Chapter 4
73
The right corner screen information gives you the available function keys and
the specified test number.
• Space
Enables/disables the item
• ESC
Exits the program
• F1
Help
• F2
Tests the selected item(s)
• Enter
Opens the available suboptions
• Test Times Indicates the number of tests to perform.
Note: The F1 and F2 keys function only after you finish configuring the
Test option.
PQA Diagnostic Program Error Code and Messages
\
Error Code
Message
Spare Part/Action in Sequence
System
16XX
Backup battery error
Backup battery
1XXX
CPU or Main board error
1. Reload BIOS default setting.
2. CPU
3. Main board
2XXX
Memory error
1. Reconnector CPU(IMM module)
2. DIMM
3. Main board
3XXX
Keyboard error
1. Reconnector Keyboard
2. Keyboard
3. Main board
4XXX
Video error
1. Main board
5XXX
Parallel Port error
1. Main board
6XXX
Serial port or Main board
error
1. Main board
7XXX
Diskette drive error
1. Diskette drive
2. Main board
8XXX
Hard disk error
1. Reload BIOS default setting.
2. Hard disk
3. Main board
9XXX
CD-ROM error
1. Reconnector CD-ROM cable
2. CD-ROM drive
3. Main board
10XXX
CPU or Main board error
1. CPU
2. Main board
11XXX
Pointing device error
1. Reconnector Keyboard
2. Keyboard
3. Main board
Содержание TravelMate 310
Страница 6: ...VI Appendix C Online Support Information 111 Index 113 Table of Contents ...
Страница 24: ...18 TravelMate 310 Service Guide ...
Страница 61: ...Chapter 3 55 7 Disconnect the modem board 8 Remove the system board from the upper case ...
Страница 62: ...56 TravelMate 310 Service Guide ...
Страница 80: ...74 TravelMate 310 Service Guide ...
Страница 82: ...76 TravelMate 310 Service Guide ...
Страница 94: ...88 EXTENSA 700 710 Service Guide ...
Страница 120: ...114 Index T Time setting in Setup Utility 21 U Utility BIOS Setup 20 ...