5.5. Chromaticity
The color chromaticity is measured by a photometer (CA-210) at 1680x1050/60Hz mode and full white square pattern
with contrast/brightness in default value. The x and y co-ordinates for 9300K, 8200K, 7500K, 6500K and 5000K. Preset
mode shall be as below:
9300K Preset :
0.253 x 0.313 ; 0.268 y 0.328
≦ ≦
≦ ≦
7500K Preset :
0.269 x 0.3
≦ ≦
29 ; 0.285 y 0.3
≦ ≦
45
6500K Preset :
0.283 x 0.343 ; 0.299 y 0.359
≦ ≦
≦ ≦
5000K Preset: 0.314 x 0.
≦ ≦
375 ; 0.329 y 0.3
≦ ≦
89
8200K Preset: 0.262 x 0.
≦ ≦
322 ; 0.277 y 0.3
≦ ≦
37
5.6. Brightness
The uniformity is determined by using a photometer (CA-210) to measure luminance on the center of screen after at
least 30 minutes warm up. It shall be test at 1680x1050/60Hz mode and full white square pattern with contrast at
default and brightness at max conditions. The values specified are at an approximate distance 20 cm from the LCD
surface and at 0 viewing angle. The brightness at 6500K Preset mode shall be 240 cd/m² min. (M201EW02 V1)
Note: Per panel specification, over the life of the product, variation of parameters specification Panel
specification shall be maintained within reasonable limits. Check supplier quality inspection
criteria for the detail information.
6. Environmental
Requirements:
6.1. Temperature Ranges
Operating Temperature (guaranteed functional performance): 0oC to 50oC
Operating Temperature (guaranteed optical performance): 5oC to 35oC
Shipping Temperature: -20oC to 60oC
Storage Temperature: -20oC to 60oC
6.2. Humidity
Operating (non-condensing) : 10% to 80%
Shipping (non-condensing) :
5% to 90%
Storage (non-condensing) :
5% to 90%
6.3. Altitude
Operating
0 to +12,000 feet [3,658m].
Equivalent to 14.7 to 10.1 psia.
Shipping (Non-Operating) 0 to +40,000 feet [12,192m].
Equivalent to 14.7 to 4.4 psia.