background image

System Adjustment 

Adjust the camera module:

 

Open  the  IWB calibration software, click “Installation and Debugging“ and 

choose “Tuning Webcam Image Mode”, the captured image by  the  camera 

module will be shown in the software interface. As shown in the pic below:

 

 

 

The captured projection image by the camera module should be completely 

included in the red guide frame interface. The image should be in proper 

direction and has more than 70% proportion in the whole software interface.

 

 

 

Содержание INTPJ-STK2

Страница 1: ...Smart Touch KitⅡ INTPJ STK2 UST INTPJ STK2 User s Guide ...

Страница 2: ... is easily accessible and located as close to the equipment user as possible When you need to disconnect power from the equipment be sure to unplug the power cord from the electrical outlet Warnings Do not install the camera module and the emitter under direct sunlight or reflected sunlight Please use the standard USB cable that came with our product and do not replace it with any other cable Do n...

Страница 3: ...Contents Introduction and Features 1 Hardware Installation 4 System Adjustment 8 Calibration Software 12 Gesture recognition introduction 21 Educational Software 22 Troubleshooting Guide 28 ...

Страница 4: ...or control Support Multi touch Up to ten people can write and erase simultaneously Portable and easy to install Just put the emitter above the projection screen by magnets or screws and mount the camera on the projector or the ceiling No need for professional technicians Our product can turn any flat surface like boards walls LCDs into finger touch screens Able to operate on any non transparent ob...

Страница 5: ...If any of the pieces is missing please notify your dealer Camera Emitter Mount Optional Mount Optional Security card Optional User s guide CD ROM Security card Optional Magnets Screws USB cables 6m and 12m Pointer Adapter Note The package contents may differ by regions 2 ...

Страница 6: ... Ratio 4 3 16 9 16 10 Projection ratio Ultrashort throw 0 21 shortest installation distance 0 45m Ultrashort throw 0 28 shortest installation distance 0 45m Depends on 80 projection screen aspect ratio 4 3 Laser Beam 2 Wavelength of Laser 940nm Output power for adapter 3 3V 2A Output power for camera 5V 0 5A Signal Refresh Rate 120fps Weight for package 2kg OS Requirement Win7 Win8 Win8 1 Win10 So...

Страница 7: ... the angle of the camera to ensure that it can be detected by the emitter as shown in the pic below 2nd installation method Bracket 2 Fix the camera to projector by using the matched black supporting bracket shown as the following image First fix the camera to the black supporting bracket with the matched screw via a screwdriver and make sure the camera should be at the right position shown as the...

Страница 8: ...g accessories Install the emitter module Install the module approximately 3cm above the projection surface and make it aligned with the center of the image The module is equipped with magnets allowing it to be attached to whiteboards directly If the module needs to be installed on a location where magnets cannot be used it can be fixed in place using 3M adhesive tapes or screws 5 ...

Страница 9: ...ection is used to connect the camera module and the emitter module Software Installation 1 Our software supports Win7 Win8 and Win10 OSes Put the software CD into the computer and start the software by double clicking Choose the language from the prompted message and select the throw ratio type according to the product model Note Select Throw Ratio0 21 for INTPJ STK2 UST and Throw Ratio0 28 for IN...

Страница 10: ... in several minutes 4 When the installation is complete an IWB icon will be added to the desktop Uninstall the Software 1 Open Control Panel 2 Click Program and Function 3 Right click the software and click Uninstall 4 Reboot the computer once the software has properly completed uninstallation 7 ...

Страница 11: ...Image Mode the captured image by the camera module will be shown in the software interface As shown in the pic below The captured projection image by the camera module should be completely included in the red guide frame interface The image should be in proper direction and has more than 70 proportion in the whole software interface 8 ...

Страница 12: ...e direction of the laser beam Turn Gear A clockwise the beam of red light will move away from projection board Turn Gear A counter clockwise it will approach the projection board Gear B used to adjust the horizontal direction of the beam of red light which is in the same direction of the laser beam Turn Gear B clockwise the right part of the red light beam will move away from the projection board ...

Страница 13: ...ion image and the distance between them is 50cm As shown in the pic below 2 Turn on the red light power button make the horizontal beam of red light reflect onto the magnets and you can see the clear red line between them by adjusting Gear A and Gear B As shown in the pic below 10 ...

Страница 14: ...t where the magnets stand the interval distance is better within 1mm When you use your finger to touch the whiteboard you can see the visible reflected red point As shown in the pic below 4 After that turn the red light button off once calibration is completed and close the top cover 11 ...

Страница 15: ...n the calibration program to start the camera image Stop Close the camera image then no more touch functions Parameter Setting Software parameters setting Auto Mask Clutter Auto shields the interference point from the outside environment After the auto mask clutter the auto calibration can be continued 12 ...

Страница 16: ...tion it doesn t need to be clicked manually The calibration will finish within 5 seconds and it realizes the touch function after successful calibration Lightspot Sampling The lightspot sampling can only be conducted after manual calibration or auto calibration which makes our product adapting to current usage environment and user experience will be better Disable Optical Pen Control After choosin...

Страница 17: ...ibration The larger the value is the brighter the brightness is Light Gray 0 255 refers to the black and white checkerboard overall picture contrast presented during automatic calibration process by the calibration software The larger the value is the greater the contrast between the black area and the white area in the black and white Checkerboard Video record Record the auto calibration process ...

Страница 18: ...spot 3 7 refers to the sensitivity of palm gesture The lower the value is the better the sensitivity is Start All GLBoard Gesture refers to the switcher of GLBoard gesture Eraser in multiples of spot 3 7 refers to the sensitivity of palm eraser gesture The lower the value is the better the sensitivity is 15 ...

Страница 19: ...ptional Process In Exceptional Process you can add exceptions Click Add exception to select the process to be added to Exceptional List Select the process added in Exceptional List and then Gesture recognition can be applied to the program you want to use The user can start and close any gesture recognition based on their requirements This function is setting gesture recognition for third party so...

Страница 20: ...ection screen with your finger or the IR Pen There will be four light spots each with a size of over 3x3 pixels 3 Click Manual Calibration 25 dots 36 dots on the operation menu The projected image on the screen will switch to the Manual Calibration screen and icon will be displayed at the top left of the screen 4 Press the 25 36 dots on the screen using your finger or the IR Pen 17 ...

Страница 21: ...he operation menu The image being projected will switch to the automatic calibration screen 2 After five seconds calibration will be complete and the screen will return to displaying the image originally being projected Open the calibration software again if below image is displayed on the screen the calibration has completed successfully Note If the Auto Calibration has failed please refer to the...

Страница 22: ...click lightspot sampling and the projection image will change to lightspot sampling interface Use finger or IR pen to touch the red square and continue the next one when the red square changes to green Installation and Debugging Click Installation and Debugging menu 19 ...

Страница 23: ...e finger to touch 4 corners Normal Usage Image Mode After the calibration all operations can be done by the finger instead of the mouse Mouse click mouse then you can only do single touch in Windows Touch Pad click touch pad then you can do multi touch in Windows Touch Pad Aspect Ratio The default mode is auto selected When the deviation of touch pad accuracy is more than 3cm you can try following...

Страница 24: ...Gesture recognition introduction Gesture recognition in Windows Gesture recognition in educational software GLBoard 21 ...

Страница 25: ...ram the interface includes three areas shown as the following Function of each button on the toolbar Icon Name Function Start menu Open the menu list Resource Local resource Click to find many pictures Network resource Click to search any picture you like on the web New page There are four options Work area picture or text editing Toolbar 22 ...

Страница 26: ...quare and circle Import picture Insert pictures from your computer Import text Insert text frame then edit the words Fill Fill geometric shapes with different colors Select stroke Select the handwriting on the page and drag and zoom Select picture Move geometric shapes text and pictures Zoom in and out Zoom in or zoom out the picture Pen color Adjust color of the pen Fill color Choose the color to...

Страница 27: ...hen you click to go back to the desktop GLBoard will appear as a floating toolbar Icon Name Function Windows Back to the desktop Pen Write like a ball pen New page Open a new white page New page Open a new black page Back Go back to the previous page Forward Forward to next page Eraser Erase by stroking 24 ...

Страница 28: ...e page Close Close GLBoard Width Set stroke width Start Menu List Menu Submenu Function Description File New Create a blank file If any file has not been saved before a save message will be shown Open Open an existed PPT PDF PTS file Save Save the file under editing Save As Save as a new file Export Export as an image file to Windows 25 ...

Страница 29: ...se the Desktop as background Other background color Choose the background color yourself Insert a hyperlink Insert a hyperlink that could open a linked page directly Cut Cut the selected word and image Copy Copy a file from one place to another place while the old one remained Paste Paste the copied and cut content directly Delete Delete the selected word or image from the system User management N...

Страница 30: ...as the Windows Calculator Handwriting recognition Handwriting input see gesture recognition introduction Screen Recording Record the activities on the GLBoard as a video file System Setup Startup setting and page setting etc Select all strokes Select all strokes in the screen area Clear Clear all strokes in the screen area PageList Show all pages of GLBoard in a list Slide page navigation Show the...

Страница 31: ...lem with the connection please reconnect using another USB port If there is no problem with the USB port Please reconnect using another USB cable If there is no problem with the connection please reconnect using another camera Please contact the factory if the problem persists When auto calibration is successful there is inaccuracy with mouse pointer and finger or IR pen Open Tuning Webcam Image M...

Страница 32: ...ue of auto calibration average image brightness down to 40 the value of Light Gray up to 250 If the overall brightness is low please adjust the value of auto calibration Average Brightness up to 140 the value of Light Gray up to 250 Please contact the factory or do manual calibration if the problem persists Inaccurate performance on top corners or non smooth writing Open the calibration software I...

Отзывы: