 User Manual...
Страница 12: ...2 I 210 User Manual...
Страница 40: ...30 I 210 User Manual AMI Modules...
Страница 42: ...32 I 210 User Manual...
Страница 44: ...34 I 210 User Manual Form 1S 2W 1 Form 1S 2W 1 Self contained 2 wire 1 phase 1 element...
Страница 45: ...I 210 User Manual 35 Chapter 7 Site Analysis Guides Form 2S 3W 1 Self contained 3 wire 1 phase 1 element...
Страница 46: ...36 I 210 User Manual Form 3S 2W 1 Form 3S 2W 1 Transformer rated 2 wire 1 phase 1 element...
Страница 47: ...I 210 User Manual 37 Chapter 7 Site Analysis Guides Form 3S 3W 1 Transformer rated 3 wire 1 phase 1 element...
Страница 48: ...38 I 210 User Manual Form 4S 3W 1 Form 4S 3W 1 Transformer rated 3 wire 1 phase 1 element...
Страница 49: ...I 210 User Manual 39 Chapter 7 Site Analysis Guides Form 12S 3W 1 Self contained 3 wire 1 phase 2 element...
Страница 50: ...40 I 210 User Manual Form 12S 3W N Form 12S 3W N Self contained 3 wire network 2 element...
Страница 51: ...I 210 User Manual 41 Chapter 7 Site Analysis Guides Form 25S 3W N Self contained 3 wire network 1 element...
Страница 52: ...42 I 210 User Manual Form 25S 3W N...
Страница 53: ...CHAPTER 8 DIAGRAMS ANSI Meter Diagrams Meter Outline Drawings...
Страница 54: ...44 I 210 User Manual...